Adventhealth Lab

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 10D0289356
Address 13100 Fort King Rd, Dade City, FL, 33525
City Dade City
State FL
Zip Code33525
Phone(352) 521-1100

Citation History (1 survey)

Survey - July 19, 2024

Survey Type: Standard

Survey Event ID: J5BL11

Deficiency Tags: D5411 D0000

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA validation survey was conducted at Adventhealth Lab on 07/15 /2024-07/17/2024. The laboratory was surveyed under 42 CFR Part 493 CLIA requirements. Standard deficiencies cited are as follows: D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on observation, interview, and records review, the laboratory failed to follow the manufacturer's instructions and the laboratory's stated performance specifications for Urine Fentanyl from 08/28/2023 to 07/15/2024. Findings Included: During a tour of the laboratory on 7/15/2024 at 2:00 PM an opened bottle of Fentanyl lot #22010106 with expiration date of 2024-04-30 Calibration reagent was observed in reagent refrigerator. Technical Supervisor E (TS #E) and Technical Supervisor C (TS#C) confirmed on 07/15/2024 at 2:25 PM the Fentanyl Calibration reagent lot #22010106 expired on 2024-04-30 had been used to perform Calibration for Fentanyl testing on 06 /12/2024 with expired reagent. Review of the manufacturer's instructions for Fentanyl testing stated Calibration was to be performed every 30 days. Review of the laboratory Fentanyl Procedure approved by the Lab Director 08/15/2023 Calibration was to be performed every 30 days and that the Calibration stability was the stated expiration. Review of Calibration log from 08/28/2023 to 07/15/2024 documented Calibration was performed 8/28/2023, 09/29/23 (32 days later), 11/15/2023 (47 days later), 12/16/2023 (31 days later), 12/23/2023 (7 days later), 01/22/2024 (30 days later), 03/19/2024 (57 days later), 04/05/2024 (17 days later), 6/12/2024 (68 days later), and 07/15/2024 (33 days later). TS #E and TS # C both confirmed on 07/15 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- /2024 at 4:30 PM patient Fentanyl testing had not been performed following the manufacture's instruction and laboratory's procedure for performance specifications regarding the frequency of Calibration and the stability of Calibration reagent. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access