All Womens Health Center Of Orlando Inc

CLIA Laboratory Citation Details

2
Total Citations
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 10D0966025
Address 431 Maitland Ave, Altamonte Springs, FL, 32701
City Altamonte Springs
State FL
Zip Code32701
Phone(407) 834-2262

Citation History (2 surveys)

Survey - May 19, 2023

Survey Type: Standard

Survey Event ID: 6QZ611

Deficiency Tags: D0000 D5413

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was conducted on May 19, 2023. All Womens Health Center of Orlando INC clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on observation, record review, and interview, the laboratory failed to monitor the storage of two D (Rho) typing reagents: Anti-D and Ortho Bovine Albumin within manufacturer's guidelines for 12 (January -December) out of 12 months in 2022 and 4 (January -April) out of 4 months in 2023. Finding included: 1. During the tour of lab on 5/19/2023 at 9:51 AM, a small fridge was noted under the pregnancy testing station. The fridge contained 2 temperature gauges. One temperature gauge was on the top shelf and had no reading levels to identify if it was Fahrenheit or Celsius (C). The other temperature gauge was in the freezer part of the fridge, frozen in ice. It could not be moved and the temperature values were not visible. The fridge also stored the following reagents: Anti-D(lot number DB341A1), Ortho Bovine Albumin (lot number BA007A) and sterile water used for Rhesus(RH) factor testing. 2. Review of Blood Grouping Reagent Anti-D (Anti-Rh) (Murine Monoclonal-Polyclonal Blend Bioclone) for Rapid Tube, Slide and Microplate Tests manufacturer's instructions read, "Store at 2 to 8 Celsius." 3. Review of "RH Testing Log"revealed the following: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- a The fridge temperature was 2 C - 8 C. b. 12 (January -December) out of 12 months in 2022, the fridge temperature was documented above 8 degrees C. c. 4 (January - April) out of 4 months in 2023, the fridge temperature was noted above 8 degrees C. 4. During an interview on 5/19/2023 at 12:11 PM, the Administrator acknowledged the fridge temperatures were out of range for D (Rho) typing reagents storage requirements. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 31, 2019

Survey Type: Standard

Survey Event ID: TX7R11

Deficiency Tags: D2155

Summary:

Summary Statement of Deficiencies D2155 ABO GROUP AND D(RHO) TYPING CFR(s): 493.859(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to participate in proficiency testing (PT) that resulted in a score of zero percent (0%) for the Immunohematology analyte D (Rho) Typing for the first event in 2019. Findings: Review of the American Association of Bioanalysts (AAB) records for "Q1 Nonchemistry 2019" showed the laboratory received a score of "0.0 NR" (Not Reported to AAB) for the Immunohematology analyte D(Rho) Typing. During an interview on 5/31/19 at 1:25 PM, the Administrator acknowledged that the laboratory failed to get the test results submitted on time. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --