Associated Pathologists, Llc

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 44D2243577
Address 2170 Business Center Drive, Suite 17, Memphis, TN, 38134
City Memphis
State TN
Zip Code38134
Phone(615) 221-4400

Citation History (2 surveys)

Survey - May 30, 2024

Survey Type: Standard

Survey Event ID: T3UX11

Deficiency Tags: D6168 D6171 D6171

Summary:

Summary Statement of Deficiencies D6168 TESTING PERSONNEL CFR(s): 493.1487 The laboratory has a sufficient number of individuals who meet the qualification requirements of 493.1489 of this subpart to perform the functions specified in 493. 1495 of this subpart for the volume and complexity of testing performed. This CONDITION is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid Services Laboratory Personnel Report (CLIA) (Form CMS 209), review of education documents, review of a patient test report, and staff interview, testing person two did not qualify as a high- complexity testing person (Refer to D6171). D6171 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1489(b) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located or have earned a doctoral, master's or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; (b)(2)(i) Have earned an associate degree in a laboratory science, or medical laboratory technology from an accredited institution or-- (b)(2)(ii) Have education and training equivalent to that specified in paragraph (b)(2)(i) of this section that includes-- (b)(2)(ii)(A) At least 60 semester hours, or equivalent, from an accredited institution that, at a minimum, include either-- (b)(2)(ii)(A)(1) 24 semester hours of medical laboratory technology courses; or (b)(2)(ii)(A)(2) 24 semester hours of science courses that include-- (b)(2) (ii)(A)(2)(i) Six semester hours of chemistry; (b)(2)(ii)(A)(2)(ii) Six semester hours of biology; and (b)(2)(ii)(A)(2)(iii) Twelve semester hours of chemistry, biology, or medical laboratory technology in any combination; and (b)(2)(ii)(B) Have laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- training that includes either of the following: (b)(2)(ii)(B)(1) Completion of a clinical laboratory training program approved or accredited by the ABHES, the CAHEA, or other organization approved by HHS. (This training may be included in the 60 semester hours listed in paragraph (b)(2)(ii)(A) of this section.) (b)(2)(ii)(B)(2) At least 3 months documented laboratory training in each specialty in which the individual performs high complexity testing. (b)(3) Have previously qualified or could have qualified as a technologist under 493.1491 on or before February 28, 1992; (b) (4) On or before April 24, 1995 be a high school graduate or equivalent and have either-- (b)(4)(i) Graduated from a medical laboratory or clinical laboratory training program approved or accredited by ABHES, CAHEA, or other organization approved by HHS; or (b)(4)(ii) Successfully completed an official U.S. military medical laboratory procedures training course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); (b)(5)(i) Until September 1, 1997-- (b)(5)(i)(A) Have earned a high school diploma or equivalent; and (b)(5)(i)(B) Have documentation of training appropriate for the testing performed before analyzing patient specimens. Such training must ensure that the individual has-- (b)(5)(i)(B)(1) The skills required for proper specimen collection, including patient preparation, if applicable, labeling, handling, preservation or fixation, processing or preparation, transportation and storage of specimens; (b)(5)(i)(B)(2) The skills required for implementing all standard laboratory procedures; (b)(5)(i)(B)(3) The skills required for performing each test method and for proper instrument use; (b)(5)(i)(B)(4) The skills required for performing preventive maintenance, troubleshooting, and calibration procedures related to each test performed; (b)(5)(i)(B)(5) A working knowledge of reagent stability and storage; (b)(5)(i)(B)(6) The skills required to implement the quality control policies and procedures of the laboratory; (b)(5)(i)(B)(7) An awareness of the factors that influence test results; and (b)(5)(i)(B)(8) The skills required to assess and verify the validity of patient test results through the evaluation of quality control values before reporting patient test results; and (b)(5)(i)(B)(8)(ii) As of September 1, 1997, be qualified under 493.1489(b)(1), (b)(2), or (b)(4), except for those individuals qualified under paragraph (b)(5)(i) of this section who were performing high complexity testing on or before April 24, 1995; (b)(6) For blood gas analysis-- (b)(6) (i) Be qualified under 493.1489(b)(1), (b)(2), (b)(3), (b)(4), or (b)(5); (b)(6)(ii) Have earned a bachelor's degree in respiratory therapy or cardiovascular technology from an accredited institution; or (b)(6)(iii) Have earned an associate degree related to pulmonary function from an accredited institution; or (b)(7) For histopathology, meet the qualifications of 493.1449 (b) or (l) to perform tissue examinations. This STANDARD is not met as evidenced by: Based on a review of the Form CMS 209, review of education documents, a patient test report, and staff interview, testing person two did not meet the regulatory requirement for performing high-complexity testing (one of six testing personnel). The findings include: 1. A review of Form CMS 209 revealed that testing person number two was listed as a high-complexity testing person. 2. A review of education documents for testing person two revealed that person two did not qualify as a high- complexity testing person due to a lack of required science hours. 3. A review of patient medical record number 1C14532131 revealed grossing of a liver needle biopsy performed by testing person two. The test report date was 09/07/23. 3. An interview with the corporate Quality Assurance Operations Director on 05/14/2024 at 2:30 p.m. confirmed that testing person two grossed surgical tissues and did not have the required science hours to qualify as high-complexity testing personnel. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 23, 2022

Survey Type: Standard

Survey Event ID: E1RD11

Deficiency Tags: D5805 D5805

Summary:

Summary Statement of Deficiencies D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of final patient test reports, and interview with laboratory quality staff, the final patient test report failed to include the name and address of the laboratory where testing was performed for six of six final patient test reports for dates of services (DOS) ranging from 01/03/2022 to 05/16 /2022. The findings include: 1. Observation of the laboratory on 05/23/2022 at 8:30 am revealed an area where histopathology specimens are received, accessioned and grossed before being sent out for tissue processing, staining, and final interpretation. 2. Review of final patient test reports revealed the name and location of the laboratory where the grossing and final interpretation was performed was either not included or had the incorrect physical address on the final report for six of six reports reviewed. Reports where grossing was performed but not included are MRN: 1C14246835 - DOS 01/03/2022, MRN: 1C12799671 - DOS 02/14/2022, MRN: 1C12004199 - DOS 03/07/2022, MRN: 1C11405059 - DOS 04/13/2022, MRN: 1C12078505 - DOS 05/16 /2022); report with incorrect address is MRN: 10-225-087 - DOS 01/07/2022. 3. Interview with the two laboratory quality staff on 05/23/2022 at 12:45 pm confirmed the final patient test report failed to include the name and address of the laboratory where the testing was performed for six of six patient test reports in 2022. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --