Allan Kurtz Do / Warner Medical Center

CLIA Laboratory Citation Details

5
Total Citations
24
Total Deficiencyies
16
Unique D-Tags
CMS Certification Number 05D0860502
Address 6325 Topanga Canyon Blvd, Ste 501, Woodland Hills, CA, 91367-2004
City Woodland Hills
State CA
Zip Code91367-2004
Phone818 346-1440
Lab DirectorALLAN DO

Citation History (5 surveys)

Survey - May 5, 2025

Survey Type: Special

Survey Event ID: YMGQ11

Deficiency Tags: D0000 D2130 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review survey was performed on 05/07/2025, the laboratory was found not in compliance with the following CONDITION LEVEL DEFICIENCIES D2016 - 42 C.F.R. 493.803 Condition: Successful participation [proficiency testing]; D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) - 0155D and American Proficiency Institute (API) records (2024-3 and Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- 2025-1), the laboratory failed to successfully participate in a proficiency testing program approved by HHS for each specialty, subspecialty and analyte or test in which the laboratory is certified under CLIA, the laboratory failed to successfully participate in the subspecialty of Hematology for the analyte Hematocrit (HCT) resulting in an unsuccessful performance. Refer to D2130. D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of Certification and Survey Provider Enhanced Reporting (CASPER) Report 0155D Individual Laboratory Profile and API evaluation reports, the laboratory failed to achieve satisfactory performance for two of three events proficiency events in 2024 and 2025 for analyte HCT. The laboratory received the following scores: 2024 third event - HCT 0%, 2025 first event - HCT 60%. A review of the 2024 and 2025 proficiency HCT scores from American Proficiency Institute confirmed the above findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on a proficiency testing desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) - 0155D report API records for 2024-3 and 202554-1 events, the laboratory director failed to provide overall management and a direction of the laboratory services. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a proficiency testing desk review of Certification and Survey Provider Enhanced Reporting (CASPER) - 0155D report API records for 2024-3 and 2025-1 events, the laboratory director failed to ensure successful participation in an HHS approved proficiency testing program. Refer to D2130. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 26, 2024

Survey Type: Standard

Survey Event ID: 7YWN11

Deficiency Tags: D2105 D6036 D2087 D6007

Summary:

Summary Statement of Deficiencies D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on the survey conducted on June 26, 2024, at approximately 1:00 p.m. and review of American Proficiency Institute (API) proficiency testing (PT) records, interviews with the technical consultant (TC) and laboratory assistant (LA), and review of five (5) randomly chosen chemistry patients records; it was determined that the laboratory failed to attain at least 80% of the acceptable score in routine chemistry for Chloride and Sodium analytes. The findings included: 1. Based on review of PT records for the second event of 2021 (Q2-2021), API reported an unsatisfactory score report as follow: Chloride PT Q2-2021 Overall score 60% Specimen Reported Expected CH-06 96 86 - 96 CH-07 101 91 - 102 CH-08 *113 101 - 112 CH-09 *110 98 - 109 CH-10 115 106 - 118 Sodium PT Q2-2021 Overall score 60% Specimen Reported Expected CH-06 127 123 - 131 CH-07 135 130 - 139 CH-08 146 144 - 153 CH-09 *193 139 - 148 CH-10 *150 151 - 160 2. The TC and LA affirmed on June 26, 2024 at approximately 1:00 p.m. that the laboratory obtained PT scores in statement #1. 3. According to the submitted laboratory testing declaration submitted on the day of the survey, the laboratory performed approximately 16,000 routine chemistry test samples including Chloride and Sodium during the time the laboratory had unsatisfactory proficiency testing results. Thus, the reliability and quality of chemistry patient results reported could not be assured. D2105 ENDOCRINOLOGY CFR(s): 493.843(e) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on review of the American Proficiency Institute (API) proficiency testing (PT) performance records,

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 16, 2019

Survey Type: Special

Survey Event ID: EPJV11

Deficiency Tags: D2016 D6000 D2107 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Endocrinology constituting unsuccessful PT performances. (See D2107) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2107 ENDOCRINOLOGY CFR(s): 493.843(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Free Thyroxine (FT4), resulting in an "non-initial" (subsequent) unsuccessful performance. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for the analyte, FT4, as follows: 2018 Q2 2019 Q1 2019 Q2 FT4 0% 0% 20% Q1 = First Testing Event Q2 = Second Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an subsequent unsuccessful performance for the analyte, FT4. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, FT4, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performances. (See D2016 and D2107) -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 22, 2019

Survey Type: Standard

Survey Event ID: QWB211

Deficiency Tags: D2087 D2121 D6019 D6070 D2098 D5217 D6021

Summary:

Summary Statement of Deficiencies D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on reviews second quarter (Q2-2018) of the American Proficiency Institute (API) proficiency testing performance summary records, random patient sampling test results, and interview with the technical consultant, it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for Creatinine. The findings included: a. Q2-2018, API reported a score of 40% for Creatinine analyte. b. For ten (10) out of ten (10) random patient sampling test results reviewed covering period from 10/2/2017 to 4/2/2019, the laboratory analyzed and reported Creatinine tests during the approximate time the laboratory received the failed proficiency score. c. The technical consultant confirmed (4/22/2019, 1245) that the laboratory received that above unsatisfactory proficiency testing score. D2098 ENDOCRINOLOGY CFR(s): 493.843(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on reviews second quarter (Q2-2018) of the American Proficiency Institute (API) proficiency testing performance summary records, random patient sampling test results, and interview with the technical consultant, it was determined that the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- laboratory failed to attain a score of at least 80 percent of acceptable responses for Free Thyroxine. The findings included: a. Q2-2018, API reported a score of 0% for Free Thyroxine analyte. b. For two out of two (2) random patient sampling test results reviewed covering period from 10/1/2018 and 1/2/2019, the laboratory analyzed and reported Free Thyroxine approximately during the time the laboratory received the failed proficiency testing score. c. The technical consultant confirmed (4/22/2019, 1245) that the laboratory received that above unsatisfactory proficiency testing score. D2121 HEMATOLOGY CFR(s): 493.851(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on reviews third quarter (Q3-2017) of the American Proficiency Institute (API) proficiency testing performance summary records, random patient sampling test results, and interview with the technical consultant, it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for Monocytes. The findings included: a. Q3-2017, API reported a score of 60% for Monocytes analyte. b. For eleven (11) out of eleven (11) random patient sampling test results reviewed covering period from 10/2/2017 to 4/2/2019, the laboratory analyzed and reported Complete Blood Count (CBC) tests which included Monocytes. c. The technical consultant confirmed (4/22/2019, 1245) that the laboratory received that above unsatisfactory proficiency testing score. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on reviews of the American Proficiency Institute (API) proficiency testing performance summary records, and interview with the technical consultant, it was determined that the laboratory failed to least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. The findings included: a. API reported the following unsatisfactory proficiency testing scores. Hematology Analyte: Score: Event/Year ESR 50% Q1- 2017 MCHC 40% Q1-2018 MCV 0% Q1-2018 RDW-SD 0% Q1-2018 RDW-SD 0% Q2-2018 Endocrinology Analyte: Score: Event/Year SHBG 20% Q1-2018 Testo 20% Q1-2018 (SHB) Testo, Free 0% Q1-2018 Testo, Free 0% Q2-2018 Abbreviation: ESR= Erythrocyte Sedimentation Rate MCHC= Mean Corpuscular Hemoglobin Concentration MCV= Mean Corpuscular Volume RDW= Red Cell Distribution SHBG= Sex Hormone Binding Globulin Testo= Testosterone b. Based on the laboratory's annual test volume submitted, the laboratory analyzed and reported approximately 200 ESR tests and 200 Testosterone and SHBG tests during the approximately time that the laboratory received the above unsatisfactory proficiency testing scores. c. The technical consultant confirmed (4/22/2019, 1245) that the laboratory received the above unsatisfactory proficiency testing scores. -- 2 of 3 -- D6019 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iv) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iv) Ensure that an approved

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 5, 2019

Survey Type: Special

Survey Event ID: ULSC11

Deficiency Tags: D2107 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Endocrinology constituting unsuccessful PT performance. (See D2107) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2107 ENDOCRINOLOGY CFR(s): 493.843(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Free thyroxine (free T4), resulting in an "initial" (first) unsuccessful performance. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for the analyte, free T4 as follows: 2018 Q2 2019 Q1 free T4 0% 0% Q1 = First Testing Event Q2 = Second Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an initial unsuccessful performance for the analyte, free T4. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, free T4, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performance. (See D2016 and D2107) -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access