Bay Ridge Medical Group Pllc

CLIA Laboratory Citation Details

2
Total Citations
15
Total Deficiencyies
10
Unique D-Tags
CMS Certification Number 33D2304226
Address 7404 5th Ave, Ste 1, Brooklyn, NY, 11209
City Brooklyn
State NY
Zip Code11209
Phone929 415-8856
Lab DirectorJOHN LEE

Citation History (2 surveys)

Survey - January 28, 2026

Survey Type: Standard

Survey Event ID: FNTF11

Deficiency Tags: D5209 D5439 D6000 D5413 D5445 D6020

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of Standard Operating Procedures (SOP), personnel training records, competency evaluation documentation, as well as interview with the Laboratory Personnel (LP), the laboratory failed to establish and follow written policies and procedures to assess employee competency. FINDINGS: 1. The current, approved Bay Ridge Medical Group, PLLC SOPs did not include a written training, competency evaluation policy comprising of the following guidelines for Testing Personnel (TP): a. Direct observations of routine patient test performance, specimen preparation, processing, and testing. b. Monitoring the recording and reporting of test results. c. Review of intermediate test results or worksheets, quality control records, Proficiency Testing (PT) results, and preventive maintenance records. d. Direct observations of instrument maintenance performance and function checks. e. Assessment of patient test performance through testing previously analyzed specimens, internal blind testing samples, or external proficiency testing samples. f. Assessment of problem-solving skills. 2. There was no documentation of TP initial training, six-month, and annual competency evaluations. 3. The LP confirmed the findings on January 28, 2026, at 11:30 A.M. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of SOPs, analyzer manufacturer's instructions, lack of temperature and humidity records, as well as interview with the TP, the laboratory failed to monitor and document temperature and humidity in the area where patient specimen testing and test kit storage occurred. FINDINGS: 1. There was no documentation of refrigerator, room temperature, and humidity in the area where patient specimen testing and test kit storage occurred. 2. The i-Stat manufacturer's instructions specified analyzer operating temperature range of 16-30C (61-86F). 3. There was no documentation of temperature monitoring for the refrigerator utilized for storage of i- Stat test cartridges. 4. The i-Stat manufacturer's instructions specified test kit storage temperature between 2-8C (35-46F). 5. Approximately nine patients were tested in 2025. 6. The current, approved Bay Ridge Medical Group, PLLC SOPs did not include instructions for monitoring and documenting refrigerator, room temperature and humidity in the area where patient specimen testing and test kit storage occurred. 7. The TP confirmed the findings on January 28, 2026, at 11:30 A.M. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3)-- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on review of SOPs, analyzer manufacturer's instructions, lack of calibration verification records, as well as interview with TP, the laboratory failed to perform and document calibration verification procedures following the manufacturer's calibration verification instructions. FINDINGS: 1. There was no documentation of PT/INR, ACT, and Chem 8+ calibration verification. 2. This is contrary to instructions indicated in the current, approved Bay Ridge Medical Group, PLLC SOP and PT /INR, ACT, and Chem 8+ analyzer manufacturer's instructions which specify -- 2 of 4 -- calibration verification performance twice a year. 3. Approximately nine patients were tested in 2025. 4. The TP confirmed the findings on January 28, 2026, at 11:30 A.M. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) (d) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493. 1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (d)(3) At least once each day patient specimens are assayed or examined perform the following for: This STANDARD is not met as evidenced by: Based on review of SOPs, analyzer manufacturer's instructions, lack of test system control records, as well as interview with TP, the laboratory failed to perform and document control procedures using the number and frequency specified by the manufacturer. FINDINGS: 1. There was no documentation of PT/INR, ACT, and Chem 8+ Quality Control (QC) performance for each new lot or shipment. 2. This is contrary to instructions indicated in the current, approved Bay Ridge Medical Group, PLLC SOP and PT/INR, ACT, and Chem 8+ analyzer manufacturer's instructions which specify QC performance for each new lot or shipment. 3. Approximately nine patients were tested in 2025. 4. The TP confirmed the findings on January 28, 2026, at 11:30 A.M. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of SOPs, personnel training and competency records, lack of Quality Assurance (QA) policies, as well as interview with the TP, the LD failed to provide overall management and direction of the laboratory services. FINDINGS: The LD failed to: 1. Draft, approve QA policies for all phases of moderate complexity testing. Refer to D6020. 2. Perform and document TP training and competency evaluations. Refer to D5209. 3. The TP confirmed the findings on January 28, 2026, at 11:30 A.M. D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) (e)(5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; -- 3 of 4 -- This STANDARD is not met as evidenced by: Based on review of SOPs, lack of QA policies, as well as interview with the LP, the LD failed to ensure that the QC and QA programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. FINDINGS: 1. The current, approved Bay Ridge Medical Group, PLLC SOPs did not include QA policies for all phases of the general laboratory system. 2. The TP confirmed the findings on January 28, 2026, at 11:30 A.M. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 16, 2025

Survey Type: Special

Survey Event ID: FSVQ11

Deficiency Tags: D2130 D2016 D2130 D6000 D6016 D2016 D0000 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 Based on a proficiency testing (PT) desk review survey performed on January 16, 2025, the laboratory was found to be out of compliance based on the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 C.F.R. 493.803 Condition: Successful participation. D6000 - 42 C.F.R. 493.1403 Condition: Laboratory Director, moderate complexity. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Centers for Medicare & Medicaid Services (CMS) Proficiency Testing (PT) Certification and Survey Provider Enhanced Reporting system (CASPER 0155D) and American Proficiency Institute (API) PT summary reports, the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- laboratory failed to successfully participate in the CMS approved PT program for two out of three consecutive testing events in the Hematology specialty for the Cell Identification or White Blood Cell Differential (Cell ID or WBC Diff), Red Blood Cell (RBC), Hematocrit (HCT) (Non-Waived), Hemoglobin (HGB) (Non-Waived), and Platelets test analytes in 2024 resulting in unsuccessful performance. Refer to D2130. D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on CMS PT CASPER 0155D and API PT summary reports from 2024, the laboratory failed to achieve satisfactory performance (80% or greater) for two out of three consecutive testing events in the Hematology specialty for the Cell ID or WBC Diff, RBC, HCT (Non-Waived), HGB (Non-Waived), and Platelets test analytes. FINDINGS: 1. A review of the CASPER 155 report revealed the following unsatisfactory scores: Hematology Specialty: 2024 Second Event = 0% 2024 Third Event = 60% Cell ID or WBC Diff Test Analyte: 2024 Second Event = 0% 2024 Third Event = 60% RBC Test Analyte: 2024 Second Event = 0% 2024 Third Event = 60% HCT (Non-Waived) Test Analyte: 2024 Second Event = 0% 2024 Third Event = 60% HGB (Non-Waived) Test Analyte: 2024 Second Event = 0% 2024 Third Event = 60% Platelets Test Analyte: 2024 Second Event = 0% 2024 Third Event = 40% 2. A review of the proficiency testing scores from API (2024) confirmed the above findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of CMS PT CASPER 0155D and API PT summary reports from 2024, the laboratory director (LD) failed to provide overall management and direction of the laboratory services. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of CMS PT CASPER 0155D and API PT 2024-2 and 2024-3 summary reports, the LD failed to ensure successful participation in an HHS approved proficiency testing program. Refer to D2130. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access