Citation History (2 surveys)

Survey - April 24, 2026

Survey Type: Standard

Survey Event ID: L1IV11

Deficiency Tags: D5401

Summary:

Summary Statement of Deficiencies D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) (a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on review of instrument records, donor records, and the procedure and interview with the quality management representative (QMR), the laboratory failed to follow procedure and update the instrument identification number in the Donor Information System (DIS) when the instrument was placed out of service. Findings: 1. The laboratory used two software databases: 1) the Calibration Maintenance System (CMS) which stored maintenance records for the digital refractometers used to test for total protein and 2) the DIS which stored information for each plasma donor and donation. 2. Each digital refractometer was assigned an equipment identification number. 3. Plasma donors were processed through donor screening stations which had designated computer numbers. 4. Each donor screening station was assigned a digital refractometer which was linked to the computer number for that screening station. 5. The digital refractometer used to test each donor could be identified based on the computer number of the screening station the donor was processed through. 6. The DIS showed that patient B was screened via computer number NEW002TMD on 04 /15/2026 and tested using digital refractometer number 14514-1020. 7. The CMS showed that digital refractometer 14514-1020 was out of service on 04/15/2026 and had been replaced with digital refractometer 14517-1020 on 12/17/2025. 8. The procedure titled "Daily Area Cleaning and Work Area Guidelines" stated that "When placing screening equipment in service, update the Computer Name field in the asset record in CMS to reflect the DIS workstation associated with the equipment prior to use" and the "Digital Refractometer (also requires update in DIS if moved, removed Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- from or placed into service)." 9. During the exit interview on 04/24/2026 at 1:50 PM, the QMR confirmed that digital refractometer number 14514-1020 was not removed from the DIS when it was placed out of service. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 20, 2022

Survey Type: Standard

Survey Event ID: 2ZKJ11

Deficiency Tags: D5417 D5417

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on review of the quality control (QC) records and interview with the laboratory manager, the laboratory failed to ensure that distilled water used for calibration of the digital refractometer was not used after the expiration date. Findings: 1. The QC records from 2022 for the digital refractometer chemistry analyzer were reviewed. 2. The records did not include the lot numbers and expiration dates of the distilled water used as the zero control to verify each analyzer prior to testing the low and high QC materials. Once the QC materials are found to be acceptable the analyzer is used for testing the donors. If the zero control fails the analyzer is removed from service and the require repairs are performed. 3. During the survey on 10/20/22 at 12:15 PM, the laboratory manager confirmed that the records did not include the lot numbers and expiration dates of the distilled water used as the zero control for each analyzer prior to being used to test donors. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access