Arkansas Dermatology

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 04D2178013
Address 106 S Inglewood, Suite B, Russellville, AR, 72801
City Russellville
State AR
Zip Code72801
Phone(479) 223-5000

Citation History (2 surveys)

Survey - February 24, 2023

Survey Type: Standard

Survey Event ID: Q6KI11

Deficiency Tags: D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Through observation, and interview it was determined that the laboratory failed to monitor the temperature in one of one room in which supplies with storage temperature requirements were stored on each day of operation. Findings follow: A) During a tour of the laboratory on 2/24/23 at 12:13 p.m.one room (dermatology lab) containing items with a temperature storage requirement was observed. B) During a review of the laboratory's temperature records it was noted that temperature records were presented for the dermatology lab room. C) During a tour of the laboratory on 2 /24/23 at 12:13 p.m. one container of Tissue - Tek O.C.T. compound (lot # 3482-00 expiration date 5/31/2024) with a storage temperature requirement of 15 degrees C. to 30 degrees C were observed in the dermatology lab room. D) Upon request, the laboratory could not present the location of the thermometer in the dermatology lab room with a closeable door from the hallway which the supplies identified above were stored. E) In an interview on 2/24/23 at 12:13 p.m. the laboratory staff member (# 8 on CMS 209 form) stated that the daily temperature of the dermatology lab are recorded using the thermostat located in the hall way. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 5, 2021

Survey Type: Standard

Survey Event ID: MRTV11

Deficiency Tags: D5413 D5473 D5433

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Through a review of Room Temperature Logs for January 2020 through January 2021, lack of documentation, and an interview with laboratory staff, it was determined the laboratory failed to document room temperature on eleven of fourteen days of operation in June 2020. Survey findings follow: A. In a review of the Room Temperature Log for June 2020, it was revealed that on eleven of fourteen days the room temperature was documented by a "check mark". Actual laboratory temperature is not documented on the eleven days of operation. B. At 11:27 a.m. on 2/5/2021, laboratory employee #8 (as listed on the Employee Identification Form) confirmed the lack of documented room temperatures on the eleven days of operation in June 2020. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. This STANDARD is not met as evidenced by: Through a review of the Cryostat Maintenance Logs and Microscope Maintenance Logs for January 2020 through January 2021, patient logs for Mohs and frozen sections, Frozen (Excision) Pathology Reports for two patients, and through interviews with laboratory staff, it was determined the laboratory failed to document maintenance on the microscope and cryostat in December 2020 on two of two days that the laboratory was in operation. Survey findings include: A. Cryostat Maintenance Logs and Microscope Maintenance Logs are used to document all daily cleaning and maintenance of the cryostat and microscope used for histopathology in Mohs surgical cases and frozen section biopsies. B. The surveyor reviewed patient logs for Mohs and biopsies with frozen sections and determined patients were reported on two days in December. Two patient final reports were reviewed for Frozen (Excision) Pathology. Pathology # RV20-323 was received and reported on 12 /14/2020 and Pathology # RV 20-331 was received and reported on 12/28/2020. C. There is no documented daily cleaning or maintenance of the microscope or cryostat on 12/14/2020 or 12/28/2020 when patients were tested. D. At 11:27 a.m. on 2/5/2021 laboratory employee #8 (as listed on the Employee Identification Form) confirmed the lack of documented maintenance in December 2020. D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Through a review of the monthly Quality Control Log: Daily Worksheets for Toluidine Blue stain, a review of patient test records for December, and interviews with laboratory staff, it was determined the laboratory failed to document stain quality on one of two days in which patient histopathology slides were stained and examined. Survey finding include: A. Quality Control Log: Daily Worksheets for Toluidine Blue stain are used to document the daily stain quality and any

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access