Cancer Care Associates, P C

CLIA Laboratory Citation Details

4
Total Citations
28
Total Deficiencyies
15
Unique D-Tags
CMS Certification Number 23D0682375
Address 3577 W Thirteen Mile Road, Suite 404, Royal Oak, MI, 48073
City Royal Oak
State MI
Zip Code48073
Phone248 551-6900
Lab DirectorMICHAEL STENDER

Citation History (4 surveys)

Survey - November 21, 2024

Survey Type: Standard

Survey Event ID: KR8211

Deficiency Tags: D5016 D5024 D5313 D5313 D5417 D5433 D5445 D5893 D6020 D6021 D6029 D6029 D5024 D5209 D5209 D5417 D5433 D5445 D5893 D6000 D6000 D6020 D6021

Summary:

Summary Statement of Deficiencies D5016 ROUTINE CHEMISTRY CFR(s): 493.1210 If the laboratory provides services in the subspecialty of Routine Chemistry, the laboratory must meet the requirements specified in 493.1230 through 493.1256, 493. 1267, and 493.1281 through 493.1299. This CONDITION is not met as evidenced by: . Based on observations, record review, and interviews, the laboratory failed to follow testing personnel competency assessment policies and procedures (refer to D5209), failed to ensure controls and supplies were not used beyond expiration dates (refer to 5417), failed to establish maintenance activities for laboratory thermometers (refer to D5433) and failed to document chemistry quality control (refer to D5445A). D5024 HEMATOLOGY CFR(s): 493.1215 If the laboratory provides services in the specialty of Hematology, the laboratory must meet the requirements specified in 493.1230 through 493.1256, 493.1269, and 493. 1281 through 493.1299. This CONDITION is not met as evidenced by: . Based on record review and interview, the laboratory failed to follow testing personnel competency assessment policies and procedures (refer to D5417) and failed to document hematology quality control (refer to D5445B). D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 6 -- As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: . Based on record review and interview with the Office Manager (OM), the laboratory failed to follow testing personnel competency assessment policies and procedures for 1 (TP2) of 2 testing personnel. Findings include: 1. A record review of the laboratory's personnel records revealed that competency assessments were not conducted for Testing Personnel #2 (TP2) upon hire (February 14, 2024) nor in August of 2024 when TP2 commenced patient testing. 2. Review of laboratory policy titled "Personnel Experience, Qualifications and Training" revealed "...5. A personnel file is kept on each laboratory employee. This will include: a. Initial and 6-month training and competency documentation...". 3. An interview with the OM on 11/21 /2024 at 3:55 pm confirmed that competency assessment documentation for TP2 was not present at time of survey. D5313 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(b) The laboratory must document the date and time it receives a specimen. This STANDARD is not met as evidenced by: . Based on observation, record review and interview with Testing Personnel #1 (TP1), the laboratory failed to document the specimen collection time for two of four patient samples observed in the laboratory. Findings include: 1. On 11/21/24 at 1:22 pm, the surveyor observed two patient samples, a gold top blood collection tube and a green top blood collection tube, in the specimen processing area that were not labeled with the time the specimens were collected. 2. Review of the laboratory's policy titled "Specimen Collection and Handling" revealed "Patient Identification and Specimen Labeling ...Each specimen must be correctly identified and labeled with the following information: Patient's full name DOB Time and date of collection ..." 3.An interview on with TP1 at 11/21/2024 at 1:25 pm confirmed that collection times were not documented on the two patient samples observed. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: . Based on observation and interview with Testing Personnel #1 (TP1), the laboratory failed to ensure controls and supplies were not used beyond expiration dates for four items observed. Findings include: 1. During a tour of the laboratory on 11/21/2024 at 9:45 am the surveyor observed the following: a. Two bottles Bio-Rad Liquid Assay Controls with the expiration date of 11/20/2024. b. One bottle of Millipore Cleansing Tablets with the expiration date of 06/22/2022. c. One Millipore Water Filter with the -- 2 of 6 -- expiration date of 9/11/2024 installed on the Merck Water Filtration System for the laboratory's Siemens Dimension Expand Plus Chemistry Analyzer. 2. An interview was conducted with TP1 on 11/21/2024 at 10:00 am confirmed controls and supplies were expired. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. This STANDARD is not met as evidenced by: . Based on observation, record review, and interview with Testing Personnel #1 (TP1), the laboratory failed to establish maintenance activities for laboratory thermometers for 5 (July 2024-November 2024) of 5 months. Findings include: 1. On 11/21/2024 at 3:00 pm during tour of the back storage room the surveyor observed the following: a. A mini-refrigerator containing quality controls in the freezer compartment. The freezer was noted to have an accumulation of ice. The freezer thermometer displayed a temperature reading of -31 degrees Celsius. b. A stand alone refrigerator containing reagents in the refrigerated section. The thermometer of the refrigerated section displayed a temperature reading of 8 degrees Celsius. Further inspection of the thermometer revealed a calibration expiration date of 06/22/2024. 2. Record review of the laboratory's "Temperature Documentation For Minimax Thermometers" logs revealed thermometer calibration was not monitored. 3. An interview with TP1 on 11 /21/2024 at 3:05 pm confirmed the thermometer calibration had expired. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . A. Based on record review and interview with Testing Personnel #1 (TP1), the laboratory failed to document chemistry quality control for 9 (#1-9) of 10 patient testing dates requested for review. Findings include: 1. Record review for patients receiving chemistry testing revealed a lack of quality control documentation for the following 9 patient testing dates: a. Patient #1 had comprehensive metabolic panel (CMP), ferritin, and iron panel performed on 11/04/2024. b. Patient #2 had hepatic function panel (HFP) and basic metabolic panel (BMP) performed on 08/01/2024. c. -- 3 of 6 -- Patient #3 had CMP, magnesium, ferritin, and iron panel performed on 06/27/2024. d. Patient #4 had CMP performed on 06/05/2024. e. Patient #5 had CMP and magnesium performed on 05/13/2024. f. Patient #6 had CMP performed on 02/14/2024. g. Patient #7 had CMP performed on 11/15/2023. h. Patient #8 had CMP performed on 06/06 /2023. i. Patient #9 had CMP performed on 03/08/2023. 2. An interview with TP1 on 11/21/2024 at 3:00 pm confirmed quality control documentation was not retrievable. B. Based on record review and interview with Testing Personnel #1 (TP1), the laboratory failed to document hematology quality control for 10 (#1-10) of 10 patient testing dates requested for review. Findings include: 1. Record review for patients receiving hematology testing revealed a lack of quality control documentation for the following 10 patient testing dates: a. Patient #1 had complete blood count (CBC) with differential performed on 11/04/2024. b. Patient #2 CBC with differential performed on 08/01/2024. c. Patient #3 CBC with differential performed on 06/27/2024. d. Patient #4 CBC with differential performed on 06/05/2024. e. Patient #5 CBC with differential performed on 05/13/2024. f. Patient #6 CBC with differential performed on 02/14/2024. g. Patient #7 CBC with differential performed on 11/15/2023. h. Patient #8 CBC with differential performed on 06/06/2023. i. Patient #9 CBC with differential performed on 03/08/2023. j. Patient #10 CBC with differential performed on 1/03/2023. 2. An interview with TP1 on 11/21/2024 at 3:00 pm confirmed quality control documentation was not retrievable. D5893 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(b)(c) (b) The postanalytic systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 17, 2023

Survey Type: Standard

Survey Event ID: VYHI11

Deficiency Tags: D5301 D5301

Summary:

Summary Statement of Deficiencies D5301 TEST REQUEST CFR(s): 493.1241(a) The laboratory must have a written or electronic request for patient testing from an authorized person. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Manager, the laboratory failed to have a test request for testing ordered by providers outside the laboratory's practice for 1 (Patient #6) of 13 patient test records reviewed. Findings include: 1. A review of the laboratory's patient test reports revealed Patient #6 had the following testing performed on 5/26/22: a. Complete Blood Count b. Complete Metabolic Panel c. Lactate Dehydrogenase d. Iron e. Ferritin 2. A review of the laboratory's patient test requests revealed a lack of test request for Patient #6's testing performed on 5/26/22. 3. An interview on 1/17/23 at 9:59 am with the Laboratory Manager revealed Patient #6 had testing ordered from a provider outside of the laboratory's practice and a process to enter the test requests into the laboratory's system had not been established. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 13, 2021

Survey Type: Standard

Survey Event ID: XIY311

Deficiency Tags: D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: . Based on lack of documentation and interview with the Technical Consultant (TC) and Testing Personnel (TP) #3, the laboratory failed to perform and document the annual preventive maintenance (PM) for the AFS 3D water system for 2 (September 2019 -September 2021) of 2 years reviewed. Findings include: 1. Record review revealed the lack of documentation of the annual PM for the AFS 3D water system for 2 (September 2019 - September 2021) of 2 years reviewed. 2. An interview on 9/13 /2021 at 1:10 pm, the TC and TP#3 confirmed the PM was not performed and documented. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 6, 2019

Survey Type: Standard

Survey Event ID: J8XM11

Deficiency Tags: D3031 D3031

Summary:

Summary Statement of Deficiencies D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: . Based on record review and interview with Testing Personnel #2 (TP2), the laboratory failed to retain the daily hematology Abbott Cell-Dyn Ruby instrument background count records for 2 (June 2017 to June 2019) of 2 years reviewed. Findings include: 1. Record review revealed the daily background counts were not maintained for 2 years as follows: a. Patient testing on 06/06/2017 b. Patient testing on 09/12/2017 c. Patient testing on 12/14/2017 d. Patient testing on 05/21/2018 2. During the interview on June 6, 2019 at approximately 12:30 pm, TP2 acknowledged the Abbott Cell-Dyn Ruby instrument would not access background counts back 2 years. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary