Associates In Family Practice

CLIA Laboratory Citation Details

4
Total Citations
49
Total Deficiencyies
18
Unique D-Tags
CMS Certification Number 37D0471718
Address 210 Sw 89th, Oklahoma City, OK, 73139-8522
City Oklahoma City
State OK
Zip Code73139-8522
Phone405 631-1116
Lab DirectorMARVIN RODGERS

Citation History (4 surveys)

Survey - May 15, 2025

Survey Type: Standard

Survey Event ID: DCW611

Deficiency Tags: D0000 D1001 D5211 D6018 D5211 D5413 D5469 D5413 D5469 D6018

Summary:

Summary Statement of Deficiencies D0000 The recertification survey was performed on 05/15/2025. The laboratory was found in compliance with standard-level deficiencies cited. The findings were reviewed with the testing person at the conclusion of the survey. D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: Based on a review of manufacturer's instructions, observation, and interview with the testing person, the laboratory failed to follow the manufacturer's instructions for expiration dates for four of four waived testing materials. Findings include: I. LIQUID URINE CONTROLS (1) On 05/15/2025 at 09:45 am, observation of the laboratory refrigerator contents identified the following expired materials which appeared to be available for use: (a) One bottle of Consult Diagnostics Liquid urine control Level 1, lot #230321022, manufacturer's expiration date 03/20/2025; (b) One bottle of Consult Diagnostics Liquid urine control Level 2, lot #230316019, manufacturer's expiration date 03/15/2025. (2) The findings were reviewed with the testing person, who stated on 05/15/2025 at 10:00 am the test materials had expired and were available for use. II. HEMOGLOBIN A1C CONTROLS (1) On 05/15/2025 at 09:45 am, an observation of the laboratory refrigerator contents on 05/15/2025 at 09:30 am, identified the following: (a) One bottle of Affinion HbA1c level 1 Control, lot #92964408, with an opened date of 02/13/2025; (b) One bottle of Affinion HbA1c level 2 Control, lot #72964410, with an opened date of 02/13/2025. (2) A review of the manufacturer's package inserts for the QC materials under the heading "Open control vials" stated, "Opened controls vials are stable for 60 days when stored refrigerated 2-8 degree Centigrade (36-46 degrees Fahrenheit." (3) The findings were discussed with the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- testing person who stated on 05/15/2025 at 09:50 am, the expired HbA1c controls were available for use beyond the modified expiration date. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to review and evaluate proficiency testing results for one of four Hematology Proficiency testing events reviewed in 2024 and 2025. Findings include: (1) A review of Hematology Proficiency testing records for four events (First 2024, Second 2024, Third 2024, and First 2025) identified the following failure with no evidence that a

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 30, 2023

Survey Type: Standard

Survey Event ID: TQH711

Deficiency Tags: D5417 D5421 D5429 D5441 D5469 D5807 D5469 D5807 D0000 D5311 D5417 D5421 D5429 D5441

Summary:

Summary Statement of Deficiencies D0000 The recertification survey was performed on 08/30/2023. The laboratory was found in compliance with standard-level deficiencies cited. The findings were reviewed with the testing person at the conclusion of the survey. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: Based on observation, review of written policy, and interview with the testing person, the laboratory failed to follow it's policy to ensure positive identification for ten of 19 patients for CBC testing on the Medonic M analyzer. Findings include: (1) On 08/30 /2023 at 11:15 am, the testing person stated CBC testing was performed in the laboratory on the Medonic M analyzer; (2) On 08/30/2023 at 11:15 am, observation of the Hematology area of the laboratory identified ten of 19 tubes labeled with a first initial and last name; (3) A review of policy identified the following: (a) The policy titled, "Blood Specimen Collection using Venipuncture" stated " All blood tubes should be labeled with the patient's full name or other unique identifier"; (4) Interview with the testing person on 08/30/2023 at 11:15 am confirmed 10 of 19 EDTA tubes were not labeled according to the laboratory policy. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to ensure control materials were not used beyond the expiration date for one of six lot numbers reviewed. Findings include: (1) On 08/30/2023 at 09:25 am, the testing person stated the following: (a) The laboratory performed CBC (Complete Blood Count) testing using the Medonic M-Series analyzer; (b) Three levels of QC (quality control) materials were tested each day of patient testing. (2) A review of QC records for six lot numbers of QC materials used from 06/13/2023 through the day of the survey identified a control material had been used beyond the manufacturer's expiration date for one of nine lot numbers reviewed as follows: (a) High control lot #22302-33 - Used from 06/13/2023 through 07/17/2023; the manufacturer's expiration date was 07/14/2023. (3) The records showed a patient CBC had been reported on 07 /17/2023 when the laboratory had used expired level three QC material to assess the acceptable performance of the analyzer; (4) The findings were reviewed with the testing person who stated on 08/30/2023 at 12:20 pm, the control had been used beyond the expiration date. 48517 Based on observation and interview with testing person #1, the laboratory failed to ensure expired supplies were not available for use. Findings include: (1) Observation of the storage room 08/30/2023 at 09:30 am, identified the following expired collection tubes that appeared to be available for use: (a) 12 Vacuette K2EDTA tubes - lot #454209 with an expiration date of 07/01/2023. (2) Interview with testing person #1 08/30/2023 at 09:30 am confirmed the Vacuette K2EDTA tubes were available for use. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to ensure the reportable range had been utilized for one of four analytes reviewed. Findings include: (1) On 08/30/2023 at 10:45 am, the testing person stated, a new Medonic M-Series hematology analyzer was put into use to perform patient CBC (Complete Blood Count) testing in November of 2021; (2) A review of performance specification records identified the reportable range had been demonstrated as follows: (a) Platelet - 9-892(x10^9/L) (3) A review of the manufacturer's document titled, "QuestQuanum" under the section 11.3 titled, "Parameter Ranges" defined the reportable range as follows: (a) Platelet - 30-1800 (x10^9/L) (4) Interview with the testing person on 08/30/2023 at 10:45 am, confirmed the laboratory was using the manufacturer's reportable ranges instead of the reportable range that had been demonstrated by the laboratory. -- 2 of 5 -- D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on a review of records, manufacturer's instructions, and interview with the testing person, the laboratory failed to ensure the manufacturer's instructions were followed for performing maintenance procedures during the review period of June 2022 through June 2023. Findings include: (1) On 08/30/2023 at 11:15 am, the testing person stated CBC (Complete Blood Count) testing was performed using the Medonic M analyzer; (2) A review of the manufacturer's maintenance log showed the following required monthly maintenance procedures: (a) "Monthly Cleaning (Hypochlorite)" (b) "Clot Prevention (enzymatic)" (3) A review of maintenance logs from June 2022 through June 2023 identified no documentation monthly maintenance had been performed between: (a) 06/27/2022 and 08/30/2022 (b) 09/30/2022 and 11/18/2022 (c) 12/28/2022 and 03/01/2023 (d) 04/28/2023 and 07/18/2023 (e) 03/17/2023 and 04 /03/2023 (4) The records were reviewed with the testing person who stated on 08/30 /2023 at 11:15 am, monthly maintenance had not been documented as performed as shown above. D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to have control procedures that monitored the accuracy and precision of the complete analytic process for nine of nine months reviewed for testing performed using the Medonic M-series Hematology analyzer. Findings include: (1) On 08/30 /2023 at 09:25 am, the testing person stated the following: (a) The laboratory performed CBC (Complete Blood Count) testing using the Medonic M-Series analyzer; (b) Three levels of QC (quality control) materials were tested each day of patient testing. (2) A review of records from November 2022 through July 2023 identified no evidence, such as Levey-Jennings graphs and cumulative statistical data, to prove that QC results had been monitored for variances (i.e.,biases, shifts, trends); (3) Interview with the testing person on 08/30/2023 at 11:35 am confirmed that QC data to include Levey-Jennings graphs and cumulative statistical data had not been printed and reviewed during the review period. -- 3 of 5 -- D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to verify the stated value of control materials before they were put into use for six of six lot numbers. Findings include: (1) On 08/30/2023 at 09:25 am, the testing person stated the following: (a) The laboratory performed CBC (Complete Blood Count) testing using the Medonic M-Series analyzer; (b) Three levels of QC (quality control) materials were tested each day of patient testing. (c) The manufacturer's provided ranges were used to determine acceptability of quality control results. (2) A review of records for six control lot numbers identified no evidence the provided ranges were verified before the lot numbers were put into use for six of six lot numbers as follows: (a) Low control lot #22302-31, Normal control lot #22302-32, and High control lot #22305-33 used from 06/13/2023 through 07/17/2023; (b) Low control lot #22304-31, Normal control lot #22304-32, and High control lot #22304-33 put into use on 07/18/2023 and currently in use. (3) The findings were reviewed with the testing person who stated on 08/30/2023 at 12:15 pm the manufacturer's ranges had not been verified before the above lot numbers had been put into use. D5807 TEST REPORT CFR(s): 493.1291(d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to ensure reference intervals were determined as appropriate for the laboratory's patient population for two of two patient reports reviewed. Findings include: (1) On 08 /30/2023 at 10:50 am, the testing person stated the laboratory began using the Medonic M-Series hematology analyzer starting in November of 2021 to perform patient CBC (Complete Blood Count) testing; (2) On 08/30/2023 two patient CBC reports were reviewed - the first report was for an adult male patient with the testing performed on 04/28/2023; the second report was for an adult female patient with the testing performed on 04/03/2023. Both reports included the same reference intervals for the following CBC parameters: (a) RBC (red blood cell) count - 3.5-5.5(x10^12); -- 4 of 5 -- (b) Hemoglobin - 11.5-16.5 g/dL; (c) Hematocrit - 35-55%. (3) The reports were reviewed with the testing person who stated on 08/30/2023 at 11:23 am, the patient reports did not include gender specific reference ranges for RBC, Hemoglobin, and Hematocrit. -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 26, 2021

Survey Type: Standard

Survey Event ID: OQ3P11

Deficiency Tags: D0000 D3031 D5211 D5215 D3031 D5211 D5215 D5413 D5413

Summary:

Summary Statement of Deficiencies D0000 The recertification survey was performed on 08/26/2021. The findings were reviewed with testing person #1 at the conclusion of the survey. The laboratory was found in compliance with standard-level deficiencies cited. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on a review of records and interview with testing person #1, the laboratory failed to retain records for at least 2 years for 1 of 18 months. Findings include: (1) On 08/26/2021 at 10:20 am, testing person #1 stated the following to the surveyor: (a) Routine CBC (Complete Blood Count) testing was performed on the Beckman Coulter AcT Diff 2 analyzer; (b) Three levels of Coulter 4C-ES QC (quality control) materials were stored in the laboratory refrigerator; (2) The surveyor reviewed laboratory refrigerator temperatures from January 2020 through June 2021 with the following identified: (a) Records between 10/31/2020 and 12/02/2020 were not available (3) The surveyor asked testing person #1 if the records between 10/31/2020 and 12/02/2020 could be located; (4) Testing person #1 stated on 08/26/2021 at 02:10 pm the records between 10/31/2020 and 12/02/2020 for the laboratory refrigerator could not be located. The surveyor could not determine if the temperatures had been monitored for 1 of 18 months. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on a review of records and interview with testing person #1, the laboratory failed to review and evaluate proficiency testing results for 2 of 10 events. Findings include: FAILURES (1) On 08/26/2021, the surveyor reviewed 2019, 2020, and 2021 proficiency testing records and identified the following failures: (a) Third 2020 Hematology Event (FH2-C) (i) Blood Cell Identification - The laboratory failed the results for 1 of 5 samples (BCP-23); (2) The surveyor could not locate evidence in the records proving the failure had been addressed; (3) The surveyor reviewed the records with testing person #1, and asked if

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 11, 2019

Survey Type: Standard

Survey Event ID: GSDF11

Deficiency Tags: D0000 D2015 D2015 D5211 D5403 D5417 D5435 D6054 D0000 D5211 D5403 D5417 D5435 D6018 D6018 D6054

Summary:

Summary Statement of Deficiencies D0000 The recertification survey was performed on 06/11/19. The laboratory was found in compliance with standard-level deficiencies cited. The findings were reviewed with the testing person at the conclusion of the survey. D2015 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(5)(6) (5) The laboratory must document the handling, preparation, processing, examination, and each step in the testing and reporting of results for all proficiency testing samples. The laboratory must maintain a copy of all records, including a copy of the proficiency testing program report forms used by the laboratory to record proficiency testing results including the attestation statement provided by the PT program, signed by the analyst and the laboratory director, documenting that proficiency testing samples were tested in the same manner as patient specimens, for a minimum of two years from the date of the proficiency testing event. (6) PT is required for only the test system, assay, or examination used as the primary method for patient testing during the PT event. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory director and/or testing person failed to sign proficiency testing attestation statements. Findings include: (1) During the survey, the surveyor reviewed 2018 and 2019 proficiency testing records and identified the following for 2 of 7 events: (a) FH2-B 2018 Hematology Event - The attestation statement had not been signed by the laboratory director and testing person; (b) CM-A 2019 Clinical Microscopy Event - The attestation statement had not been signed by the laboratory director. (2) The surveyor reviewed the findings with the testing person who stated the attestations had not been signed as indicated above. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on a review of records and interview with the testing person, the laboratory failed to review and evaluate proficiency testing results. Findings include: (1) During the survey, the surveyor reviewed 2018 and 2019 proficiency testing records and identified the following failures and biases (the biases were identified using the SDI (Standard Deviation Index) values assigned by the proficiency program): (a) Second 2018 Clinical Microscopy Event (CM-B) (i) Urine Sediment ID - The laboratory failed the result for 1 of 3 samples (USP-06). (b) Second 2018 Hematology Event (FH2-B) (i) MCV (Mean Corpuscular Volume) - The laboratory failed the results for 3 of 5 samples. In addition, 5 of 5 results exhibited a positive bias: (aa) FH2-11 - SDI of 3.1 (bb) FH2-12 - SDI of 2.3 (cc) FH2-13 - SDI of 3.7 (this resulted in a failure) (dd) FH2-14 - SDI of 3.2 (this resulted in a failure) (ee) FH2-15 - SDI of 3.8 (this resulted in a failure) (2) The records were then reviewed further by the surveyor. There was no evidence

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access