Advanced Cosmetic Surgery & Dermatology

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 05D0615137
Address 276 Kingsbury Grade Ste 101, Stateline, NV, 89448
City Stateline
State NV
Zip Code89448
Phone(775) 588-5000

Citation History (3 surveys)

Survey - July 21, 2025

Survey Type: Standard

Survey Event ID: XX1M11

Deficiency Tags: D5217 D0000 D5417

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was created as a result of an on-site CLIA recertification survey conducted at your facility on July 21, 2025. The findings and conclusions of any investigation by the Division of Public and Behavioral Health shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state, or local laws. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on a review of the 2024 laboratory records for the twice per year verification of accuracy for KOH testing, and an interview with the office manager, the laboratory failed to ensure that the twice per year verification of accuracy was performed for each provider performing KOH testing in the laboratory. Findings include: 1. Testing personnel number one on the CMS 209 form did not have documentation of accuracy checks in 2024. 2. An interview with the office manager on July 21, 2025 at approximately 12:00 PM confirmed these findings. The laboratory performs approximately 7 mycology and parasitology tests annually. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) (d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on observation of the testing supplies available during a walk-through of the facility on July 21, 2025, at approximately 12:30 PM, and an interview with the office manager, the laboratory failed to ensure that testing supplies available for use were not expired. Findings include: 1. The laboratory had expired KOH testing supplies available for use. The KOH bottle (lot number 1120) expired on April 30, 2023. There were no KOH bottles available that was not expired. 2. An interview with the office manager confirmed these findings. This is a repeat deficiency cited during the recertification survey performed on December 15, 2023. The laboratory performs approximately 7 mycology and parasitology tests annually. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 15, 2023

Survey Type: Standard

Survey Event ID: JVYM11

Deficiency Tags: D5203 D5417 D0000 D5413 D6094

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was created as a result of an on-site CLIA recertification survey conducted at your facility on December 15, 2023. The findings and conclusions of any investigation by the Division of Public and Behavioral Health shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state, or local laws. D5203 SPECIMEN IDENTIFICATION AND INTEGRITY CFR(s): 493.1232 The laboratory must establish and follow written policies and procedures that ensure positive identification and optimum integrity of a patient's specimen from the time of collection or receipt of the specimen through completion of testing and reporting of results. This STANDARD is not met as evidenced by: Based on a random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023, a review of the laboratory's example of how to complete the Mohs map, and an interview with the office administrator, the laboratory failed to ensure that the Mohs maps were correctly completed in order to ensure positive identification of the patient specimens from the time of collection of the specimen through completion of the testing. Findings include: 1. A random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023 found that the laboratory failed to ensure that the date of surgery was consistent between the Mohs tracking log, Mohs map, and slides. The date of surgery was recorded as October 31, 2023 on the Mohs tracking log, and October 30, 2023 on the slides and Mohs map for one of six patients (initials GT). 2. A random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023 found that the laboratory failed to complete the Mohs map as indicated by the example included with the director approved policies and procedures. The Mohs Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- maps for two of six patients (initials MM and PD) did not have the number of levels of tissue sections identified on the maps. 3. An interview with the office administrator at approximately 2:30 PM on December 15, 2023, confirmed these findings. The laboratory performs approximately 5,559 histopathology tests annually. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on a random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023, a review of the temperature logs for the refrigerator and cryostat, a review of the director approved policies and procedures, and an interview with the office administrator, the laboratory failed to ensure that refrigerator temperatures were recorded daily and the cryostat temperatures were recorded on Mohs surgery days. Findings include: 1. A review of the temperature logs for the refrigerator revealed that the temperatures were not recorded daily for nine of nine months, as required by the director approved procedure titled, "7C3 Lab QC Procedures: CLIA checks." 2. A random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023, revealed that the temperatures were not recorded on the six days of Mohs surgery that were randomly reviewed. The cryostat temperature is to be recorded on days on MOHS [sic] days per the director approved procedure titled, "7C3 Lab QC Procedures: CLIA checks." 3. An interview with the office administrator on December 15, 2023, at approximately 3: 00 PM confirmed these findings. The laboratory performs approximately 5,559 histopathology test annually. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on observation and an interview with the office administrator, the laboratory failed to ensure that laboratory reagents were discarded by their expiration dates. Findings include: 1. During the on-site survey on December 15, 2023, it was observed that two containers of Eosin-Y Alcoholic reagent with expiration dates of 2-31-2023 [sic] and 11-30-2023 were available for use. 2. An interview with the office administrator on December 15, 2023 at approximately 3:00 PM confirmed these findings. The laboratory performs approximately 5,559 histopathology tests annually. D6094 LABORATORY DIRECTOR RESPONSIBILITIES -- 2 of 3 -- CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on observation, review of laboratory records, and interview with the practice manager, theoffice administrator failed to ensure that the quality assessment (QA) programs identified failures in quality as they occur. Findings include: 1. The QA program failed to identify that specimen identity was not maintained throughout the preanalytic, analytic and postanalytic phases of testing. A random patient audit of six Mohs patients tested between the dates of February 14, 2022 and October 31, 2023, found that the laboratory failed to ensure that the Mohs maps were correctly completed in order to ensure positive identification of three of six patient specimens from the time of collection of the specimen through completion of the testing. Refer to D5203 2. The QA program failed to identify that expired reagents were available for use. Eosin-Y Alcoholic reagent with expiration dates of 2-31-2023 [sic] and 11-30- 2023 were found available for use. Refer to D5417 3. The QA program failed to identify that temperatures for the refrigerator and cryostat were not being recorded as indicated by the director approved procedure. A review of the temperature logs for the refrigerator and cryostat found that the laboratory failed to ensure that refrigerator temperatures were recorded daily and the cryostat temperatures were recorded on Mohs surgery days. Refer to D5413 4. These findings were confirmed by the office administrator during the on-site survey on December 15, 2023 at approximately 3:00 PM. The laboratory performs approximately 5,559 histopathology tests annually. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 10, 2019

Survey Type: Standard

Survey Event ID: U7HY11

Deficiency Tags: D0000 D5203

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was created as a result of an on-site CLIA recertification survey conducted at your facility on June 10, 2019. The findings and conclusions of any investigation by the Division of Public and Behavioral Health shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state, or local laws. D5203 SPECIMEN IDENTIFICATION AND INTEGRITY CFR(s): 493.1232 The laboratory must establish and follow written policies and procedures that ensure positive identification and optimum integrity of a patient's specimen from the time of collection or receipt of the specimen through completion of testing and reporting of results. This STANDARD is not met as evidenced by: Based on review of nine Mohs and biopsy cases and medical charts and interview with the practice manager and laboratory personnel, the laboratory failed to follow written policies and procedures to ensure positive identification of patient's specimen from the time of collection through completion of testing and reporting of results. Findings include: A sample survey of nine Mohs and biopsy cases revealed that the date of birth (DOB) used as part of the two patient identifier established by the laboratory did not match on the Mohs Operative Report and the DOB on the Mohs Surgery Note, patient's medical chart, and the Mohs slides on one of the cases reviewed. On the Mohs Operative Report, the DOB was 1/01/1986 and on the Mohs Surgery Note, medical chart and the Mohs slides, the DOB was 1/02/1986. The practice manager and laboratory personnel confirmed the finding during the on-site survey on 6/10/19 at approximately 3:00 PM. The laboratory performs approximately 6,530 histopathology tests annually. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access