Arthritis And Rheumatism Associates Pl

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 10D0893127
Address 612 Druid Rd E, Clearwater, FL, 33756
City Clearwater
State FL
Zip Code33756
Phone(727) 443-6400

Citation History (2 surveys)

Survey - July 30, 2018

Survey Type: Standard

Survey Event ID: HKOU11

Deficiency Tags: D5213 D5791 D5209 D5459

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on record review and interview with Testing Person #B the laboratory failed to perform the 6 month competency evaluations on 2 out of 2 (#B and #C) new Testing Personnel. Findings Included: Review of competency evaluations found no competency evaluations for Testing Person #B and #C. During an interview on 07/30 /18 at 10:34 AM, Testing Person #B confirmed that no 6 month competency evaluations had been performed for Testing Person #B and #C. D5213 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(1) The laboratory must verify the accuracy of any analyte or subspecialty without analytes listed in subpart I of this part that is not evaluated or scored by a CMS- approved proficiency testing program. This STANDARD is not met as evidenced by: Based on review of API (American Proficiency Institute) proficiency testing and interview with Testing Person #C the laboratory failed to evaluate ungraded results in proficiency testing for 2 (3rd testing event in 2016 and 2nd testing event in 2017) out of 5 (1st testing event in 2018, 1st, 2nd, 3rd testing event in 2017, and 3rd testing event 2016) testing events for Monocytes. Findings Included: Review of API proficiency testing results in the 2nd testing event for 2017 found 2 out of 5 scores for Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Monocytes were ungraded with no

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 20, 2018

Survey Type: Special

Survey Event ID: CRWV11

Deficiency Tags: D2016 D6076 D2085 D6089

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the laboratory's proficiency testing records for 2017, the laboratory did not have successful performance in proficiency testing for the specialty of general immunology. Refer to D2085. Findings include: Review of the American Proficiency Institute (API) proficiency testing records and the review of the Centers for Medicare & Medicaid Services (CMS) 153 and 155 reports, on February 20, 2018, on or about 10:00 AM, showed that the laboratory had unsatisfactory testing scores for the analyte, anti-nuclear antibodies (ANA) for two consecutive testing events in 2017. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D2085 GENERAL IMMUNOLOGY CFR(s): 493.837(g) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on the review of the Centers for Medicare & Medicaid Services (CMS) 153 and 155 reports and the laboratory's proficiency testing records, the laboratory did not have successful participation in proficiency testing for the specialty of general immunology. Findings include: On February 20, 2018 on or about 10:00 AM the American Proficiency Institute (API) proficiency testing records and the CMS 153 and 155 reports were reviewed. The review showed that the laboratory failed to achieve satisfactory performance for the analyte, anti-nuclear antibodies, ANA, as shown below. Event #2, 2017 ANA-40% Event #3, 2017 ANA-0% D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: Based on the review of the laboratory's proficiency testing records, the laboratory director failed to ensure that the laboratory maintained a satisfactory score for proficiency testing in the specialty of general immunology. Findings include: On February 20, 2018, on or about 10:00 AM, the American Proficiency Institute (API) proficiency records and the Centers for Medicare & Medicaid Service (CMS) 153 and 155 reports were reviewed. The review showed that the laboratory had unsatisfactory testing scores for two consecutive testing events for the analyte, anti-nuclear antibodies (ANA), in the specialty of general immunology. The laboratory director is responsible for ensuring that the laboratory maintains successful participation in proficiency testing. Refer to D2085. D6089 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(i) The laboratory director must ensure the proficiency testing samples are tested as required under subpart H of this part. This STANDARD is not met as evidenced by: Based on the review of the laboratory's proficiency testing scores, the laboratory director failed to ensure that the laboratory performed proficiency testing in such a manner as to achieve and maintain successful participation in proficiency testing in the specialty of general immunology. Findings Include: The review of the American proficiency Institute (API) proficiency testing records and the Centers for Medicare & -- 2 of 3 -- Medicaid Services (CMS) 153 and 155 reports on February 20, 2018 on or about 10: 00 AM showed that the laboratory received unsatisfactory proficiency testing scores as shown below. Event #2, 2017 ANA-40% Event #3, 2017 ANA-0% -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access