Associates In Dermatology Care Dba

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 03D0666037
Address 11000 N Scottsdale Rd, Ste 120, Scottsdale, AZ, 85254
City Scottsdale
State AZ
Zip Code85254
Phone(480) 596-1110

Citation History (2 surveys)

Survey - January 16, 2025

Survey Type: Standard

Survey Event ID: FT8Y11

Deficiency Tags: D5473 D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on lack of cryostat and room temperature records from one testing date in October 2024 and interview with the facility personnel, the laboratory failed to monitor and document the temperature of the cryostat and the room temperature where dermatopathology reagents are utilized and stored on each day of patient testing. Findings include: 1. The laboratory processes specimens and interprets dermatopathology slides in conjunction with Mohs surgery, with an approximate annual test volume of 122. 2. The laboratory failed to monitor and document the temperature of the room where dermatopathology reagents are utilized on 10/18/2024. 3. The laboratory failed to monitor and document the temperature of the cryostat which is used to process patient specimens on 10/18/2024. 4. The laboratory tested 9 patients on 10/18/24. 5. The facility personnel interviewed on 1/16/2025 at 1:25 PM confirmed that the laboratory failed to monitor and document the room temperature of the laboratory and the temperature of the cryostat on 10/18/2024. D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (e)(2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. This STANDARD is not met as evidenced by: Based on lack of Quality Control (QC) documentation and interview with the facility personnel, the laboratory failed to document the acceptability of the Hematoxylin & Eosin (H&E) staining materials on 1 out of 3 testing dates reviewed during the survey, for intended reactivity and to ensure predictable staining characteristics. Findings include: 1. The laboratory performs Mohs under the subspecialty of Histopathology with a reported annual test volume of 122. 2. The laboratory failed to document the acceptability of the H&E stain on 1 out of 3 testing dates (10/18/2024) reviewed during the survey. 3. The laboratory tested 9 patient's specimens using the H&E stain on 10/18/24. 4. The facility personnel interviewed on 1/16/2025 at 1:20 PM confirmed the laboratory failed to document the H&E stain acceptability each day of use for intended reactivity and to ensure predictable staining characteristics on the testing date indicated above. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 27, 2018

Survey Type: Standard

Survey Event ID: 3VYE11

Deficiency Tags: D5293 D5791 D5787 D5805 D6094 D5891

Summary:

Summary Statement of Deficiencies D5293 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(b)(c) (b) The general laboratory systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access