Aeon Technologies, Llc

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 21D2183615
Address 1 Technology Drive #1600, Frostburg, MD, 21532
City Frostburg
State MD
Zip Code21532

Citation History (2 surveys)

Survey - May 19, 2023

Survey Type: Standard

Survey Event ID: POD111

Deficiency Tags: D5215 D5775 D6127 D5421 D6092

Summary:

Summary Statement of Deficiencies D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on review of proficiency testing (PT) records and interview with the laboratory director (LD), the laboratory failed to document a self-evaluation of PT scores that were ungraded by the College of American Pathologists (CAP) PT program to verify accuracy. Findings: 1. The laboratory was enrolled with CAP in three annual events (A, B, and C) for hematology auto differentials (FH3) and two annual events (A and B) for clinical microscopy (CM). 2. The CAP PT program used reason codes when a PT sample was not graded. 3. Reason code [27] was for "Lack of participant or referee consensus" and was used for "Urine Sediment ID" for sample CMP-05 in the CM-A 2023 PT event. 4. Reason code [26] was for "Educational challenge" and was used for "Blood Cell ID Ungraded" for samples BCP-06 through BCP-10 in the FH3-A 2023 PT event. 5. There was no documentation indicating that the ungraded PT results were compared with the results listed in the CAP participant summary to verify accuracy. 6. During the survey on 05/18/2023 at 4:30 PM, the LD confirmed that there was no documentation of the laboratory's self-evaluation of ungraded CAP PT results for the 2023 CM-A and FH3-A PT events. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of performance verification records and email communication with the laboratory director (LD), the laboratory failed to provide documentation demonstrating comparable performance specifications to the manufacturer for the Sysmex CA-600 coagulation analyzer. Findings: 1. The laboratory used the Sysmex CA-600 coagulation analyzer to test for prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer. 2. Performance verification records contained instrument printouts, but did not include documentation that the laboratory's results were comparable to the manufacturer's performance specifications for accuracy, precision, reportable range, and reference intervals for PT, aPTT, fibrinogen, and D-dimer. 3. In an email received on 05/19/2023 at 3:11 PM, the LD confirmed that the original signed validation/verification documentation for the Sysmex CA-600 coagulation instrument could not be found. D5775 COMPARISON OF TEST RESULTS CFR(s): 493.1281(a)(c) (a) If a laboratory performs the same test using different methodologies or instruments, or performs the same test at multiple testing sites, the laboratory must have a system that twice a year evaluates and defines the relationship between test results using the different methodologies, instruments, or testing sites. (c) The laboratory must document all test result comparison activities. This STANDARD is not met as evidenced by: Based on record review, interview with the technical supervisor (TS), and email communication with the laboratory director (LD), the laboratory failed to perform a comparison of test results from two instruments used for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcription polymerase chain reaction (RT-PCR) testing at least twice a year. Findings: 1. The laboratory performed SARS-CoV-2 RT-PCR testing using a QuantStudio 7 Flex and a QuantStudio 12K Flex instrument. 2. During the survey on 05/18/2023 at 3:45 PM, the TS stated that a test results comparison from each instrument was last performed when the laboratory acquired the QuantStudio 7 Flex instrument. 3. In an email received on 05/19/2023 at 3:11 PM, the LD confirmed that the last instrument comparison was performed on 06 /23/2022. D6092 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iv) The laboratory director must ensure an approved

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 12, 2021

Survey Type: Standard

Survey Event ID: EOD611

Deficiency Tags: D5807 D5209

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on observation of records and interview with the technical supervisor, the laboratory did not perform competency evaluations for the clinical consultant. Findings: 1. The personnel file for the clinical consultant did not include competency check evaluations (performed by the laboratory director) to ensure that the clinical consultant performed duties as required and in a reliable manner; and 2. This was confirmed during interview, with the technical supervisor, on the afternoon of the day of survey. D5807 TEST REPORT CFR(s): 493.1291(d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. This STANDARD is not met as evidenced by: Based on review of one final test report for the reporting of a patient blood glucose result, the report did not include the reference range for the blood glucose result. Findings: 1. The glucose reference (normal) range was not reported on the one final report for Patient A who had a routine chemistry panel that included results for blood glucose. The reference ranges for all other chemistry analytes were given on the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- report; and 2. The missing reference range for the blood glucose was confirmed during interview with the technical supervisor during the afternoon of the day of survey. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access