Afc Urgent Care

CLIA Laboratory Citation Details

1
Total Citation
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 07D2115258
Address 4200 Main St, Bridgeport, CT, 06606
City Bridgeport
State CT
Zip Code06606
Phone(203) 916-5151

Citation History (1 survey)

Survey - March 9, 2018

Survey Type: Complaint

Survey Event ID: 0GQU11

Deficiency Tags: D2000 D5411 D5441 D6078 D5400 D5423 D6076

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Based on record review and staff interview the laboratory failed to enroll in proficiency testing (PT) for the specialty of chemistry. Findings include: 1. Record review of the laboratory's patient logs on 3/9/18 revealed 3 patients were tested using the Troponin I OneStep RapiCard Insta-test system, on 1/21/18 (44394) , 2/1/18 (77148) and 2/9/18 (90412). 2. During telephone interview on 3/28/18 with laboratory manager at 10:30 AM he/she confirmed the above findings. The LM further revealed the laboratory was not enrolled in PT for Troponin in 2016, 2017 and 2018 and thought the troponin I Rapid OneStep Insta test was a CLIA waived test. D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on record review and staff interview, the laboratory failed to follow the manufacturer's instructions for the Troponin I OneStep Rapid Insta test (refer to D5411); failed to established performance specifications for the not FDA approved Troponin I OneStep Rapid Insta prior to patient testing (refer to D5423); failed to establish control procedures to monitor the accuracy and precision of the tropinin I OneStep Rapid Insta test process (refer to D5441). D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to follow the manufacturer's instructions for the Troponin I OneStep Rapid Insta test in the specialty of chemistry. Findings include: 1. Record review of the laboratory's patient logs from 7/17/17 through 3/9/18 on 3/9/18 revealed 3 patients were tested for troponin, one on 1/21/18 (44394) one on 2/1/18 (77148) and on 2/9/18 (90412). 2. Record review of the package insert for the OneStep Troponin I RapiCard Serum/WB Insta Card on 3/9/18 revealed controls cTnI positive and cTnI negative are required but not provided. 3. During telephone interview on 3/28/18 with laboratory manager at 10:15 AM he/she confirmed quality controls were not performed on 1/21/18, 2/1/18 or 2/9/18 for the troponin test. D5423 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(2) Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (2)(i) Accuracy. (2)(ii) Precision. (2)(iii) Analytical sensitivity. (2)(iv) Analytical specificity to include interfering substances. (2)(v) Reportable range of test results for the test system. (2)(vi) Reference intervals (normal values). (2)(vii) Any other performance characteristic required for test performance. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to establish performance specifications for the OneStep Troponin I RapidCard Serum/WB Insta test prior to patient testing for high complexity testing in the specialty of chemistry. Findings include: 1. Record review of the laboratory's patient logs on 3/9/18 for the period of 7/17/17 through 3/9/18 revealed the laboratory performed patient testing on -- 2 of 4 -- 3 patients, one on 1/21/18 (44394), one on 2/1/18 (77148) and on 2/9/18 (90412) using the troponin I OneStep RapiCard Insta test system. 2. Record review of the manufacture package insert for the above test on 3/9/18 revealed that it was not CLIA waived nor FDA approved. 3. Review of the FDA website on 3/9/18 for the above test revealed the test system/manufacture was not listed in the FDA CLIA database. 4. During telephone interview on 3/28/18 with laboratory manager at 10:15 AM confirmed performance specifications were not established for the above troponin I test system and patient testing was performed on 1/21/18 (44394), 2/1/18 (77148) and 2/9/18 (90412). D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to establish control procedures that monitor the accuracy and precision of the Troponin I OneStep Rapid Insta test. Findings include: 1. Record review of the laboratory's patient logs on 3/9/18 for the period of 7/17/17 through 3/9/18 revealed the laboratory performed patient testing on 3 patients, one on 1/21/18 (44394), one on 2/1/18 (77148) and on 2/9/18 (90412) using the troponin I OneStep RapiCard Insta test system. 2. During telephone interview on 3/28/18 with laboratory manager at 10:15 AM confirmed the laboratory did not establish control procedures or perform QC for the troponin OneStep RapiCard test system. D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: Based on record review and staff interview, the laboratory director (LD) failed to qualify as LD for high complexity testing in the specialty of chemistry. Refer to D6078 D6078 LABORATORY DIRECTOR QUALIFICATIONS CFR(s): 493.1443 The laboratory director must be qualified to manage and direct the laboratory -- 3 of 4 -- personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must-- (b)(1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (b) (1)(ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology or possess qualifications that are equivalent to those required for such certification; or (b)(2) Be a doctor of medicine, a doctor of osteopathy or doctor of podiatric medicine licensed to practice medicine, osteopathy or podiatry in the State in which the laboratory is located; and (b)(2)(i) Have at least one year of laboratory training during medical residency (for example, physicians certified either in hematology or hematology and medical oncology by the American Board of Internal Medicine); or (b)(2)(ii) Have at least 2 years of experience directing or supervising high complexity testing; or (b)(3) Hold an earned doctoral degree in a chemical, physical, biological or clinical laboratory science from an accredited institution and-- (b)(3)(i) Be certified and continue to be certified by a board approved by HHS; or (b)(3)(ii) Before February 24, 2003, must have served or be serving as director of a laboratory performing high complexity testing and must have at least-- (b)(3)(ii)(A) Two years of laboratory training or experience, or both; and (b)(3)(ii)(B) Two years of laboratory experience directing or supervising high complexity testing. (b)(4) Be serving as a laboratory director and must have previously qualified or could have qualified as a laboratory director under regulations at 42 CFR 493.1415, published March 14, 1990 at 55 FR 9538, on or before February 28, 1992; or (b)(5) On or before February 28, 1992, be qualified under State law to direct a laboratory in the State in which the laboratory is located; or (b)(6) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, the American Osteopathic Board of Pathology, or possess qualifications that are equivalent to those required for certification. This STANDARD is not met as evidenced by: Based on record review and staff interview, laboratory director (LD) failed to meet LD requirements to operate and perform high complexity testing. Findings include: 1. Record review of the laboratory director's (LD) qualifications on 3/9/18 revealed the LD failed to have at least 2 years of experience directing or supervising high complexity testing. 2. During telephone interview LD on 3/21/18 at 1:00 PM confirmed the OneStep Troponin I RapiCard Serum/WB Insta test system was used for the above dates. LD also stated he/she thougth the test was CLIA waived. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access