Brenham Dermatology

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 45D2097493
Address 1910 Neibuhr Street, Brenham, TX, 77833
City Brenham
State TX
Zip Code77833
Phone(979) 353-4267

Citation History (2 surveys)

Survey - October 9, 2026

Survey Type: Standard

Survey Event ID: 14AA11

Deficiency Tags: D0000 D5217 D3031 D6128

Summary:

Summary Statement of Deficiencies D0000 The Brenham Dermatology laboratory was found to be in compliance with the Conditions of the CLIA regulations found at 42 CFR 493.1 through 493.1780, CLIA requirements for laboratories as a result of a recertification survey on 10/09/2026 and recertification is recommended. Standard level deficiencies were cited. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. In addition, retain the following: This STANDARD is not met as evidenced by: Based on review of the laboratory's policy and procedure, reagent log, interview, and presurvey paperwork, the laboratory failed to retain the chemical name and concentration (if applicable), manufacturer, lot number, expiration date, received date, and open date of the chemicals and stains for the Hematoxylin and Eosin (H&E), Toluidine Blue (T. Blue), and MART 1 stains used in the laboratory for Mohs testing for 24 of 24 months reviewed from 10/09/2024 - 10/09/2026. Findings follow. A. Review of the laboratory's policy and procedure titled Laboratory Policy and Procedure Manual, no approval date, did not include a section for the documentation of chemicals and stains. B. The reagent log was requested on October 9, 2026 at 12:40 hours but not provided. C. Interview with the histotech on October 9, 2026 at 12:40 hours in the breakroom confirmed chemical and stain records such as lot number, expiration date, open date and received date were not retained by the laboratory. D. Review of the CMS Form 116 showed an estimated annual volume of 6112 Mohs blocks and special stains. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of laboratory's policy and procedure, accuracy assessments, and interview, the laboratory failed to perform twice a year accuracy assessments of its Frozen Section Biopsies for the dermatopathology interpretations for three of four events in 2024 and 2025. Findings follow. A. Review of the laboratory's policy and procedure titled Laboratory Policy and Procedure Manual, no approval date, at B. Proficiency Testing stated "2. For permanent section histology, slides representing two biopsies will be submitted for review by another CLIA- certified laboratory every six months. Slides should represent both malignant and benign diagnoses." B. One peer review was reviewed from 2025, additional accuracy assessments for the dermatopathology interpretations of Frozen Section Biopsies were requested on October 9, 2026 at 1200 hours but not provided. C. Interview with the Laboratory Director on October 9, 2026 at 1230 hours in the breakroom confirmed twice a year accuracy assessments for frozen section biopsies were not performed. D6128 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) (b)(9) Thereafter, evaluations must be performed at least annually unless test methodology or instrumentation changes, in which case, prior to reporting patient test results, the individuals performance must be reevaluated to include the use of the new test methodology or instrumentation. This STANDARD is not met as evidenced by: Based on review of the laboratory's policy and procedure, competency evaluations, pre-survey paperwork, and interview, the technical supervisor failed to evaluate and document the performance of Mohs surgeons responsible for high complexity testing in Mohs testing at least annually for two of two years reviewed in 2024 and 2025. Findings follow. A. Review of the laboratory's policy and procedure titled Laboratory Policy and Procedure Manual, no approval date, at C. Competency Assessment, stated, "Purpose: Laboratory personnel will be evaluated and assessed at 6 and 12 months and on an annual basis thereafter to assess their competency in cutting tissue, and the various staining procedures." The policy and procedure did not include Mohs surgeons performing patient testing. B. Review of annual competency evaluations for Mohs surgeons showed no competency evaluations for Mohs surgeons performing testing in 2024 and 2025 for testing personnel #2 (as listed on the CMS Form 209, testing personnel #1 also listed as Laboratory Director). Competency evaluations were requested on October 9, 2026 at 1115 hours but not provided. C. Review of the CMS Form 116 showed an estimated annual volume of 6112 Mohs blocks and special stains. D. Interview with the Office Manager on October 9, 2026 at 1115 hours in the breakroom confirmed the technical supervisor did not perform competency evaluations for Mohs surgeons performing patient testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 5, 2024

Survey Type: Standard

Survey Event ID: IVQ011

Deficiency Tags: D5415 D5415 D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on observations, review of manufacturer's instructions and interview of facility personnel, the laboratory failed to store 4 of 4 bottles of StatLab Treosin stain (used in histopathology for staining of tissues) as defined by the manufacturer. The findings included: 1. observations made in the laboratory found 4 of 4 bottles of Treosin stored in the cabinet above the automated stainer. 2 bottles each of lots 203270 expiration 2026-01-31 and lot 189836 expiration 2025-7-31. 2. Review of storage instructions found on the labels of the Treosin stain found under the heading STORAGE: "Store in a fireproof dry, cool and well ventilated place". 3. During interview of the histotechnologist conducted by phone on December 5, 2024 at 2:26 PM, she confirmed she did not store the Treosin stain as defined by the manufacturer. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- use. This STANDARD is not met as evidenced by: Based upon observations and interview of facility personnel the laboratory failed to label 4 of 4 secondary containers used for storage of tissue dyes (used for marking tissues) with the contents, preparation and expiration dates. The findings included: 1. Observations made in the laboratory found 4 unlabeled screw top containers filled with substances colored yellow, red, purple and black. 2. During interview of the office manager conducted December 5, 2024 at 2:41 PM, she confirmed the containers were not labeled and contained tissue marking dye. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access