Amg Medical Pllc

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 23D2073817
Address 840 E Mount Hope Avenue, Lansing, MI, 48910
City Lansing
State MI
Zip Code48910
Phone(517) 327-5220

Citation History (1 survey)

Survey - March 7, 2023

Survey Type: Standard

Survey Event ID: PBT011

Deficiency Tags: D5417 D5417 D5400

Summary:

Summary Statement of Deficiencies D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on record review and interview with Technical Consultant #2, the laboratory failed to meet applicable analytic system requirements and correct identified problems. Findings include: 1. The laboratory failed to ensure controls used in urine toxicology testing were not used beyond their expiration date. Refer to D5417. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: . Based on observation and interview with Technical Consultant #2, the laboratory failed to ensure controls used in urine toxicology testing were not used beyond their expiration date for 1 of 8 reagents observed. Findings include: 1. The surveyor observed during a tour of the laboratory on 3/07/2023 at 8:52 am, the Buprenorphine controls in the Magic Chef refrigerator with an expiration date of 1/31/2023. 2. When Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- queried on 3/07/2023 at 10:30 am, Technical Consultant #2 reviewed the patient testing logs to find that 62 patients had toxicology testing with Buprenorphine results on 3/01/2023. 3. An interview on 3/07/2023 at 10:30 am, Technical Consultant #2 confirmed the Buprenorphine controls were expired and had been used in urine toxicology testing beyond their expiration date. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access