Bay Area Advance Gastroenterology Care Inc

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 10D2277803
Address 1130 Kyle Wood Lane, Brandon, FL, 33511
City Brandon
State FL
Zip Code33511
Phone813 600-5423
Lab DirectorARCHI PATEL

Citation History (1 survey)

Survey - March 18, 2026

Survey Type: Standard

Survey Event ID: B0GF11

Deficiency Tags: D6102 D0000

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Bay Area Advanced Gastroenterology Care Inc on 3/18/2026. The laboratory was surveyed under 42 CFR Part 493 CLIA requirements. Standard deficiencies cited are as follows: D6102 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(12) (e)(12) Ensure that prior to testing patients specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results; This STANDARD is not met as evidenced by: Based on record reviews and interview, the Laboratory Director failed to ensure that prior to testing patients' specimens, two of two Testing Personnel (TP-A and TP-B) received the appropriate training and had demonstrated that they could perform all testing operations for Histopathology. Findings included: 1. The CMS-209 Laboratory Personnel Report (CLIA) signed and dated by the Laboratory Director on 3/16/26 listed two Testing Personnel (TP-A and TP--B) who currently perform Histology testing at the laboratory. The The CMS-209 Laboratory Personnel Report (CLIA) signed and dated by the Laboratory Director on 2/12/24 for the prior survey did not list TP-A or TP-B. 2. The date of hire (DOH) for this laboratory, training records, and evaluation of competencies for TP-A and TP-B were requested for review. The Quality Assurance (QA) Coordinator stated on 3/18/26 at 12:05 p.m., both had worked for the parent company for a long time and could not provide a definite date from 2/12/24 to 3/18/26 for the DOHs and there were no training records or evaluation of competencies for this laboratory prior to performing patient testing at this laboratory. 3. The policy for Medical Director (Laboratory Director) Qualifications and Duties last approved by the Laboratory Director on 5/5/25 listed one of the duties as ensuring staff could demonstrate competencies and receive Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- appropriate training. 4. The procedure for Pathologist Professional Competency (Testing Personnel) signed and dated by the Laboratory Director on 5/5/25 listed the frequency of evaluation as six months and annually there after. There was no indication there was an approved policy that required training and evaluation of competencies prior to performing patient testing. 5. The Laboratory Director confirmed via phone on 3/18/26 at 12:35 p.m. both TP-A and TP-B had worked for the parent company for a long time and could not provide a definite date from 2/12/24 to 3/18/26 for the DOHs and there were no training records or evaluation of competencies for this laboratory prior to performing patient testing at this laboratory. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access