Adc, Pllc, Pediatrics At Cedar Bend, The

CLIA Laboratory Citation Details

3
Total Citations
11
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 45D0505253
Address 2400 Cedar Bend, Austin, TX, 78758
City Austin
State TX
Zip Code78758
Phone512 901-4366
Lab DirectorVANDANA RAWAL

Citation History (3 surveys)

Survey - March 11, 2025

Survey Type: Standard

Survey Event ID: R92W11

Deficiency Tags: D0000 D5821 D6045 D0000 D5821 D6045

Summary:

Summary Statement of Deficiencies D0000 The laboratory was surveyed and found to be in compliance with the Conditions of the CLIA regulations found at 42 CFR 493.1 through 493.1780, and recertification is recommended. Standard level deficiencies were cited. D5821 TEST REPORT CFR(s): 493.1291(k) (k)When errors in the reported patient test results are detected, the laboratory must do the following: (k)(1) Promptly notify the authorized person ordering the test and, if applicable, the individual using the test results of reporting errors. (k)(2) Issue corrected reports promptly to the authorized person ordering the test and, if applicable, the individual using the test results. (k)(3) Maintain duplicates of the original report, as well as the corrected report. This STANDARD is not met as evidenced by: Review of patient test reports and interview showed the laboratory failed to correctly tabulate the test report to show it was a corrected report in the electronic medical record (EMR) for one of one complete blood count (CBC) corrected reports reviewed. Findings follow. A. Review of patient test reports showed the laboratory issued a CBC test report for patient 8X800617048 on 01/23/2025 when no quality control (QC) had been performed on the Sysmex XP-300. B. Interview with the nursing supervisor on March 11, 2025 at 1300 hours acknowledged the replaced report should have said "corrected" so that staff would know there was a second corrected report. She said she pulled the original report not knowing there was a corrected report because the amended report was not identified as "corrected" when it was put into the EMR. D6045 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(7) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (b)(7) Identifying training needs and assuring that each individual performing tests receives regular in-service training and education appropriate for the type and complexity of the laboratory services performed; This STANDARD is not met as evidenced by: Based on review of the laboratory's policies and procedures, documentation of training records, pre-survey paperwork, and interview, the Technical Consultant failed to ensure 4 of 8 new testing personnel had the appropriate documentation of training on the Sysmex XP-300 for the complete blood count (CBC). Findings follow. A. Review of the laboratory's policy and procedure titled General Laboratory Polices (Moderately Complex Lab), approved 03/04/2025, under Laboratory Personnel stated, "Testing personnel must upon hire, supply the laboratory with proof of their highest level of education (minimum High School Diploma or GED). Copies of transcripts or diplomas are acceptable (not nursing licenses, medical assistant certificates, etc.). The laboratory documents the training of testing personnel for all applicable laboratory procedures." B. Review of documentation of training records showed no documentation for the following new testing personnel as listed on the CMS Form 209 with their hire/start dates from the pre-survey paperwork titled "Laboratory Personnel": 1. #2 02/12/2024, 2. #4 09/30/2024, 3. #8 10/2024, and 4. #11 10/21 /2024. C. Interview with the Technical Consultant on March 11, 2025 at 0940 hours confirmed the findings. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 20, 2023

Survey Type: Standard

Survey Event ID: NXL511

Deficiency Tags: D5413 D1001 D5413 D0000

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representatives at the exit conference. The facility was found to be in compliance with applicable Conditions in the CLIA program, and recertification is recommended. D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: I. Based on review of manufacturer's instructions, observation, and interview, the laboratory failed to follow manufacturer's instructions for reading Multistix 10 SG urine dipsticks used to test Protein, Blood, Leukocytes, Nitrite, Glucose, Ketone, pH, Sepcific Gravity, Bilirubin, and Urobilinogen for one of one observation. Findings follow. A. Review of the Multistix 10 SG package insert, 11306391 Rev A 07-2017, under Procedure stated, "7. If reading visually: Compare each test pad to the corresponding row of color blocks on the bottle label. Read each pad at the time shown on the label, starting with the shortest time. Hold the strip close to the color blocks and match carefully." B. Review of the multistick bottle showed glucose and bilirubin were to be read at 30 seconds; ketone was to be read at 40 seconds; specific gravity was to read at 45 seconds; and blood, pH, protein, urobilinogen, nitrite, leukocytes were to be read at one minute. C. During a tour of the laboratory, the surveyor observed testing personnel #1, as listed on the CMS form 209, performing patient testing on January 18, 2023 at 1030 at Pod #3. Testing personnel #1 first dipped the dipstick in the urine cup, set the strip down on a pad on the counter, and then set the timer for 2 minutes, walked away to get a printed patient label, returned and began to read the strip with 52 seconds left on the timer, picked up the strip and held it and completed the readings. The patient tested was Account # 8x703002027. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- By the time she began to read the strip, the time elapsed for glucose and bilirubin was 68 seconds. The readings for glucose, bilirubin and ketones were made while the strip was still on the counter, about a foot from the bottle. D. Interview with the Technical Consultant on January 18, 2023 at 1045 confirmed the findings. II. Based on review of the manufacturer's instructions, training records, and interview, the laboratory failed to provide documentation of training for the Abbott ID NOW Covid-19 test for two of 13 testing personnel. Findings follow. A. Review of the ID NOW Covid-19 product insert, IN192000 Rev 1 2022/05, under Intended Use stated, "ID NOW Covid- 19 2.0 is intended for use by trained operators who are proficient in performing tests using the ID NOW Instrument. The ID NOW Covid-19 2.0 assay is only for use under the Food and Drug Adminitration's Emergency Use Authorization." B. Review of the Testing Personnel Training Record for testing personnel 1) #6 and 2) #11 showed the line for Covid-19 training was blank for the date, employee initials, and trainer initials. C. Interview with testing personnel #3 on January 18, 2023 at 0935 hours acknowledged she had that. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of manufacturer's instructions, humidity charts, patient testing logs, and interview the laboratory failed to monitor the humidity within the Sysmex XP-300 manufacturer's specifications for performing CBC (Complete Blood Count) testing for 15 of 108 days reviewed for Pod #3, Sysmex #2. Findings follow. A. Review of the Sysmex XP-300 Instructions for Use, AU553517 November 2013, at 14. Technical Information, 14.1 Specifications, stated, "Operating Environment... Relative humidity: 30% to 85%". B. Review of the laboratory's Room Temperature/Humidity Log for Pod #3, Sysmex #2, SN A3089, had an acceptable humidity of 30-85%. Review of logs from August 2022 - December 2022 showed the laboratory exceeded the manufacturer's range on 14 of 108 days reviewed. C. Review of the Daily Testing Log showed the CBCs tested: Date % Humidity Accession#/Account # 1. 10/03/22 25 10384577 10384043 10384248 10384550 2. 10/04/22 28 10385669 10385297 10385553 10384733 3. 10/05/22 28 10386584 10386297 4. 10/18/22 29 10397431 10397958 5. 10/19/22 28 10398853 10399170 6. 10/20/22 27 10400400 7. 11/14/22 25 10421518 10421847 10422026 8. 11/15/22 28 10422805 10423448 9. 11/16/22 28 8x800317380 10424680 10424699 10424710 10424816 10424132 10424294 10424308 10. 11/17/22 27 10425564 11. 11/18/22 29 no patients 12. 12/01/22 25 13. 12/22/22 29 8x800302299 10453180 10452827 10453177 14. 12/28/22 28 10455619 10455642 8x702991620 10455795 8x800411586 D. Interview with Technical Consultant #1 on the CMS form 209, on January 18, 2024 at 1100 hours in the office confirmed the findings. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 5, 2021

Survey Type: Standard

Survey Event ID: OB9H11

Deficiency Tags: D3011

Summary:

Summary Statement of Deficiencies D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on observation and interview, the laboratory failed to observe safety procedures by storing 9 cans of apple juice for patient consumption in 3 of 3 laboratory refrigerators. Findings follow. A. During a tour of the laboratory on August 5, 2021, the following refrigerators were found to contain apple juice: 1. Laboratory 1 refrigerator at 1010 hours 3 cans of apple juice stored in the same refrigerator as CBC (Complete Blood Count) controls, glucose reagents, and vaccines; 2. Laboratory 2 West refrigerator at 1020 hours 3 cans of apple juice stored in the same refrigerator as glucose reagents and vaccines; 3. Laboratory 2 East refrigerator at 1025 hours 3 cans of apple juice stored in the same refrigerator as CBC controls, glucose reagents and vaccines. B. Interview with the LVN Clinical Supervisor on August 5, 2021 at 1010 hours in the laboratory confirmed the apple juice was for the patients. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access