Associates In Pediatrics

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 14D0415159
Address 1020 Schaumburg Rd, Streamwood, IL, 60107
City Streamwood
State IL
Zip Code60107
Phone(847) 742-6888

Citation History (1 survey)

Survey - February 13, 2019

Survey Type: Standard

Survey Event ID: HU5211

Deficiency Tags: D5301 D5791

Summary:

Summary Statement of Deficiencies D5301 TEST REQUEST CFR(s): 493.1241(a) The laboratory must have a written or electronic request for patient testing from an authorized person. This STANDARD is not met as evidenced by: Based on review of the laboratory's procedures manual and laboratory records and interview with testing personnel; the laboratory failed to have a written or electronic request for patient testing. Findings include: 1. Review of the laboratory's policies and procedures revealed that orders for testing are documented in the patients' electronic medical records. 2. At 11:00 AM on February 13, 2019 the surveyor selected a total of 7 patient's names from the laboratory's patient testing log. One of 7 patients did not have a request for Complete Blood Count testing dated 11/26/2018. However, there was documentation on the testing log which reads as follows: "not enough blood collected results abnormal." 3. Review of the corresponding patient's test records revealed that no results were reported for the patient whose results were documented as "not enough blood collected results abnormal" on 11/26/2018. 4. At 12:30 PM on February 13, 2019, testing personnel confirmed the surveyor's findings. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Based on review of the laboratory's policies, procedures manual, laboratory records, patients' test records and interview with testing personnel; the laboratory failed to establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and correct problems identified in the analytic systems specified in 493.1251 through 493.1283. Findings include: 1. There were no written procedures that describes the laboratory's process for assessing (monitoring) analytic systems and documenting its activities. 2. Review of testing logs show that, on 11/26/2018, the laboratory documented a patients Complete Blood Count (CBC) with the following notation: "not enough blood collected results abnormal." 3. Review of the corresponding patient's test record shows that on 11/26/2018 there was no documentation to show that a CBC test was ordered, nor documentation to show that a CBC test result was reported. 4. There was no documentation to show

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access