Beverly & Brewer Md Pc

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 11D0266265
Address 900 Gordon Ave, Thomasville, GA, 31792
City Thomasville
State GA
Zip Code31792
Phone(229) 226-1200

Citation History (1 survey)

Survey - May 16, 2018

Survey Type: Standard

Survey Event ID: Q76O11

Deficiency Tags: D0000 D5439

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on May 16, 2018. The laboratory was not in compliance with all applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on document review and staff interview, the laboratory failed to calibrate the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Beckman Coulter AcT diff 2 Hematology analyzer every 6 months. Findings: 1. Review of the Beckman Coulter AcT diff 2 hematology analyzer installation documents showed that the analyzer was calibrated in January 2017 as part of the install. The analyzer had not been calibrated since January 2017. Review of service documents for the analyzer did not indicate that the analyzer had been calibrated due to service requirements. 2. Interview with staff #2 (CMS form 209) on May 16, 2018 in the laboratory, confirmed that the Beckman Coulter AcT diff 2 hematology analyzer had not been calibrated since January 2017 as part of the installation. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access