Amg Hematology & Oncology

CLIA Laboratory Citation Details

4
Total Citations
32
Total Deficiencyies
13
Unique D-Tags
CMS Certification Number 31D2154847
Address 1000 Galloping Hill Road, Union, NJ, 07083
City Union
State NJ
Zip Code07083
Phone908 608-0078
Lab DirectorNEIL MORGANSTEIN

Citation History (4 surveys)

Survey - July 23, 2025

Survey Type: Standard

Survey Event ID: WJ8511

Deficiency Tags: D5221 D5211 D5807 D5791 D5221 D5791 D5807

Summary:

Summary Statement of Deficiencies D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to review and evaluate PT results obtained from the College of American Pathologists (CAP) for Hematology tests from 9/1/23 to 7/23/25. The findings include: 1. There was no documented evidence that PT results obtained from CAP for Hematology events FH9-C-23, FH9-B-24, BCP-B- 24, FH9-C-24 and BCP-C-24 were reviewed and evaluated. 2. The CAP PT results for FH9-C-23, FH9-B-24, BCP-B-23, FH9-C-24 and BCP-C-24 were printed on site during the survey by the TP. 3. Code 26 (educational challenge) results for Immature Granulocytes (IG) % and IG Absolute for PT event FH9-A-25 were not reviewed or evaluated. 4. TP #1 as listed on the CMS 209 form confirmed on 7/23/25 at 12:10 pm, the laboratory did not review and evaluate all PT results obtained from CAP. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to review all unsatisfactory scores and document

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 3, 2023

Survey Type: Standard

Survey Event ID: LY6311

Deficiency Tags: D5221 D5437 D5783 D6021 D6021 D3037 D5221 D5437 D5783

Summary:

Summary Statement of Deficiencies D3037 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(4) Proficiency testing records. Retain all proficiency testing records for at least 2 years. This STANDARD is not met as evidenced by: Based on surveyor review of Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to retain graded results for Hematology auto differentials performed with the College of American Pathologists (CAP). The findings include: 1) There were no Graded results for all PT events in 2021. 2) The TP confirmed on 5/3/23 at 10:15 am that all PT graded results were not retained. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Testing Personnel (TP) the laboratory failed to review coded results for Hematology Testing performed with the College of American Pathologists (CAP) in the first event of 2022. The findings include:. The finding include: 1. The laboratory received a coded result (Code 26 -Educational Challenge) for Blood Cell ID upgraded for event FH9-A 2022. 2. There was no documented evidence that coded PT results were reviewed. 3. The TP confirmed on 5/3/23 at 10:15 am that the laboratory did not review coded PT results. D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on surveyor review of Calibration (CAL) records, Procedure Manual (PM) and interview with the Testing Personnel (TP), the laboratory failed to perform and document Calibration procedures at least once every six months for Hematology Tests performed on the Sysmex XN-L 430 analyzer from 8/16/21 to the date of survey. The findings include: 1. A review of Cal records revealed that the laboratory last performed CAL 8/16/21. 2. The TP confirmed on 5/3/23 at 11:32 am that the laboratory failed to perform and document Cal once every six months. D5783

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 21, 2021

Survey Type: Standard

Survey Event ID: GDWL11

Deficiency Tags: D6018 D6021 D6018 D6021

Summary:

Summary Statement of Deficiencies D6018 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iii) Ensure that all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 1, 2019

Survey Type: Standard

Survey Event ID: ZDE711

Deficiency Tags: D5209 D5211 D6013 D6021 D6029 D6074 D6074 D5209 D5211 D6013 D6021 D6029

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on survey review of the Competency Assessment (CA) records and interview with the Testing Personnel (TP), the laboratory failed to follow its Competency Assessment (CA) procedures for five out of five TP from 10/2/18 to the date of the survey. The findings include: 1. The laboratory failed to use all the criteria in the CA procedure as follows: a. Four of five TP did not have assessment of test performance through testing Proficiency Samples or internal blind samples performed b. Three of five TP did not have direct observation of instrument maintenance or problem solving skills evaluated. c. One of five TP did not have any of the criteria used to assess CA. 2. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 12:30 pm the laboratory did not follow the CA procedure. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to evaluate coded results obtained in the FH9-A 2019 Hematology Auto Differential event with the College of American Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Pathologists (CAP). The findings include: 1. The laboratory did not evaluate Code 27 (lack of participant or referee consensus) and Code 26 (educational challenge) obtained for Blood Cell Identification in the FH9-A 2019 event. 2. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 1:30 pm that the laboratory failed to evaluate coded results for PT events. D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; This STANDARD is not met as evidenced by: Based on surveyor review of the Performance Specification (PS) records and interview with the Testing Personnel (TP), the Laboratory Director (LD) failed to ensure that PS procedures performed on the Sysmex XN-430 analyzer were adequate from October 2018 to the date of survey. The findings include: 1. The LD did not review and sign the Method Comparison (MC) results. 2. There were no documented evidence linearity was performed. 3. There was no work records to substantiate the reportable range study. 4, There was no documented evidence precision was reviewed by the LD. 5. There was no documented evidence the reference range was verified. 6. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 2:15 pm that PS records were not adequate. D6021 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that quality assessment programs are established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on lack of a Quality Assessment (QA) policy and interview with the Testing Personnel (TP), the Laboratory Director failed to ensure that a QA program was established from 10/2/08 to the date of survey. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 2:00 pm that the laboratory did not have a QA program. D6029 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(11) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently -- 2 of 3 -- and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(11) Ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results. This STANDARD is not met as evidenced by: Based on surveyor review of the Personnel Files (PF) and interview with the Testing Personnel (TP), the Laboratory Director failed to have appropriate training records for five out of six TP on file from 10/2/18 to the date of the survey. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 1:40 am all training records were not in the PF. D6074 TESTING PERSONNEL RESPONSIBILITIES CFR(s): 493.1425(b)(5) Each individual performing moderate complexity testing must be capable of identifying problems that may adversely affect test performance or reporting of test results and either must correct the problems or immediately notify the technical consultant, clinical consultant or director. This STANDARD is not met as evidenced by: a. Based on surveyor review of the Quality Control (QC) records and interview with the Testing Personal (TP), the TP failed to identify problems that may affect test performance by not reviewing and evaluating trends and/or shifts for tests performed on the Sysmex XN-430 analyzer from 10/2/18 to the date of the survey. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 1:45 pm that trends and shifts were not reviewed. b. Based on surveyor review of the QC records and interview with the TP, the TP were not able to accurately identify problems that may affect test performance by not having the correct values to review and evaluate trends and/or shifts for tests programmed into the Sysmex XN-430 analyzer from 10/2/18 to the date of the survey. The finding includes: 1. A review of the QC Levy Jennings Charts in the instrument revealed that standard deviations from the mean were not calculated correctly. 2. The TP #3 listed on CMS form 209 confirmed on 5/1/19 at 1:45 pm that trends and shifts were not able to be reviewed accurately. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access