CMS Certification Number 21D1017002
Address 606 Dutchman'S Lane, Easton, MD, 21601
City Easton
State MD
Zip Code21601
Phone(410) 763-8272

Citation History (1 survey)

Survey - June 25, 2019

Survey Type: Standard

Survey Event ID: 0W8611

Deficiency Tags: D6046 D5445

Summary:

Summary Statement of Deficiencies D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the 2018 and 2019 records showing receipt of the selective strep test media (SSA media) into the laboratory (lab) and interview with the technical consultant on the day of survey, the lab did not document all quality control procedures performed when recording the receipt of the SSA media into the laboratory for patient testing. Findings: 1. The lab receives already prepared selective strep agar for patient throat culture testing; 2. The lab documents (on a log) the receipt and condition of the agar delivered to the lab; and 3. In 2018 and 2019 the person receiving the agar and observing acceptability for use, did not initial these activities on the log to show who performed the checks of the agar when received by the lab. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on interview with the technical consultant (TC) on the day of survey, the TC did not document competency assessments made for testing personnel who performed Group A strep testing using selective strep agar and taxo A disks (group A strep testing). Findings: 1. The physicians interpret the results of the Group A strep testing; 2. The technical consultant monitors the proficiency testing results, quality control (media check log) records and patient test records; and 3. The annual competency review showing that the activities were performed, is not documented for each physician interpreting the results of the Group A strep testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access