Alveoli Corpporation Dba Lungs At Work

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 39D1005462
Address 5000 Waterdam Plaza Drive, Suite 180, Mcmurray, PA, 15317
City Mcmurray
State PA
Zip Code15317
Phone(724) 941-1650

Citation History (2 surveys)

Survey - July 18, 2024

Survey Type: Standard

Survey Event ID: YFJN11

Deficiency Tags: D2093 D2088

Summary:

Summary Statement of Deficiencies D2088 ROUTINE CHEMISTRY CFR(s): 493.841(b) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) records and interview with Testing Personnel (TP) #2, the laboratory failed to attain an overall testing event score of at least 80 percent for 1 of 3 chemistry testing events in 2023. Findings include: 1. On the day of survey 7/18/2024 at 12:30 pm, review of the laboratory's API PT records revealed the laboratory scored a zero percent (0%) for each of the following analytes in the 2nd event of 2023: - pCO2, pH, pO2, Carboxyhemoglobin, Hemoglobin, Methemoglobin and Oxyhemoglobin. 2. The laboratory failed to obtain an overall testing event score of at least 80 percent and resulted in unsatisfactory performance for the 2nd API PT event of blood gas analysis in 2023. 3. TP #2 confirmed the findings above on 7/18/2024 at 1:05 pm. D2093 ROUTINE CHEMISTRY CFR(s): 493.841(d) Failure to return proficiency testing results to the proficiency testing program within the time frame specified by the program is unsatisfactory performance and results in a score of 0 for the testing event. This STANDARD is not met as evidenced by: Based on review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) records and interview with Testing Personnel (TP) #2, the laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- failed to return PT results to API within the timeframe specified for 1 of 3 chemistry testing events in 2023. Findings include: 1. On the day of survey 7/18/2024 at 12:30 pm, review of the laboratory's API PT records revealed the laboratory failed to participate and resulted in an unsatisfactory performance score of zero for the 2nd event of blood gas analysis in 2023. 2. Interview with TP #2 on 7/18/2024 at 1:05 pm confirmed the laboratory failed to return PT results to API within the specified timeframe for the 2nd event in 2023. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 6, 2022

Survey Type: Standard

Survey Event ID: Q0NZ11

Deficiency Tags: D5421 D6046 D6046 D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of the Gem 5000 Blood Gas analyzer validation records and interview with Testing Personnel (TP)#1, the laboratory failed to establish criteria for acceptable performance specifications for the Gem 5000 Blood Gas analyzer validation used for routine chemistry specimens from December 17, 2021 to December 06, 2022. Findings Include: 1. On the day of the survey, 12/06/2022 at 12: 35pm, review of the Gem 5000 Blood Gas analyzer validation records revealed that the validation performed on 12/17/2021 did not include criteria for acceptable precision, accuracy, and reportable range. 2. TP#1 confirmed the findings above on 12 /06/2022 around 01:25pm. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on review of the laboratory competency assessment records and interview with Testing Personnel (TP)#1, the Technical Consultant (TC) failed to evaluate the competency assessment of 2 of 2 Testing Personnel (TP) who performed Blood Gas examinations in 2021 and 2022. Findings include: 1. On the day of survey 12/06/2022 at 11:51 am, the laboratory could not provide competency assessment records performed by the TC for 2 of 2 TP (CMS 209 personnel #2 and#3) who performed Blood Gases in 2021 and 2022. 2. TP#1 confirmed the finding above on 12/06/2022 at 01:25 pm. -- 2 of 2 --