Ak Diagnostic Laboratory Llc

CLIA Laboratory Citation Details

3
Total Citations
134
Total Deficiencyies
61
Unique D-Tags
CMS Certification Number 23D2242011
Address 35540 W Michigan Avenue, Wayne, MI, 48184
City Wayne
State MI
Zip Code48184

Citation History (3 surveys)

Survey - February 18, 2025

Survey Type: Standard

Survey Event ID: OYB211

Deficiency Tags: D3000 D3001 D3007 D5022 D5311 D5407 D5413 D5415 D5417 D5423 D5427 D5437 D5469 D5783 D6076 D6079 D6083 D6084 D6085 D6087 D6093 D6087 D6102 D6106 D6108 D6109 D6141 D6143 D6150 D6143 D6171 D6177 D6178 D6179 D0000 D0000 D3000 D3001 D3007 D5022 D5311 D5407 D5413 D5415 D5417 D5423 D5427 D5437 D5469 D5783 D6076 D6079 D6083 D6084 D6085 D6096 D6093 D6096 D6102 D6106 D6108 D6109 D6141 D6168 D6150 D6168 D6171 D6177 D6178 D6179

Summary:

Summary Statement of Deficiencies D0000 An initial certification survey was performed on February 18, 2025 at AK Diagnostic Laboratory LLC by the State of Michigan Licensing and Regulatory Affairs Department. During the survey, ti was determined Immediate Jeopardy (IJ) existed for the following condition-level deficiencies: 493.1100 Condition: Facility administration. 493.1213 Condition: Toxicology. 493.1441 Condition: Laboratories performing high complexity testing; laboratory director. 493.1447 Condition: Laboratories performing high complexity testing; technical supervisor. 493.1459 Condition: Laboratories performing high complexity testing; general supervisor. 493. 1487 Condition: Laboratories performing high complexity testing; testing personnel. D3000 FACILITY ADMINISTRATION CFR(s): 493.1100 Each laboratory that performs nonwaived testing must meet the applicable requirements under 493.1101 through 493.1105, unless HHS approves a procedure that provides equivalent quality testing as specified in Appendix C of the State Operations Manual (CMS Pub. 7). This CONDITION is not met as evidenced by: . Based on observations, record review, and interviews, the laboratory failed to have a sink in the laboratory space to wash hands and clean glassware (refer to D3001) and failed to have sufficient reagents to perform its to perform its liquid chromatography- mass spectrometry (LCMS) urine toxicology testing (refer to D3007). D3001 FACILITIES CFR(s): 493.1101(a)(1) (a) The laboratory must be constructed, arranged, and maintained to ensure the following: (a)(1) The space, ventilation, and utilities necessary for conducting all phases of the testing process. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 16 -- This STANDARD is not met as evidenced by: . Based on observation, record review, and interview with office personnel, the laboratory failed to have a sink in the laboratory space to wash hands and clean glassware for one (January 2025 to February 2025) of one month since the laboratory started testing. Findings include: 1. The surveyor observed the laboratory on 2/18/25 at 10:25 am and noticed there was no sink anywhere in the laboratory suite. There were reusable glass containers with reagents on two of the Schimadzu toxicology analyzers, glass volumetric flasks, and a glass graduated cylinder. 2. A review of the laboratory's "Mix Diluent Procedure" revealed the laboratory uses glass volumetric flasks and amber glass screw-capped vials routinely in making reagents. 3. An interview on 2/18/25 at 10:25 am with the office personnel confirmed the laboratory does not have a sink. D3007 FACILITIES CFR(s): 493.1101(b) (b) The laboratory must have appropriate and sufficient equipment, instruments, reagents, materials, and supplies for the type and volume of testing it performs. This STANDARD is not met as evidenced by: . Based on observation, record review, and interview with office personnel, the laboratory failed to have sufficient reagents to perform its liquid chromatography- mass spectrometry (LCMS) urine toxicology testing when observed on 2/18/25. Findings include: 1. A review of the laboratory's "Reagents and Chemicals" policy revealed a list of reagents. The list included "Isopropanol (LC/MS)" and included the statement "All the solvents should be LCMS grade products." 2. The surveyor observed the laboratory's reagent storage on 2/18/25 at 10:43 am. There was a lack of LCMS-grade isopropanol. The only isopropanol present was a bottle of "70% Isopropyl Alcohol" listing its uses as "First Aid Antiseptic" and "For Rubbing & Massaging." 3. A review of the laboratory's "Standards" procedure revealed a section stating, "Reference standards and the corresponding surrogate internal standards (SIS) obtained from Cerilliant (Round Rock, TX). Should store -18 to -24 degrees C in screw capped amber glass vials labeled with analyte name, concentration, and date of opened." 4. The surveyor observed the laboratory's freezer on 2/18/25 at 10:54 am revealed a lack of standards used to make the laboratory's calibration and control materials. 5. An interview on 2/18/25 at 2:31 pm with the office personnel confirmed the lack of isopropanol and standards present in the laboratory. D5022 TOXICOLOGY CFR(s): 493.1213 If the laboratory provides services in the subspecialty of Toxicology, the laboratory must meet the requirements specified in 493.1230 through 493.1256, and 493.1281 through 493.1299. This CONDITION is not met as evidenced by: . Based on observations, record review, and interviews, the laboratory failed to establish policies and procedures to include urine specimen collection and transportation conditions (refer to D5311), failed to date approved procedures before -- 2 of 16 -- use (refer to D5407), failed to ensure the room temperature conditions were within the laboratory's criteria for proper storage (refer to D5413), failed to label its controls and calibrators with the preparation and expiration dates (refer to D5415), failed to ensure reagents used in urine toxicology testing had not exceeded expiration dates (refer to D5417), failed to establish performance specifications of its Schimadzu liquid chromatography mass spectrometry (LCMS) urine toxicology test system to include analytical sensitivity prior to testing patients (refer to D5423 A), failed to establish performance specifications of its Schimadzu liquid chromatography mass spectrometry (LCMS) urine toxicology test system to include specimen storage and stability prior to testing patients (refer to D5423 B), failed to have documentation of the instrumentation measurements used in the laboratory's establishment of performance specifications of its Schimadzu liquid chromatography mass spectrometry (LCMS) urine toxicology test system (refer to D5427 A), failed to have the reference laboratory test reports used to establish accuracy performance specifications of its Schimadzu liquid chromatography mass spectrometry (LCMS) urine toxicology test system (refer to D5427 B), failed to perform and document calibrations for its urine toxicology testing (refer to D5437), failed to establish criteria and statistical parameters for each batch of control materials prior to use in urine toxicology testing (refer to D5469), and failed to perform

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 15, 2023

Survey Type: Standard

Survey Event ID: 4BJY12

Deficiency Tags: D0000 D6076 D6078 D6087 D6101 D6135 D6136 D6168 D6175 D0000 D6076 D6078 D6087 D6101 D6135 D6136 D6168 D6175

Summary:

Summary Statement of Deficiencies D0000 . The purpose of this unannounced survey was for a follow-up to the 5/15/23 initial survey. The Department of Licensing and Regulatory Affairs has evaluated this facility and determined that it is not in compliance with CLIA regulations (42 CFR Part 93, effective April 24, 2003). D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: . Based on record review and interviews, the Laboratory Director was not qualified to manage and direct performance of high complexity testing (refer to D6078), failed to ensure laboratory personnel followed procedures for specimen rejection for 18 of 18 female specimens reviewed for Prostate Specific Antigen (PSA) testing (refer to D6087 A), failed to ensure laboratory personnel followed its Prostate Specific Antigen (PSA) test procedure for 18 of 18 female specimens with Prostate Specific Antigen (PSA) testing reviewed (refer to D6087 B), failed to ensure the Clinical Consultant provided consultation regarding the appropriateness of ordering Prostate Specific Antigen (PSA) testing on female patient specimens (refer to D6101 A), and failed to ensure testing personnel followed the laboratory's Prostate Specific Antigen (PSA) test procedure for 18 of 18 female specimens with Prostate Specific Antigen (PSA) testing (refer to D6101 B). D6078 LABORATORY DIRECTOR QUALIFICATIONS CFR(s): 493.1443 The laboratory director must be qualified to manage and direct the laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must-- (b)(1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (b) (1)(ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology or possess qualifications that are equivalent to those required for such certification; or (b)(2) Be a doctor of medicine, a doctor of osteopathy or doctor of podiatric medicine licensed to practice medicine, osteopathy or podiatry in the State in which the laboratory is located; and (b)(2)(i) Have at least one year of laboratory training during medical residency (for example, physicians certified either in hematology or hematology and medical oncology by the American Board of Internal Medicine); or (b)(2)(ii) Have at least 2 years of experience directing or supervising high complexity testing; or (b)(3) Hold an earned doctoral degree in a chemical, physical, biological or clinical laboratory science from an accredited institution and-- (b)(3)(i) Be certified and continue to be certified by a board approved by HHS; or (b)(3)(ii) Before February 24, 2003, must have served or be serving as director of a laboratory performing high complexity testing and must have at least-- (b)(3)(ii)(A) Two years of laboratory training or experience, or both; and (b)(3)(ii)(B) Two years of laboratory experience directing or supervising high complexity testing. (b)(4) Be serving as a laboratory director and must have previously qualified or could have qualified as a laboratory director under regulations at 42 CFR 493.1415, published March 14, 1990 at 55 FR 9538, on or before February 28, 1992; or (b)(5) On or before February 28, 1992, be qualified under State law to direct a laboratory in the State in which the laboratory is located; or (b)(6) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, the American Osteopathic Board of Pathology, or possess qualifications that are equivalent to those required for certification. This STANDARD is not met as evidenced by: . Based on record review and interview with the Technical Consultant, the Laboratory Director was not qualified to manage and direct performance of high complexity testing from 8/1/23 to 8/15/23. Findings include: 1. A review of the laboratory's patient test requests and test reports from 7/28/23 to 8/14/23 revealed the following 18 patients were indicated as female on the test request and had PSA testing reported: a. Patient 56855 had PSA testing and results reported on 8/1/23. b. Patient 56856 had PSA testing and results reported on 8/1/23. c. Patient 56905 had PSA testing and results reported on 8/3/23. d. Patient 56956 had PSA testing and results reported on 8/3 /23. e. Patient 56959 had PSA testing and results reported on 8/3/23. f. Patient 57101 had PSA testing and results reported on 8/14/23. g. Patient 57143 had PSA testing and results reported on 8/14/23. h. Patient 57102 had PSA testing and results reported on 8 /14/23. i. Patient 57141 had PSA testing and results reported on 8/14/23. j. Patient 57144 had PSA testing and results reported on 8/14/23. k. Patient 57145 had PSA testing and results reported on 8/14/23. l. Patient 57200 had PSA testing and results reported on 8/14/23. m. Patient 57201 had PSA testing and results reported on 8/14 /23. n. Patient 57203 had PSA testing and results reported on 8/14/23. o. Patient 57205 had PSA testing and results reported on 8/14/23. p. Patient 57222 had PSA testing and results reported on 8/14/23. q. Patient 57221 had PSA testing and results reported on 8/14/23. r. Patient 57254 had PSA testing and results reported on 8/14/23. 2. A review of the laboratory's "Hybritech Prostate Specific Antigen (PSA) Test -- 2 of 5 -- Procedure" approved by the Laboratory Director on 6/30/23 revealed a section titled "Intended Use" stating, "This device is indicated for the measurement of serum PSA in conjunction with digital rectal examination (DRE) as an aid in the detection of prostate cancer in men aged 50 years or older. Prostate biopsy is required for the diagnosis of cancer. This device is further indicated for the serial measurement of PSA to aid in the prognosis and management of patients with prostate cancer" and revealed no indication of this assay to be used on patients indicated as female. This test system defaulted to high complexity testing. 3. A review of the Laboratory Director's qualifications revealed a lack of documentation showing the high complexity Laboratory Director qualification requirements were met. 4. An interview on 8/15/23 at 10:48 am with Technical Consultant confirmed the laboratory had performed PSA testing on female patient specimens against laboratory procedure and testing would be considered high complexity, making the Laboratory Director unqualified to serve. D6087 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(3)(iii) The laboratory director must ensure that laboratory personnel are performing the test methods as required for accurate and reliable results. This STANDARD is not met as evidenced by: . A. Based on record review and interview, the Laboratory Director failed to ensure laboratory personnel followed procedures for specimen rejection for 18 of 18 female specimens reviewed for Prostate Specific Antigen (PSA) testing. Refer to D5311. B. Based on record review and interview, the Laboratory Director failed to ensure laboratory personnel followed its Prostate Specific Antigen (PSA) test procedure for 18 of 18 female specimens with Prostate Specific Antigen (PSA) testing reviewed. Refer to D5401. D6101 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(11) The laboratory director must employ a sufficient number of laboratory personnel with the appropriate education and either experience or training to provide appropriate consultation, properly supervise and accurately perform tests and report test results in accordance with the personnel responsibilities described in this subpart. This STANDARD is not met as evidenced by: . A. Based on record review and interview, the Laboratory Director failed to ensure the Clinical Consultant provided consultation regarding the appropriateness of ordering Prostate Specific Antigen (PSA) testing on female patient specimens. Refer to D6136. B. Based on record review and interview, the Laboratory Director failed to ensure testing personnel followed the laboratory's Prostate Specific Antigen (PSA) test procedure for 18 female specimens with Prostate Specific Antigen (PSA) testing. Refer to D6175. D6135 CLINICAL CONSULTANT QUALIFICATIONS CFR(s): 493.1455 The clinical consultant must be qualified to consult with and render opinions to the -- 3 of 5 -- laboratory's clients concerning the diagnosis, treatment and management of patient care. The clinical consultant must-- (a) Be qualified as a laboratory director under 493. 1443(b)(1), (2), or (3)(i) or, for the subspecialty of oral pathology, 493.1443(b)(6); or (b) Be a doctor of medicine, doctor of osteopathy, doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located. This STANDARD is not met as evidenced by: . Based on record review and interview, the Clinical Consultant failed to provide consultation regarding the appropriateness of ordering Prostate Specific Antigen (PSA) testing on female patient specimens. Refer to D6136. D6136 CLINICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1457 The clinical consultant provides consultation regarding the appropriateness of the testing ordered and interpretation of test results. This STANDARD is not met as evidenced by: . Based on record review and interview with the Technical Consultant, the Clinical Consultant failed to provide consultation regarding the appropriateness of ordering Prostate Specific Antigen (PSA) testing on female patient specimens for 1 of 1 client the laboratory serves. Findings include: 1. A review of the laboratory's test requests revealed 18 female patients had PSA testing ordered between 7/28/23 to 8/11/23 from the laboratory's one client: a. Patient 56855 had PSA testing ordered on 7/28/23 and results reported on 8/1/23. b. Patient 56856 had PSA testing ordered on 7/28/23 and results reported on 8/1/23. c. Patient 56905 had PSA testing ordered on 7/31/23 and results reported on 8/3/23. d. Patient 56956 had PSA testing ordered on 8/1/23 and results reported on 8/3/23. e. Patient 56959 had PSA testing ordered on 8/1/23 and results reported on 8/3/23. f. Patient 57101 had PSA testing ordered on 8/7/23 and results reported on 8/14/23. g. Patient 57143 had PSA testing ordered on 8/7/23 and results reported on 8/14/23. h. Patient 57102 had PSA testing ordered on 8/7/23 and results reported on 8/14/23. i. Patient 57141 had PSA testing ordered on 8/8/23 and results reported on 8/14/23. j. Patient 57144 had PSA testing ordered on 8/8/23 and results reported on 8/14/23. k. Patient 57145 had PSA testing ordered on 8/8/23 and results reported on 8/14/23. l. Patient 57200 had PSA testing ordered on 8/9/23 and results reported on 8/14/23. m. Patient 57201 had PSA testing ordered on 8/9/23 and results reported on 8/14/23. n. Patient 57203 had PSA testing ordered on 8/9/23 and results reported on 8/14/23. o. Patient 57205 had PSA testing ordered on 8/9/23 and results reported on 8/14/23. p. Patient 57222 had PSA testing ordered on 8/11/23 and results reported on 8/14/23. q. Patient 57221 had PSA testing ordered on 8/11/23 and results reported on 8/14/23. r. Patient 57254 had PSA testing ordered on 8/11/23 and results reported on 8/14/23. 2. An interview on 8/16/23 at 8:58 am with the Technical Consultant confirmed there was a lack of documentation of consultation with the Clinical Consultant regarding the appropriateness of PSA testing in female patients for the client requesting testing. D6168 TESTING PERSONNEL CFR(s): 493.1487 The laboratory has a sufficient number of individuals who meet the qualification -- 4 of 5 -- requirements of 493.1489 of this subpart to perform the functions specified in 493. 1495 of this subpart for the volume and complexity of testing performed. This CONDITION is not met as evidenced by: . Based on record review and interview, testing personnel failed to follow its Prostate Specific Antigen (PSA) test procedure for 18 of 18 female specimens with Prostate Specific Antigen (PSA) testing. Refer to D6175. D6175 TESTING PERSONNEL RESPONSIBILITIES CFR(s): 493.1495(b)(1) Each individual performing high complexity testing must follow the laboratory's procedures for specimen handling and processing, test analyses, reporting and maintaining records of patient test results. This STANDARD is not met as evidenced by: . Based on record review and interview, testing personnel failed to follow its Prostate Specific Antigen (PSA) test procedure for 18 of 18 female specimens with Prostate Specific Antigen (PSA) testing. Refer to D5401. -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 15, 2023

Survey Type: Standard

Survey Event ID: 4BJY11

Deficiency Tags: D2000 D3011 D2000 D3011 D5016 D5020 D5305 D5309 D5311 D5313 D5401 D5415 D5439 D5801 D6000 D6011 D6013 D6015 D6026 D6028 D6031 D6033 D6035 D6056 D6057 D5016 D5020 D5305 D5309 D5311 D5313 D5401 D5415 D5439 D5801 D6000 D6011 D6013 D6015 D6026 D6028 D6031 D6033 D6035 D6056 D6057

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to enroll in an approved proficiency testing program for its regulated analytes for 15 (5/1/23 to 5/15/23) of 15 days since the laboratory had started testing 5/1/23. Findings include: 1. An interview with the Laboratory Director on 5/15/23 at 10:00 am revealed the laboratory started testing on 5/1/23. 2. A review of the laboratory's test menu revealed the following regulated analytes: a. Alanine Aminotransferase (ALT) b. Albumin c. Alkaline Phosphatase d. Aspartate Aminotransferase (AST) e. Bilirubin, total f. Calcium, total g. Chloride h. Cholesterol, total i. Cholesterol, HDL j. Creatinine k. Glucose l. Potassium m. Sodium n. Total Protein o. Triglycerides p. Blood Urea Nitrogen (BUN) q. Thyroid Stimulating Hormone 3. A review of email correspondence provided by the laboratory with a proficiency testing program revealed a lack of enrollment. 4. The surveyor requested documentation showing enrollment in a proficiency testing program on 5/15/23 at 10:25 am and it was not made available. 5. An interview on 5/15/23 at 1:32 pm with the Laboratory Director confirmed documentation showing the laboratory had enrolled in an approved proficiency testing program was not available. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 11 -- D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: . Based on observation, record review, and interview with the Laboratory Director, the laboratory failed to observe its established safety procedures for 15 (5/1/23 to 5/15/23) of 15 days since the laboratory had started testing 5/1/23. Findings include: 1. The surveyor observed an eye wash squeeze bottle in the breakroom down the hall from the laboratory that contained clear fluid and no indication of an expiration date. 2. An interview on 5/15/23 at 10:37 am with the Laboratory Director revealed the bottle was filled with tap water about a week ago and had been sitting at room temperature in the breakroom area since it was filled. 3. A review of the laboratory's Eyewash Procedure and Log" revealed a section stating, "Bacterial and parasitic organisms are ubiquitous in tap water. In most instances, the number of organisms will not be significant, but they proliferate in stagnant, residual water and then become dangerous" and "In general, squeeze bottles should not be used, except where the hazard severity, or distance from plumbed eyewash equipment requires personal equipment at workstations for immediate flushing at aplumbed or self-contained unit" and "For emergency eyewash stations to be effective. The affected eye(s) must be flushed immediately and thoroughly for at least 15 minutes using a large supply of clean fluid under low pressure." 4. A review of the laboratory's "Electrical and Mechanical Safety Plan" revealed a section titled "Emergency Equipment: Eye Wash" stating, "Any employee coming in contact with any hazardous material will be oriented to the actual chemicals and emergency equipment in use in the laboratory. Training for Emergency Equipment: a. This is the responsibility of the Supervisor. b. The training is to be documented on the Employee Training Log. c. The original training record goes to the staff file. A copy may be given to the employee. "Eye Wash stations are verified weekly for operation by checking that: i. The devices stay on without using hands ii. Eye wash nozzles are covered. Caps are intact and clean iii. The height of the stream of water is to be 3-6 inches to assure correct pressure. iv. Water temperatures are to be tepid. v. Access is within 10 seconds from hazard, and not obstructed. vi. Document the actions on the eye wash testing log." 5. An interview on 5/15/23 at 1:32 pm with the Laboratory Director confirmed the laboratory had not followed its established safety policies regarding the eye wash station. D5016 ROUTINE CHEMISTRY CFR(s): 493.1210 If the laboratory provides services in the subspecialty of Routine Chemistry, the laboratory must meet the requirements specified in 493.1230 through 493.1256, 493. 1267, and 493.1281 through 493.1299. This CONDITION is not met as evidenced by: . Based on observations, record review, and interviews, the laboratory failed to ensure test requests included the date and time of specimen collection (Refer to D5305), failed to establish written policies and procedures for specimen storage, preservation, conditions for specimen transportation, and specimen referral (Refer to D5311), failed -- 2 of 11 -- to establish test procedures for its chemistry testing (Refer to D5401), failed to label its control materials with the expiration dates reflecting their stability once reconstituted (Refer to D5415), and failed to establish criteria to verify the calibration verification performed on the Horiba Pentra 400 chemistry analyzer (Refer to D5439). D5020 ENDOCRINOLOGY CFR(s): 493.1212 If the laboratory provides services in the subspecialty of Endocrinology, the laboratory must meet the requirements specified in 493.1230 through 493.1256, and 493.1281 through 493.1299. This CONDITION is not met as evidenced by: . Based on observations, record review, and interviews, the laboratory failed to ensure test requests included the date and time of specimen collection (D5305), failed to establish written policies and procedures for specimen storage, preservation, conditions for specimen transportation, and specimen referral (Refer to D5311), failed to establish test procedures for its endocrinology testing (Refer to D5401), failed to label its control materials with the expiration dates reflecting their stability once reconstituted (Refer to D5415), and failed to ensure test reports for its patient testing completed using the Beckman Coulter Access 2 immunoassay analyzer were issued to the ordering provider (Refer to D5801). D5305 TEST REQUEST CFR(s): 493.1241(c) The laboratory must ensure the test requisition solicits the following information: (1) The name and address or other suitable identifiers of the authorized person requesting the test and, if appropriate, the individual responsible for using the test results, or the name and address of the laboratory submitting the specimen, including, as applicable, a contact person to enable the reporting of imminently life threatening laboratory results or panic or alert values. (2) The patient's name or unique patient identifier. (3) The sex and age or date of birth of the patient. (4) The test(s) to be performed. (5) The source of the specimen, when appropriate. (6) The date and, if appropriate, time of specimen collection. (7) For Pap smears, the patient's last menstrual period, and indication of whether the patient had a previous abnormal report, treatment, or biopsy. (8) Any additional information relevant and necessary for a specific test to ensure accurate and timely testing and reporting of results, including interpretation, if applicable. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to ensure test requests included the date and time of specimen collection for 7 (Patients 54926, 54970, 54971, 55009, 55019, 55059, and 55010) of 7 patient test records reviewed. Findings include: 1. An interview on 5/15/23 at 11:55 am with the Laboratory Director revealed the laboratory has one client and it is a home health agency that collects specimens within the patients' homes. 2. A review of patient test requisitions revealed the following patients tested on 5/10/23 and 5/12/23 had not had the date and time of specimen collection indicated: a. Patient 54926 b. Patient 54970 c. Patient 54971 d. Patient 55009 e. Patient 55019 f. Patient 55059 g. Patient 55010 3. An interview on 5/15/23 at 12:40 pm with the Laboratory Director confirmed the -- 3 of 11 -- laboratory had not ensured the time and date of collection had been indicated on the test requests for the patients listed above. D5309 TEST REQUEST CFR(s): 493.1241(e) If the laboratory transcribes or enters test requisition or authorization information into a record system or a laboratory information system, the laboratory must ensure the information is transcribed or entered accurately. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to ensure test requests transcribed included a request for direct low-density lipoprotein (LDL) testing for 6 (Patients 54926, 54970, 54971, 55009, 55059, and 55010) of 6 patients with an order for testing. Findings include: 1. A review of the 6 patient test records revealed the following patients had direct LDL testing listed on the test request: a. Patient 54926 b. Patient 54970 c. Patient 54971 d. Patient 55009 e. Patient 55059 f. Patient 55010 2. A review of the laboratory's patient test reports listed above revealed a lack of direct LDL results. 3. An interview on 5/15/23 at 1:32 pm with the Laboratory Director confirmed the laboratory had not accurately transcribed test requests to its reference laboratory to include all testing ordered. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to establish written policies and procedures for specimen storage, preservation, conditions for 15 (5/1/23 to 5/15/23) of 15 days since the laboratory had started testing 5/1/23. Findings include: 1. An interview on 5/15/23 at 11:55 am with the Laboratory Director revealed the laboratory has one client and it is a home health agency that collects specimens within the patients' homes. 2. A review of the laboratory's procedure manual revealed a lack of established written policies and procedures for specimen storage, preservation, conditions for specimen transportation, and specimen referral. 3. An interview on 5/15/23 at 11:28 am with the Laboratory Director confirmed the laboratory had not established written policies and procedures for specimen storage, preservation, conditions for specimen transportation, and specimen referral. D5313 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(b) The laboratory must document the date and time it receives a specimen. -- 4 of 11 -- This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to document the time it received specimens for 7 (Patients 54926, 54970, 54971, 55009, 55019, 55059, and 55010) of 7 patient test records reviewed. Findings include: 1. An interview on 5/15/23 at 11:55 am with the Laboratory Director revealed the laboratory has one client and it is a home health agency that collects specimens within the patients' homes and delivers the specimens to the laboratory. 2. A review of 7 patient test records revealed the laboratory failed to document the time the laboratory received specimens for the following patients tested on 5/10/23 and 5/12 /23: a. Patient 54926 b. Patient 54970 c. Patient 54971 d. Patient 55009 e. Patient 55019 f. Patient 55059 g. Patient 55010 3. An interview on 5/15/23 at 1:32 pm with the Laboratory Director confirmed the laboratory had not documented the time it received specimens. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to establish test procedures for its chemistry and endocrinology testing for 15 (5 /1/23 to 5/15/23) of 15 days since the laboratory had started testing 5/1/23. Findings include: 1. A review of the laboratory's policies and procedures revealed a lack of test procedures for chemistry and endocrinology testing using their Horiba Pentra 400 and Beckman Coulter Access 2 analyzers. 2. An interview on 5/15/23 at 11:43 am with the Laboratory Director confirmed the laboratory had not established test procedures for its chemistry and endocrinology testing. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to label its control materials with the expiration dates reflecting their stability once reconstituted for 4 (Bo-Rad Lyphochek Immunoassay Plus Levels 1 and 3 and ABX Pentra Multicontrol Levels 1 and 2.) of 4 control materials observed. Findings include: 1. The surveyor observed two sets of reconstituted control materials used in chemistry and endocrinology testing in the laboratory's refrigerator during a tour on 5 /15/23 at 10:15 am with the following information: a. ABX Pentra Multcontrol level 1 and 2 with 5/12/23 listed as the date of reconstitution. b. Lyphochek Immunoassay -- 5 of 11 -- Plus level 1 and 3 with 5/12/23 listed as the date of reconstitution. 2. An interview with the Laboratory Director on 5/15/23 at 10:15 am revealed the controls that had been reconstituted were stable 30 days. 3. A review of the laboratory's "ABX Pentra N MultiControl" manufacturer's instructions revealed a section stating, a. "Stability after reconstitution: i. 12 hours at 15 - 25C ii. 5 days at 2 - 8C iii. 28 days at (-15) - (-25)C b. Stability of total bilirubin and direct bilirubin after reconstitution: i. 8 hours at 15 - 25C ii. 24 hours at 2 - 8C iii. 14 days at (-15) - (-25)C c. Stability of ALT after reconstitution: i. 12 hours at 15 - 25C ii. 5 days at 2 - 8C iii. 14 days at (-15) - (-25)C" 4. A review of the laboratory's "Bio-Rad Lyphochek Immunoassay Plus Control Levels 1, 2 and 3" manufacturer's instructions revealed a section titled "Reconstituted and Refrigerated" stating, "After reconstituting and storing tightly capped at 2 to 8 degrees C, this product will be stable as follows: a. All analytes: 7 days b. Except: Folate and PSA (Total): 3 days at 2 to 8 degrees C." 5. An interview on 5/15/23 at 1: 32 pm with the Laboratory Director confirmed the controls listed above had not been labeled with the expiration date reflecting their reconstituted stability. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to establish criteria to assess the acceptability of calibration verification performed on the Horiba Pentra 400 chemistry analyzer for 1 (5/10/23) of 1 calibration verification event performed since the laboratory started testing. Findings include: 1. A review of the laboratory's calibration verification documentation performed on 5/10/23 revealed the raw data from 5 samples. 2. The surveyor requested the laboratory's calibration verification acceptability criteria and the standard values from the linearity standard samples on 5/15/23 at 12:13 pm and it was not made available. 3. An interview on 5/15/23 at 12:13 pm with the Laboratory Director revealed the laboratory had not established acceptability criteria and had not assessed the data from the 5 calibration verification samples that had been tested on 5 /10/23. -- 6 of 11 -- D5801 TEST REPORT CFR(s): 493.1291(a) The laboratory must have an adequate manual or electronic system(s) in place to ensure test results and other patient-specific data are accurately and reliably sent from the point of data entry (whether interfaced or entered manually) to final report destination, in a timely manner. This includes the following: (a)(1) Results reported from calculated data. (a)(2) Results and patient-specific data electronically reported to network or interfaced systems. (a)(3) Manually transcribed or electronically transmitted results and patient-specific information reported directly or upon receipt from outside referral laboratories, satellite or point-of-care testing locations. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to ensure test reports for its patient testing completed using the Beckman Coulter Access 2 immunoassay analyzer were issued to the ordering provider for 24 of 24 patients performed since testing began. Findings include: 1. A review of patient test records revealed a lack of patient test reports for the 24 patients receiving vitamin D, total PSA, and Thyroid Stimulating Hormone (TSH) testing using the Beckman Coulter Access 2 analyzer. 2. An interview on 5/15/23 at 1:32 pm with the Laboratory Director revealed the laboratory had not provided the ordering provider test reports for its testing completed using the Beckman Coulter Access 2 analyzer. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: . Based on record review, observation, and interviews, the Laboratory Director failed to ensure established safety procedures for its eye wash station were observed (Refer D6011), failed to ensure criteria to assess the acceptability of calibration verification performed on the Horiba Pentra 400 chemistry analyzer was established (Refer to D6013), failed to ensure enrollment in an approved proficiency testing program for its regulated analytes (Refer to D6015), failed to ensure test reports for its patient testing completed using the Beckman Coulter Access 2 immunoassay analyzer were issued to the ordering provider (Refer to D6026), failed to ensure the Technical Consultant had met the qualification requirements at 493.1411 (Refer to D6028 A), and failed to employ a qualified clinical consultant (Refer to D6028 B). D6011 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(2) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(2) and provide a safe environment in which employees are protected from physical, chemical, and biological hazards. -- 7 of 11 -- This STANDARD is not met as evidenced by: . Based on observation, record review and interview with the Laboratory Director, the Laboratory Director failed to ensure established safety procedures for its eye wash station were observed. Refer to D3011. D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the Laboratory Director failed to ensure criteria to assess the acceptability of calibration verification performed on the Horiba Pentra 400 chemistry analyzer was established. Refer to D5439. D6015 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4) Ensure that the laboratory is enrolled in an HHS approved proficiency testing program for the testing performed. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the Laboratory Director failed to ensure enrollment in an approved proficiency testing program for its regulated analytes. Refer to D2000. D6026 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(8) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(8) Ensure that reports of test results include pertinent information required for interpretation. This STANDARD is not met as evidenced by: -- 8 of 11 -- . Based on record review and interview with the Laboratory Director, the Laboratory Director failed to ensure test reports for its patient testing completed using the Beckman Coulter Access 2 immunoassay analyzer were issued to the ordering provider. Refer to D5801. D6028 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(10) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(10) Employ a sufficient number of laboratory personnel with the appropriate education and either experience or training to provide appropriate consultation, properly supervise and accurately perform tests and report test results in accordance with the personnel responsibilities described in this subpart; This STANDARD is not met as evidenced by: . A. Based on record review and interview with the Laboratory Director, the Laboratory Director failed to ensure the Technical Consultant had met the qualification requirements at 493.1411. Refer to D6035. B. Based on record review and interview with the Laboratory Director, the Laboratory Director failed to employ a qualified clinical consultant. Refer to D6057. D6031 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(13) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(13) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; This STANDARD is not met as evidenced by: . A. Based on record review and interview with the Laboratory Director, The Laboratory Director failed to ensure written policies and procedures for specimen storage, preservation, conditions for specimen transportation, and specimen referral were established and approved. Refer to D5311. B. Based on record review and interview with the Laboratory Director, the Laboratory Director failed to ensure written test procedures for its chemistry and endocrinology testing were established and approved. Refer to D5401. D6033 TECHNICAL CONSULTANT-MODERATE COMPEXITY CFR(s): 493.1409 The laboratory must have a technical consultant who meets the qualification requirements of 493.1411 of this subpart and provides technical oversight in accordance with 493.1413 of this subpart. -- 9 of 11 -- This CONDITION is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to ensure Technical Consultant had met the qualification requirements at 493.1411. Refer to D6035. D6035 TECHNICAL CONSULTANT QUALIFICATIONS CFR(s): 493.1411 (a) The technical consultant must be qualified and must possess a current license issued by the State in which the laboratory is located, if such licensing is required. (b) The technical consultant must-- (b)(1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (b)(1)(ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology or possess qualifications that are equivalent to those required for such certification; or (b)(2)(i) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (b)(2)(ii) Have at least one year of laboratory training or experience, or both in non-waived testing, in the designated specialty or subspecialty areas of service for which the technical consultant is responsible (for example, physicians certified either in hematology or hematology and medical oncology by the American Board of Internal Medicine are qualified to serve as the technical consultant in hematology); or (b)(3)(i) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory science or medical technology from an accredited institution; and (b)(3)(ii) Have at least one year of laboratory training or experience, or both in non-waived testing, in the designated specialty or subspecialty areas of service for which the technical consultant is responsible; or (b)(4)(i) Have earned a bachelor's degree in a chemical, physical or biological science or medical technology from an accredited institution; and (b)(4)(ii) Have at least 2 years of laboratory training or experience, or both in non-waived testing, in the designated specialty or subspecialty areas of service for which the technical consultant is responsible. Note: The technical consultant requirements for "laboratory training or experience, or both" in each specialty or subspecialty may be acquired concurrently in more than one of the specialties or subspecialties of service, excluding waived tests. For example, an individual who has a bachelor's degree in biology and additionally has documentation of 2 years of work experience performing tests of moderate complexity in all specialties and subspecialties of service, would be qualified as a technical consultant in a laboratory performing moderate complexity testing in all specialties and subspecialties of service. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to ensure Technical Consultant had met the qualification requirements at 493.1411 for 1 of 1 Technical Consultant listed on Form CMS-209. Findings include: 1. A review of the laboratory's Form CMS-209 revealed the Laboratory Director was also serving as the Technical Consultant. 2. A review of the laboratory's personnel files revealed a lack of documentation of at least 1 year of laboratory training or experience in the subspecialties of routine chemistry and endocrinology. 3. An interview on 5/15/23 at 12:53 pm with the Laboratory Director confirmed documentation to qualify as a Technical Consultant for routine chemistry and -- 10 of 11 -- endocrinology was not present. 4. The laboratory was given an additional 7 days to provide documentation showing the Technical Consultant met the qualification requirements and it was not made available. D6056 CLINICAL CONSULTANT CFR(s): 493.1415 The laboratory must have a clinical consultant who meets the qualification requirements of 493.1417 of this part and provides clinical consultation in accordance with 493.1419 of this part. This CONDITION is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to employ a qualified clinical consultant. Refer to D6057. D6057 CLINICAL CONSULTANT QUALIFICATIONS CFR(s): 493.1417 The clinical consultant must be qualified to consult with and render opinions to the laboratory's clients concerning the diagnosis, treatment and management of patient care. The clinical consultant must-- (a) Be qualified as a laboratory director under 493. 1405(b)(1), (2), or (3)(i); or (b) Be a doctor of medicine, doctor of osteopathy or doctor of podiatric medicine and possess a license to practice medicine, osteopathy or podiatry in the State in which the laboratory is located. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Director, the laboratory failed to employ a qualified clinical consultant for for 15 (5/1/23 to 5/15/23) of 15 days since the laboratory had started testing 5/1/23. Findings include: 1. A review of the laboratory's personnel records revealed a lack of documentation showing any laboratory personnel were qualified or serving the role of clinical consultant. 2. An interview on 5/15/23 at 10:04 am with the Laboratory Director revealed the laboratory had not employed a qualified clinical consultant. -- 11 of 11 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access