Booth Dermatology Group, Pc

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 15D0691800
Address 12050 N Michigan Rd, Zionsville, IN, 46077
City Zionsville
State IN
Zip Code46077
Phone(317) 848-2427

Citation History (2 surveys)

Survey - January 25, 2023

Survey Type: Standard

Survey Event ID: QI6611

Deficiency Tags: D5219 D5311 D5413

Summary:

Summary Statement of Deficiencies D5219 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(2) At least twice annually, the laboratory must verify the accuracy of any test or procedure listed in subpart I of this part for which compatible proficiency testing samples are not offered by a CMS-approved proficiency testing program. This STANDARD is not met as evidenced by: Based on record reviews and interview, the laboratory failed to verify the accuracy of MOHS Microscopic Surgery (MOHS) testing twice annually in 2021 and 2022. Findings Included: 1. The "Quality Assurance Program" policy, reviewed by the laboratory director on 9/15/2022, read "B. Proficiency Testing The laboratory will be active in a CLIA approved proficiency testing program." The policy did not state proficiency testing must be performed twice annually. 2. The "Slide Exchange Agreement", signed by the laboratory director on 10/25/2022, stated... "Slides will be sent/picked up and brought to 'Laboratory B' for review and diagnosis." The agreement did not mention the slides would be exchanged twice annually. 3. Review of slide exchange documentation labeled "Dermatopathology Proficiency Test" with Laboratory B from 2021 and 2022 revealed the following: a.) Slides were exchanged on 10/15/2021 for 10 cases and was signed by laboratory director on 10/10/2021. b.) Slides were exchanged on 10/26/2022 for 10 cases and was signed by laboratory director on 10/25/2022. 4. During an interview on 1/25/2023 at 2:37 PM, Sp-1 (Laboratory Director) confirmed verification of MOHS testing was not completed in 2021 and 2022. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to label the correct specimen number for one (PT#1) out of eight patients reviewed for MOHS testing. Findings Included: 1."Mohs Surgery Slides" policy signed by laboratory diector on 10 /22/2022, read ,"The slides will be labeled with the mounting number of the patient, correlating to map number." 2. Two patient cases reviewed PT#1 and PT#2 had the specimen number 076-21 on all slides. Slides for PT#1 and PT#2 had last names and first initials that were different, but had the same specimen number. 3. The handwritten Mohs map for PT#1 dated 7/14/2021 had the specimen number as MT#076-21 4. Mohs Log revealed the following : a.) PT#1 specimen number 075-21 b.) PT#2 specimen number 076-21 5. The "Progress Note" for PT#1 which included the Mohs Map listed the specimen number "Mohs #075-21" 6. The "Visit Note" for PT#1 listed the Mohs Case Number as "075-21". The visit note included the copy of the Mohs Map. 7. During interview on 1/25/2023 at 2:37 PM, SP-1 (Laboratory Director) confirmed the slides for PT#1 were labeled incorrectly. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based observation, record review and interview, the laboratory failed to document humidity for Avantik Cryostat (QS11/QS11UV) for 24(January 2021 to December 2022) of 24 months reviewed in 2021 and 2022. Findings Included: 1. During a tour of the MOHS Lab on 1/25/2023 at 10:33 AM, revealed a cryostat Avantik (QS11 /QS11UV) used for MOHS testing. 2. Review of "Technical Data QS11/QS11UV" stated "operating conditions + 5 Celsius(C) up to +35 C (at a max rel. humidity of 60%) 3. Review of "Daily Quality Control Log-Month/Year" from January 2021 to December 2022 indicated humidity was not documented. 4. During an interview on 1 /25/2023 at 2:37 PM, Sp-1 (Laboratory Director) confirmed that humidity was not recorded for the cryostat for 24 of 24 months reviewed in 2021 and 2022. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 29, 2018

Survey Type: Standard

Survey Event ID: PBO511

Deficiency Tags: D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: The Standard is not met as evidenced by: Based on observation, document review, and interview, the laboratory failed to document compliance with manufacturer's maintenance requirements for one of one cryostat (Avantik Cryostat, serial #51722) in use during 2018, for one of twelve patients (P-8) reviewed in the subspecialty of Histopathology. Findings include: 1) On 10/20/18 at 12:30 PM, during tour an AVANTIK Cryostat, serial #51722, was in operation. 2) Review of AVANTIK "EQUIPMENT QUALITY CONTROL---CRYOSTAT", no approval date, indicated the following maintenance procedures were required: a) defrost of machine daily; b) change of cryostat blade at least every 20th case; c) clean condenser coils; d) annual change of air filter; e) weekly oil of flywheel and components; f) document problems with cryostat; g) deep cleaning every six months. 3) Review of laboratory log "Maintenance Record---Cryostat", indicated the above maintenance was not completed on the following dates: a) January 2018 to June 2018, a, b, c, d, f, and g, were not documented; and, e was not documented on March 29 and May 3. b) July 2018 to October 2018, a, b, c, d, f, and g were not documented; and, e was not documented July 12, August 23, September 13, and October 4. 4) Review of test report for patient P-8 testing date (05-10-18), indicated six of nine (a, b, c, d, f, and g) maintenance steps were not documented for the cryostat, when patient P-8 was tested (1404 histopathology tests performed annually). 5) In interview on 10/29/18 at 2:30 PM, SP-1 indicated the following: a) cryostat is defrosted as needed, but not documented; b) the cryostat blade is changed daily, if not more on Mohs surgical procedure days, but not documented; c) the flywheel and moving parts are oiled Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- weekly, but not always documented; d) issues with the cryostat are corrected, but not documented; and, e) the lab has maintenance on the cryostat yearly, but could not provide documentation for the detail of work done. 6) In interview on 10/29/18 at 2: 36 PM, SP-2 indicated the following: a) condenser coils are cleaned after each Mohs, but not documented; b) the air filter of the fume hood is changed at the annual inspection (could not provide detail of service); and, c) deep cleaning is performed every six months, but not documented. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility