Carson Valley Health

CLIA Laboratory Citation Details

2
Total Citations
11
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 29D0876062
Address 1107 Us Highway 395 N, Gardnerville, NV, 89410
City Gardnerville
State NV
Zip Code89410
Phone(775) 782-1500

Citation History (2 surveys)

Survey - December 1, 2020

Survey Type: Standard

Survey Event ID: 55VB11

Deficiency Tags: D0000

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was generated as a result of the onsite CLIA recertification survey conducted at your facility on 12/01/2020. The laboratory was found to be in compliance with 42 CFR Part 493, Requirements for Laboratories. The findings and conclusions of any investigation by the Division of Public and Behavioral Health shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state or local laws. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 15, 2018

Survey Type: Standard

Survey Event ID: 9DDN11

Deficiency Tags: D0000 D5217 D5221 D5429 D5781 D0000 D5217 D5221 D5429 D5781

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was created as a result of an on-site CLIA recertification survey conducted at your facility on 8/15/18. The findings and conclusions of any investigation by the Division of Public and Behavioral Health shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state, or local laws. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of the American Proficiency Institute (API) proficiency testing (PT) evaluations, review of laboratory records, and interview with the laboratory manager, the laboratory failed to verify the accuracy of the sperm morphology test consisting of the sperm classification and per cent (%) normal sperm for 2017. Findings include: 1. The laboratory did not have a system in place to verify the accuracy of the sperm morphology test at least twice annually when the API PT test evaluations of the laboratory results were not graded. 2. Review of the API PT evaluations and laboratory records revealed for the first event of 2017 that four of ten sperm classification results were not graded and two of two % normal sperm results were not graded. 3. For the second test event (identified by API as the third event) of 2017, five of ten sperm classification results were not graded and two of two % normal sperm results were not graded. The laboratory manager confirmed the finding during the on- site survey on 8/15/18 at approximately 10:00 AM and indicated that the laboratory performed approximately six sperm morphology tests annually. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on review of American Proficiency Institute (API) proficiency testing (PT) evaluations, review of laboratory records, and interview with the laboratory manger, the laboratory failed to document PT evaluations and PT verification activities for sperm morphology consisting of sperm classification and percent (%) normal sperm for the two PT events of 2017 and the first PT event of 2018. Findings include: 1. Review of the API PT sperm morphology evaluation for the first event of 2017 showed that two of ten PT reported results for sperm classification did not match the expected results. No

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access