Adrian L Connolly Md Llc

CLIA Laboratory Citation Details

2
Total Citations
13
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 31D0980863
Address 101 Old Short Hills Road, West Orange, NJ, 07052
City West Orange
State NJ
Zip Code07052
Phone(973) 731-9131

Citation History (2 surveys)

Survey - May 9, 2023

Survey Type: Standard

Survey Event ID: HI4911

Deficiency Tags: D5217 D5401

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM), lack of Biannual Assessment (BA) records and interview with the Testing Personnel (TP), the laboratory failed to verify the accuracy and reliability of Mart-1 Histopathology testing twice a year in the calendar year 2022. The finding includes: 1. There was no evidence that a BA was performed in 2022. 2. The TP confirmed on 5/9/23 at 10:05 am that the laboratory did not verify the accuracy of Mart-1 Histopathology testing twice a year. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM), and interview with the Testing Personnel (TP), the laboratory failed to have a procedure for Mart-1 histopathology Biannual Assessment (BA) on the date of survey. The TP confirmed on 5/9/23 at 11:00 am that the laboratory did not have the aforementioned procedure. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 27, 2018

Survey Type: Standard

Survey Event ID: 670411

Deficiency Tags: D5411 D5413 D5415 D5417 D5417 D5429 D5805 D6102 D5429 D5805 D6102

Summary:

Summary Statement of Deficiencies D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on surveyor review of the MART-1 Manufacturers Package Insert (MPI), observation of the slides and interview with the Testing Personnel (TP), the laboratory failed to follow the MPI instructions for MART-1 slides at the time of the survey. The finding includes: 1. The MPI stated that slides must be positively charged but the StatLab colorview adhesion slides used in the laboratory did not state they were positively charged. 2. The date the slides were opened was not documented. 3. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:10 am that the MPI was not followed. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on surveyor review of temperature records and interview with the Testing Personnel (TP) the laboratory failed to record the temperature of the heat block used for MART-1 tests from 9/22/16 to the date of the survey. The findings include: 1. The temperature of the heat block used in MART-1 Histopathology testing must by at 60 degrees. 2. There was no temperature chart for the heat block. 3. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:45 am temperature of the heat block was not recorded. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on surveyor observation of the Histopathology reagents and interview with the Testing Personnel (TP), the laboratory failed to appropriately label the reagents used for Histopathology tests with pertinent information required for proper use on the date of the survey. The findings include: 1. 70% Alochol was prepared in the laboratory and wasn't labeled as to its storage requirements, preparation and expiration dates. 2. Xylene was in a pour off bottle and was not labeled to indicate: a. Concentration b. Storage requirements c. Preparation and expiration dates. 3. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:35 am all reagents were not labeled appropriately. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on surveyor observation of reagents and interview with the Testing Personnel (TP), the laboratory failed to check the expiration date for reagents used for Hisotpathology tests on the date of the survey. The findings include: 1. Acetone and Toludin Blue were expired. 2. Approximately 8 to 10 patients were run once a month. 3. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:10 am that the laboratory had expired reagents. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on surveyor review of the Maintenance Records (MR) and interview with the Testing Personnel (TP), the laboratory failed to replace the filter on the Air Filtronix Fume Hood (FH) used in Histopathology testing from 10/17/16 to the day of the survey. The finding includes: 1. The paperwork on the FH stated the filter is to be replaced every six months but the last date it was changed was 10/17/16. 2. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:30 am maintenance was not performed. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on surveyor review of the Final Report (FR) and interview with the Testing Personnel (TP), the laboratory failed to report Histopathology test results accurately from 9/22/16 to the date of survey. The finding includes: 1. The laboratory performed MART-1 a non Food and Drug Administration cleared tests and there was no statement stating "The performance characteristics of this test were determined by (Laboratory Name). It has not been cleared or approved by the U.S. Food and Drug Administration" on FR. 2. The TP #1 listed on the CMS 209 confirmed on 9/27/18 at 12:30 pm that MART-1 test were not reported accurately. D6102 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(12) The laboratory director must ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results. This STANDARD is not met as evidenced by: Based on surveyor review of the Personnel Records (PR) and interview with the Testing Personnel (TP), the Laboratory Director failed to ensure that one of two TP had appropriate education prior to patient testing from January 2018 to the date of survey. The TP #1 listed on CMS form 209 confirmed on 9/27/18 at 10:20 am that education was not documented. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access