Andrew L Simon Md Facs Pa

CLIA Laboratory Citation Details

1
Total Citation
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 31D1006255
Address 459 Jack Martin Blvd Suite 3, Brick, NJ, 08724
City Brick
State NJ
Zip Code08724
Phone(732) 840-0900

Citation History (1 survey)

Survey - July 13, 2021

Survey Type: Standard

Survey Event ID: UQ6I11

Deficiency Tags: D5629 D5645 D5643 D6130

Summary:

Summary Statement of Deficiencies D5629 CYTOLOGY CFR(s): 493.1274(c)(5) (c) Control procedures. The laboratory must establish and follow written policies and procedures for a program designed to detect errors in the performance of cytologic examinations and the reporting of results. The program must include the following: (c) (5) An annual statistical laboratory evaluation of the number of - (c)(5)(i) Cytology cases examined; (c)(5)(ii) Specimens processed by specimen type; (c)(5)(iii) Patient cases reported by diagnosis (including the number reported as unsatisfactory for diagnostic interpretation); (c)(5)(iv) Gynecologic cases with a diagnosis of HSIL, adenocarcinoma, or other malignant neoplasm for which histology results were available for comparison; (c)(5)(v) Gynecologic cases where cytology and histology are discrepant; and (c)(5)(vi) Gynecologic cases where any rescreen of a normal or negative specimen results in reclassification as low-grade squamous intraepithelial lesion (LSIL), HSIL, adenocarcinoma, or other malignant neoplasms. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual and interview with the Office Manager (OM), the laboratory failed to establish a written procedure which included number of cytology cases examined, specimens processed by type and patient cases reported by diagnosis (including the number reported as unsatisfactory for diagnostic interpretation) from 8/15/18 to the date of the survey. The OM confirmed on 7/13/21 at 12:30 pm the laboratory did not have the above procedure. D5643 CYTOLOGY CFR(s): 493.1274(d)(2)(iii) (d) Workload limits. The laboratory must establish and follow written policies and procedures that ensure the following: (d)(2)(iii) Nongynecologic slide preparations made using liquid-based slide preparatory techniques that result in cell dispersion over Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- one-half or less of the total available slide may be counted as one-half slide; and (d)(2) (iv) Technical supervisors who perform primary screening are not required to include tissue pathology slides and previously examined cytology slides (gynecologic and nongynecologic) in the 100 slide workload limit. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and interview with the Office Manager (OM), the laboratory failed to establish workload limits for personnel reading nongynecology slides from 8/15/18 to the date of the survey. The OM confirmed on 7/13/21 at 12:30 pm that workload limits were not established. D5645 CYTOLOGY CFR(s): 493.1274(d)(3) (d) Workload limits. The laboratory must establish and follow written policies and procedures that ensure the following: (d)(3) The laboratory must maintain records of the total number of slides examined by each individual during each 24-hour period and the number of hours spent examining slides in the 24-hour period irrespective of the site or laboratory. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual and interview with the Office Manager (OM), the laboratory failed to establish a procedure for maintaining records of the total number of slides reviewed in 24 hours from 8/15/18 to the date of the survey. The OM confirmed on 7/13/21 at 12:30 pm that the above mentioned procedure was not established. D6130 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(c)(2)(3) (c) In cytology, the technical supervisor or the individual qualified under 493.1449(k) (2)-- (c)(2) Must establish the workload limit for each individual examining slides and (c)(3) Must reassess the workload limit for each individual examining slides at least every 6 months and adjust as necessary. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual and interview with the Office Manager (OM), the Laboratory Director failed to establish the work load limit for examining slides and to reassess the work load limit every six months on the day of the survey. The OM confirmed on 7/13/21 at 12:30 pm that work load limits were not established. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access