Alley Medical Center Laboratory

CLIA Laboratory Citation Details

1
Total Citation
4
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 39D0669942
Address 301 West 3rd Street, Berwick, PA, 18603
City Berwick
State PA
Zip Code18603
Phone(570) 759-0351

Citation History (1 survey)

Survey - November 20, 2018

Survey Type: Standard

Survey Event ID: 9XAL11

Deficiency Tags: D5209 D6051 D5209 D6051

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based of review of laboratory's personnel evaluation procedure and interview with the testing personnel (TP) #1, the laboratory failed establish a complete procedure on how to assess testing personnel and consultant competency from 04/19/2017 to the time of survey. Findings include: 1. On the day of survey, 11/20/2018, the laboratory failed to provide a complete written policy that reviews how to assess the competency of laboratory testing personnel and the competency of consultant's regulatory responsibilities. 2. The TP #1 confirmed the findings at the time of survey, 11/20/2018 around 10:00 am. D6051 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8)(v) The procedures for evaluation of the competency of the staff must include, but are not limited to assessment of test performance through testing previously analyzed specimens, internal blind testing samples or external proficiency testing samples. This STANDARD is not met as evidenced by: Based on, the review of personnel competency assessment records, American Proficiency Institute (API) proficiency testing (PT) records and interview with the technical consultant #2, the Technical Consultant failed to assess the competency of 3 of 4 testing personnel (TP) through internal blind testing samples or external PT Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- samples for chemistry and hematology testing in 2017. Findings Include: 1. On the day of survey, 11/20/2018, review of personnel competency assessments and API attestation forms revealed the laboratory did not assess the test performance of 3 of 4 TP through internal blind testing samples or external PT samples in 2017 for Chemistry on the Alfa Wasserman Ace Alera, Tosoh A1A 360 and Hematology on the Sysmex KX 21. 2. TP #1 was the only personnel performing in 2017 API PT evaluations. 3. TP#1 confirmed the findings above on 10/20/2018 around 10:30 am. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access