Baylor College Of Medicine

CLIA Laboratory Citation Details

3
Total Citations
25
Total Deficiencyies
11
Unique D-Tags
CMS Certification Number 45D2041010
Address 333 N Texas Avenue, Webster, TX, 77598
City Webster
State TX
Zip Code77598
Phone(713) 798-4951

Citation History (3 surveys)

Survey - March 5, 2024

Survey Type: Standard

Survey Event ID: B1UD11

Deficiency Tags: D0000 D5473 D6102 D6127 D6128 D0000 D5473 D6102 D6127 D6128

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative(s) at the exit conference. The facility was found to be in compliance with applicable Conditions in the CLIA program, and recertification is recommended. D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on the direct observation of the surveyor and confirmed in an interview, the laboratory failed to have QC slides for Hematoxylin and Eosin (H&E) stain to predict stain characteristics prior to patient testing for 5 of 5 days H&E stain was in use in 2023. The findings were: 1. The surveyor's direct observation on 03/05/2024 at 10:35 am in the laboratory revealed no H&E QC slides for 5 of 5 days H&E was in use. 02 /16/2023 08/18/2023 09/15/2023 10/20/2023 12/01/2023 2. In an interview on 03/05 /2024 at 10:39 am in the laboratory, the laboratory director confirmed the above findings. Key: QC=Quality Control D6102 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(12) The laboratory director must ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- results. This STANDARD is not met as evidenced by: Based on the review of the laboratory's CMS 209 form, policy, personnel competency assessment records, and confirmed in an interview, the laboratory director failed to ensure personnel competency assessment was documented prior to working independently. (Refer to D6127 and D6128). D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on the review of the laboratory's CMS 209 form, policy, personnel competency assessment records, and confirmed in an interview, the technical supervisor failed to document 1 of 4 initial competency assessment and 3 of 4 semiannually competency assessment prior to work independently. The findings were: 1. Review of the laboratory's CMS 209 form titled Laboratory Personnel Report (CLIA), signed by the laboratory director on 03/05/2024, revealed 5 testing personnel (TP) and the laboratory director is also the technical supervisor. 2. Review the laboratory's policy titled PROFESSIONAL COMPETENCY under POSSIBLE CRITERIA CATEGORIES FOR THE ASSESSMENT revealed "...5. Grossing competency and /or..." and under ASSESSMENT PROCEDURE revealed "1. Assessment is by the Medical Director is done initially during pathologist's first 6 month then annual thereafter." In addition, under DOCUMENTATION revealed "the Medical Director will document assessment criteria on annual professional competency summary form." 3. Review of the personnel competency records revealed the technical supervisor failed to document 1 of 4 initial competency assessment and 3 of 4 initial and semiannually competency assessment during the first year prior to work independently. Missing initial competency assessment TP#3 Hired Date: 05/28/2023 Missing initial and semiannual competency assessment during the first year TP#1 Hired Date: 02/17/2022 TP#2 Hired Date: 02/29/2008 TP#5 Hired Date: 07/21/2022 4. In an interview on 03/05/2024 at 10:25 am in the laboratory, the laboratory director confirmed the above findings. Key: CMS=Center of Medicare and Medicaid Services D6128 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least annually after the first year, unless test methodology or instrumentation changes, in which case, prior to reporting patient test results, the individual's performance must be reevaluated to include the use of the new test methodology or instrumentation. This STANDARD is not met as evidenced by: Based on the review of the laboratory's CMS 209 form, policy, personnel competency assessment records, and confirmed in an interview, the technical supervisor failed to -- 2 of 3 -- document 2 of 4 annual competency assessment. The findings were: 1. Review of the laboratory's CMS 209 form titled Laboratory Personnel Report (CLIA), signed by the laboratory director on 03/05/2024, revealed 5 testing personnel (TP) and the laboratory director is also the technical supervisor. 2. Review the laboratory's policy titled PROFESSIONAL COMPETENCY under DOCUMENTATION revealed "the Medical Director will document assessment criteria on annual professional competency summary form." 3. Review of the personnel competency records revealed the technical supervisor failed to document 2 of 4 annual competency assessment prior to work independently. TP#1 Hired Date: 02/17/2022 TP#2 Hired Date: 02/29 /2008 4. In an interview on 03/05/2024 at 10:25 am in the laboratory, the laboratory director confirmed the above findings. Key: CMS=Center of Medicare and Medicaid Services -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 9, 2022

Survey Type: Standard

Survey Event ID: NBYD11

Deficiency Tags: D0000 D5217 D5217

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative(s) at the exit conference. The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. . D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on the review of the laboratory's policy, the laboratory's twice annual accuracy check records, CMS 116 form, and confirmed in an interview found the laboratory failed to have documentation of evaluating and verifying the accuracy of the test results for 1 of 2 events in 2021 for 1 of 1 non-regulated analyte: surgical frozen section. The findings were: 1. Review of the laboratory's policy revealed no policy for evaluation and verification of the accuracy of test results twice annually for surgical frozen section. 2. Review of the laboratory's twice annual accuracy check records for surgical frozen section revealed the laboratory failed to perform 1 of 2 accuracy check events in 2021. 3. Review of CMS 116 form signed by LD on 3/8/2022 revealed the annual volume of frozen section was 6. 4. An interview with Assistant laboratory manager on 3/9/22 at 11:15 am in the lab confirmed the above findings. Key: CMS=Centers of Medicare and Medicaid Services LD=Laboratory Director . Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 10, 2020

Survey Type: Standard

Survey Event ID: LC9Q11

Deficiency Tags: D0000 D0000 D5407 D5413 D5433 D5781 D5407 D5413 D5433 D5781 D5791 D5791

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative at the entrance and exit conferences. The facility representative was given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. Note: The CMS-2567 (Statement of Deficiencies) is an official, legal document. All information must remain unchanged except for entering the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility