Arielle N B Kauvar Md Pc

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 33D1013071
Address 1044 Fifth Avenue, New York, NY, 10028
City New York
State NY
Zip Code10028
Phone212 249-9440
Lab DirectorARIELLE KAUVAR

Citation History (2 surveys)

Survey - February 14, 2023

Survey Type: Standard

Survey Event ID: U4EE11

Deficiency Tags: D5417 D6076 D6094 D5417 D6076 D6094

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on direct observation of the Tissue Tek Embedding O.C.T., Rapid Differential bottles, Gills Hematoxylin stain, Bluing Solution, and confirmed via phone with the Moh's technician, the laboratory failed to ensure that stains and embedding material used for Moh's slides did not exceed the expiration dates. FINDINGS: The surveyor confirmed on February 14, 2023, at 11:00 A.M. through direct observation that the following materials were used in Moh's processing after the expiration dates: 1. Gills Hematoxylin stain (1/2 gallon), Lot #122924, Expiration date 12/31/22. 2. Bluing Solution (1/2 gallon), Lot # 113536, Expiration date 12/21/22. 3. Tissue Tek Embedding O.C.T. medium, Lot #1170-00, Expiration date 7/31/22 including eleven 4 oz bottles located under the sink and one 4 oz bottle located on top of the cryostat. 4. Approximately fifteen patient samples were processed and Moh's slide results were reported from 12/31/22 through 1/30/23. D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Based on direct observation, the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 22, 2019

Survey Type: Standard

Survey Event ID: WK4W11

Deficiency Tags: D5413 D5417 D5413 D5417 D6094 D6094

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on a lack of humidity records and an interview with the Moh's processor, the laboratory failed to follow the manufacturer's instructions to monitor and document the humidity. Findings Include: The Moh's processor confirmed on February 22, 2019, at approximately 10:00 AM that the laboratory failed to follow the manufacturer's directions to monitor and document the humidity of the room where Moh's processing occurs from July 2017 through the date of this survey. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on surveyor's observation of the reagents used for Moh's slide staining, and an interview with the Moh's processor, the laboratory failed to discontinue the use of the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- expired histological reagent. Findings Include: It was confirmed with the Moh's processor on February 22, 2019 at approximately 10:25 am, the laboratory failed to discard the expired reagents: Eosin Lot # 054145 - expired 11/2018. Approximately 13 patient specimens were tested and results released during that time. D6094 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on a review of procedures and an interview with the Moh's processor, the laboratory director failed to ensure that the laboratory's QA program was maintained as part of the laboratory's overall quality systems program. Refer to D5413 and D5417 -- 2 of 2 --