Aesthetic Dermatology, Llc

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 31D2001790
Address 771 Route 70 E, Marlton, NJ, 08053
City Marlton
State NJ
Zip Code08053
Phone(856) 596-3393

Citation History (1 survey)

Survey - November 21, 2019

Survey Type: Standard

Survey Event ID: A37911

Deficiency Tags: D5217 D5401 D5787

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on the lack of a Biannual Assessment (BA) records and interview with the Office Manager (OM), the laboratory failed to verify the accuracy of Histopathology testing twice annually in the calendar years 2018 and 2019. The OM confirmed on 11 /21/19 at 11:50 am the laboratory did not perform BA twice annually. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual, the Microscope daily maintenance log, observation of the microscope and interview with the Office Manager (OM), the laboratory failed to follow Microscope Maintenance Procedure (MMP) in the calendar year 2019. The finding includes: 1. The PM stated to clean microscope at the end of each day of testing but there was no documentation of maintenance performed in the calendar year 2019. 2. The OM confirmed on 11/21/19 at 10:00 am that the laboratory did not follow MMP. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D5787 TEST RECORDS CFR(s): 493.1283(a) The laboratory must maintain an information or record system that includes the following: (a)(1) The positive identification of the specimen. (a)(2) The date and time of specimen receipt into the laboratory. (a)(3) The condition and disposition of specimens that do not meet the laboratory's criteria for specimen acceptability. (a)(4) The records and dates of all specimen testing, including the identity of the personnel who performed the test(s). This STANDARD is not met as evidenced by: Based on surveyor review of the Patient Manifest (PM) included with Histopathology slides, and interview with the Office Manager (OM), the laboratory failed to maintain an accurate information system for Histopathology slides from 11/28/17 to the date of the survey. The findings include: 1. Review of a PM received from a laboratory did not list the number of slides received for each patient. 2. The OM confirmed on 11/21 /19 at 11:25 am that the laboratory did not maintain an accurate information system. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access