Berkley Hills Lab

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 39D0946050
Address 322 Warren Street, Johnstown, PA, 15905
City Johnstown
State PA
Zip Code15905
Phone(814) 288-4498

Citation History (2 surveys)

Survey - January 11, 2022

Survey Type: Standard

Survey Event ID: YD8Z11

Deficiency Tags: D2094 D2094

Summary:

Summary Statement of Deficiencies D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on personnel interview of the Laboratory Supervisor and review of proficiency records, the laboratory failed to attain a satisfactory score for the following analytes in the American Academy of Family Physicians (AAFP) 3rd event of 2021. findings include: 1. PSA 50% 2. Vitamin B-12 50% 3. Urine Microalbumin 0% During the survey (16:30 01/11/2022), the Laboratory Supervisor confirmed the above findings. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 10, 2019

Survey Type: Standard

Survey Event ID: ZKMR11

Deficiency Tags: D5439 D6046 D6031 D6046 D5439 D6031

Summary:

Summary Statement of Deficiencies D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on review of calibration verification documentation and interview with testing personnel (TP) #1, the laboratory failed to perform calibration verification on 1 of 1 Abbott Architect i1000 and 1 of 1 Beckman Coulter AU480 used to perform chemistry and endocrinology tests at least once every 6 months from 2018 to the date of survey. Finding Include: 1. On the day of survey, 9/10/2019, the laboratory failed to perform calibration verification on 1 of 1 Abbott Architect i1000 and 1 of 1 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Beckman Coulter AU480 used to perform chemistry and endocrinology tests at least once every 6 months in 2018 and 2019. 2. Calibration Verification was performed on the Abbott Architect i1000 on: - 03/23/2018 - 08/28/2019 3. Calibration Verification was performed on the Beckman Coulter AU480 on: - Not performed in 2018 - 08/28 /2019 4. In 2018: 77,181 patient tests were analyzed on the Beckman Coulter AU480 chemistry analyzer. 5. In 2019: 59,118 patient tests were analyzed on the Beckman Coulter AU480 chemistry analyzer. 6. In 2018: 5,640 patient tests were analyzed on the Abbott Architect i1000 chemistry analyzer. 7. In 2019: 4,004 patient tests were analyzed on the Abbott Architect i1000 chemistry analyzer. 8. TP#1 confirmed the findings above on 9/10/2019 around 10:10 am. D6031 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(13) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(13) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; This STANDARD is not met as evidenced by: Based on review of laboratory procedures, and interview with the testing personnel (TP) #1, the laboratory director failed to ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process from 2017 to the date of survey. Findings Include: 1. On the date of survey, 9/10/2019, the laboratory could not provide the following procedures: - Quality Assurance /Assessment Policy. - Competency Assessment Policy. 2. The following analyzer polices did not include measures for quality control: - Beckman Coulter AU480 analyzer used to perform Routine Chemistry testing. - Sysmex i1000 XS analyzer used to perform Complete Blood Count testing. - Abbott Architect i1000 analyzer used to perform Endocrinology testing. 3. The following polices were not signed by the LD: - Revised Serum Pregnancy Procedure. - Revised Erythrocyte Sedimentation Rate procedure (ESR). 4. TP#1 confirmed the findings above on 9/10/2019 around 10: 00 am. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on review of testing personnel competency assessment records, review of the competency assessment policy and interview with TP #1, the technical consultant (TC) failed to evaluate the competency of 1 of 5 TP performing Hematology, chemistry and Immunology testing in 2019. Findings Include: 1. On the day of survey, 9/10/2019, the laboratory could not provide competency assessment documentation for 1 of 5 TP (TP# 4). All TP were assessed for competency on January of 2019. 2. TP#1 confirmed the finding above on 9/10/2019 around 9:40 am. -- 2 of 2 --