Citation History (3 surveys)

Survey - September 17, 2024

Survey Type: Standard

Survey Event ID: Z3R611

Deficiency Tags: D5471

Summary:

Summary Statement of Deficiencies D5471 CONTROL PROCEDURES CFR(s): 493.1256(e)(1)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e)(i) Check each batch (prepared in-house), lot number (commercially prepared) and shipment of reagents, disks, stains, antisera, (except those specifically referenced in 493.1261 (a)(3)) and identification systems (systems using two or more substrates or two or more reagents, or a combination) when prepared or opened for positive and negative reactivity, as well as graded reactivity, if applicable. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on record review and staff interview the laboratory failed to document quality control (QC) checks on new lots and shipments of Dermatophyte Test Medium (DTM) for positive and negative reactivity in the subspecialty of mycology. Findings Include: 1. Record review on 09/17/2024 of the laboratory's QC binder revealed lack of documentation of positive and negative reactivity checks for the new lot numbers and shipments of DTM. 2. Record review on 09/17/2024 of the laboratory's 'Procedure of Obtaining Control Cultures' policy revealed that "Cultures for Westport are received in Trumbull, quality control done in Trumbull, then sent to Westport on a day that an employee is doing a split shift between Trumbull and Westport'. 3. Staff interview on 09/17/2024 at 9:50AM with the office supervisor confirmed the above findings. 4. The laboratory performs 59 DTM cultures annually in the subspecialty of mycology. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 29, 2022

Survey Type: Standard

Survey Event ID: VL4J11

Deficiency Tags: D5407 D5413 D5411

Summary:

Summary Statement of Deficiencies D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to ensure changes to the fungal culture procedure were updated, approved and signed by the laboratory director in the subspecialty of mycology prior to patient testing. Findings include: 1. Record review on 3/29/2022 of the laboratory's 'Obtaining/entering/reading /documenting results overview' procedure revealed: a. The procedure for 'taking /obtaining a fungal culture' was to inoculate the fungal culture media Sabouraud Dextrose Agar. b. After 2 weeks the provider does a visual reading of the Sabouraud Dextrose agar vial and results a positive or negative culture. c. Approval date of the procedure was 7/31/2018. 2. Surveyor observation on 3/29/2022 at 10:10 AM of the laboratory's fungal culture media revealed 2 boxes of Remel Dermatube Dermatophyte Test Medium (DTM), Lot #: 367893 exp 9/22/2022 in use. 3. Record review on 3/29/2022 of the Remel DTM manufacturer product insert revealed to examine the media at regular intervals for a red color development. 4. Record review on 3/29/2022 of the laboratory's 'Form 21: Laboratory Test Requisition and Report Log' revealed: a. 2 shipments of Sabouraud Dextrose Agar with date received 6/20/18 and 1/24/2019. b. 4 shipments of DTM with date received 1/17/2020, 9/4/2020, 10/21 /2021 and 2/16/2022 (Lot #367893). 5. Staff interview with the laboratory director (LD) on 3/29/2022 at 10:30 AM confirmed the above findings. The LD disclosed he /she was aware the laboratory switched to DTM at some point and a positive result on DTM is the color change to red but did not update the procedure. 6 The laboratory performs 212 fungal cultures annually in the subspecialty of mycology. D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on surveyor observation, record review and staff interview, the laboratory failed to follow the manufacturer instructions for proper storage of dermatophyte test medium (DTM) used for fungal cultures in the subspecialty of mycology. Findings include: 1. Surveyor observation on 3/29/2022 at 10:10 AM revealed the following: a. 2 boxes of uninoculated Remel DTM located on a shelf in a storage closet at room temperature. b. DTM package label identified a storage condition of 2 to 8 degrees Celsius until ready to use. 2. Staff interview with the laboratory director on 3/29/2022 at 10:30 AM confirmed the above findings. 3. The laboratory performs 212 fungal cultures annually in the subspecialty of mycology. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to follow manufacturer instructions to monitor and document temperatures for proper testing performance of fungal cultures in the subspecialty of mycology. Findings include: 1. Record review on 3/29/2022 of the Remel Dermatophyte Test Media (DTM) product insert revealed to incubate DTM in ambient air at 25-30 degrees Celsius for up to 14 days. 2. Record review on 3/29/2022 of laboratory maintenance records revealed the lack of documentation of room temperature readings where inoculated DTM are stored during the 14 day testing period. 3. Staff interview with the laboratory director on 3/29/2022 at 10:30 AM confirmed the above findings. 4. The laboratory performs 212 fungal cultures annually in the subspecialty of mycology. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 24, 2018

Survey Type: Standard

Survey Event ID: HI5N11

Deficiency Tags: D6053

Summary:

Summary Statement of Deficiencies D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to assess and document new testing personnel competency to perform fungal cultures in the subspecialty of mycology twice in the first year of performing patient testing. Findings include: 1. Record review of the CMS Laboratory Personnel Report 209 form on 7/24/18 revealed 1 new testing personnel was hired since the last survey. 2. Record review of the testing personnel competency records on 7/24/18 revealed the semiannual assessment for 1 of 1 new testing personnel was not available. 3. Record review of the laboratory's procedure manual on 7/24/18 revealed the lab did not have a policy in place to train and perform semiannual competency in the first year and annual thereafter for new testing personnel. 4. Staff interview with the laboratory director on 7/24/18 at 9:45 AM confirmed the above findings. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility