Center For Dermatology

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 21D2132556
Address 19236 Meadow View Drive, Hagerstown, MD, 21742
City Hagerstown
State MD
Zip Code21742
Phone(240) 347-4937

Citation History (2 surveys)

Survey - September 9, 2026

Survey Type: Standard

Survey Event ID: 3XYG11

Deficiency Tags: D5403 D6046

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) (b) The procedure manual must include the following when applicable to the test procedure: (b)(1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (b)(2) Microscopic examination, including the detection of inadequately prepared slides. (b)(3) Step-by- step performance of the procedure, including test calculations and interpretation of results. (b)(4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (b)(5) Calibration and calibration verification procedures. (b)(6) The reportable range for test results for the test system as established or verified in 493.1253. (b)(7) Control procedures. (b)(8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 16, 2021

Survey Type: Standard

Survey Event ID: GQJQ11

Deficiency Tags: D5417 D5429

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on record review and interview with laboratory staff, the laboratory did not document the expiration date of reagents, stains used to stain and ink tissue for histopathology. Findings: 1. The laboratory reagent receipt and use log did not include the expiration date of reagents and stains; and 2. This was confirmed with staff during the exit with the laboratory staff at noon on the day of survey. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on review of the cryostat daily preventive maintenance record and interview with laboratory staff, the laboratory did not document the temperature of the cryostat each day of use. Findings: 1. The preventive maintenance record did not include the daily temperature of the cryostat each day of use; and 2. This was confirmed with staff during the exit with the laboratory staff at noon on the day of survey. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --