Summary:
Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: The Standard is not met as evidenced by: Based on observation, document review, and interview, the laboratory failed to document compliance with manufacturer's maintenance requirements for one of one cryostat (Avantik Cryostat, serial #51722) in use during 2018, for one of twelve patients (P-8) reviewed in the subspecialty of Histopathology. Findings include: 1) On 10/20/18 at 12:30 PM, during tour an AVANTIK Cryostat, serial #51722, was in operation. 2) Review of AVANTIK "EQUIPMENT QUALITY CONTROL---CRYOSTAT", no approval date, indicated the following maintenance procedures were required: a) defrost of machine daily; b) change of cryostat blade at least every 20th case; c) clean condenser coils; d) annual change of air filter; e) weekly oil of flywheel and components; f) document problems with cryostat; g) deep cleaning every six months. 3) Review of laboratory log "Maintenance Record---Cryostat", indicated the above maintenance was not completed on the following dates: a) January 2018 to June 2018, a, b, c, d, f, and g, were not documented; and, e was not documented on March 29 and May 3. b) July 2018 to October 2018, a, b, c, d, f, and g were not documented; and, e was not documented July 12, August 23, September 13, and October 4. 4) Review of test report for patient P-8 testing date (05-10-18), indicated six of nine (a, b, c, d, f, and g) maintenance steps were not documented for the cryostat, when patient P-8 was tested (1404 histopathology tests performed annually). 5) In interview on 10/29/18 at 2:30 PM, SP-1 indicated the following: a) cryostat is defrosted as needed, but not documented; b) the cryostat blade is changed daily, if not more on Mohs surgical procedure days, but not documented; c) the flywheel and moving parts are oiled Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- weekly, but not always documented; d) issues with the cryostat are corrected, but not documented; and, e) the lab has maintenance on the cryostat yearly, but could not provide documentation for the detail of work done. 6) In interview on 10/29/18 at 2: 36 PM, SP-2 indicated the following: a) condenser coils are cleaned after each Mohs, but not documented; b) the air filter of the fume hood is changed at the annual inspection (could not provide detail of service); and, c) deep cleaning is performed every six months, but not documented. -- 2 of 2 --