Artius Dermatology Associates, Pc

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 05D2140871
Address 573 W Putnam Ave, Porterville, CA, 93257
City Porterville
State CA
Zip Code93257
Phone(559) 781-1812

Citation History (2 surveys)

Survey - August 20, 2024

Survey Type: Standard

Survey Event ID: 25LZ11

Deficiency Tags: D0000

Summary:

Summary Statement of Deficiencies D0000 THE LABORATORY IS IN COMPLIANCE WITH THE REQUIREMENTS OF 42 CFR PART 493; REQUIREMENTS FOR CLINICAL LABORATORIES. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 19, 2021

Survey Type: Standard

Survey Event ID: JIWX11

Deficiency Tags: D5217 D6094 D5891

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of patients test records, the lack of laboratory documents, and interview with a laboratory person, it was determined that the laboratory had failed to verify the accuracy of Mohs procedures in 2019 - 2020. Findings included: 1. The laboratory's Mohs Log and records registered procedures performed in 2019, 2020, to present 2021. 2. The laboratory was unable to provide for review 2019 and 2020 documents verifying the accuracy of the Mohs procedures to clear tumor at final stage. 3. The laboratory person affirmed (8/19/21 @ 4pm) the aforementioned lack of laboratory documents and that the laboratory policy required at least twice annual review of Mohs slides by a dermatopathologist. 4. And thus the reliability and quality of Mohs procedures performed in 2019 and 2020 could not be assured. Based on the stated annual test volumes (CMS116, 8/18/21), the laboratory performed approximately 400 Mohs procedures annually. D5891 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems specified in 493.1291. This STANDARD is not met as evidenced by: Based on review of patients electronic medical records (Visit Notes) and laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Mohs records and slides, and interview with a laboratory person, it was determined that the laboratory failed to maintain an ongoing postanalytic process to monitor and assess records and slides for discrepancies, and correct problems as they occur. Findings included: 1. On 3/19/20, Mohs procedures were performed on the patient RH: a. the Mohs maps and slides recorded the following: Slide # Site -------------------------------------------------- 20 - 26 Left Anterior Crown 20 - 27 Central Anterior Crown 20 - 28 Left Posterior Crown 20 - 29 Left Central Crown b. the Visit Note, "Mohs Operative Note" failed to match the Maps and Slides: 1. (the Mohs Case Number was not stated) Right superior medial forehead 2. Mohs Case Number: 20- 26 Left superior medial forehead 3. Mohs Case Number: 20- 29 Left superior parietal scalp 4. Mohs Case Number: 20- 28 Left central parietal scalp 2. On 2/11/21, Mohs procedures were performed on the patient DB: a. the Mohs maps recorded the following: Slide # Site Stages ----------------------------------------------------- 21 - 22 Left Medial Forehead III 21 - 23 Right Postauricular Crease I b. The label of 1 out of 5 Mohs slides failed to match the Mohs map. The slide was orginally labeled as "L med FH, 21- 22", but was crossed out and relabeled as "R post aur crease, II, 21- 23". 3. The laboratory person affirmed (8/19/21 @ 5pm) the aforementioned findings identified errors post-Mohs surgeries. And thus, the laboratory had failed to maintain an ongoing process to assure the quality of records after Mohs surgeries were completed. 4. The reliability and quality of the medical records, "Mohs Operative Note", and slide labels could not be assured. Based on the stated annual test volume, the laboratory performed approximately 400 Mohs procedures annually. D6094 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on findings and cumulative deficiencies cited, the Laboratory Director is herein cited for deficient practice in ensuring quality assessment processes were maintained to assure quality and identify failures as they occur. Findings included: 1. The Laboratory Director was deficient in monitoring and identifying failures to at least twice annually verify the accuracy of Mohs procedures performed. 2. The Laboratory Director was deficient in monitoring, assessing, identifying, and addressing errors in postanalytic records of completed Mohs procedures. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access