Centracare Laboratory Services - Albany

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 24D0405820
Address 30 Railroad Ave, Albany, MN, 56307
City Albany
State MN
Zip Code56307
Phone320 845-6105
Lab DirectorBRADLEY CURTIS

Citation History (3 surveys)

Survey - March 18, 2026

Survey Type: Standard

Survey Event ID: 9MMP11

Deficiency Tags: D0000 D5445 D5421 D6005

Summary:

Summary Statement of Deficiencies D0000 The CentraCare Laboratory Services - Albany laboratory was found to be out of compliance with the regulations of the Clinical Laboratory Improvement Amendments of 1988 (42 C.F.R. part 493) upon completion of the recertification survey performed on March 18, 2026. The following standard-level deficiency was cited: 493.1253 Establishment and verification of performance specification 493.1256 Control procedures 493.1407 Laboratory director responsibilities . D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) (b) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (b)(1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (b)(1)(i) (A) Accuracy. (b)(1)(i)(B) Precision. (b)(1)(i)(C) Reportable range of test results for the test system. (b)(1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: . Based on observation, document review, and interview with laboratory personnel, the laboratory failed to complete all required Performance Verification (PV) activities prior to reporting patient test results for one of one Chemistry analytes implemented in 2026. Findings are as follows: 1. The laboratory performed Chemistry testing as confirmed by the General Supervisor 1 during a tour of the laboratory at 11:05 a.m. on 03/18/26. 2. An Abbott i-STAT blood analyzer was observed as present and available for use during the tour. The laboratory implemented high-sensitivity Troponin I (hs- TnI) testing using the i-STAT on 03/02/26. 3. High Sensitive Troponin Test PV documentation approved by the laboratory director on 03/05/26 included accuracy, reference range, and linearity verification data completed in February and March 2026. Precision verification documentation was not found. 4. Precision verification Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- was required for new non-waived tests as established in the Method Performance Specifications procedure provided by the laboratory on date of survey. 5. The Technical Consultant (TC) indicated 14 patients received hs-TnI testing on the i- STAT analyzer since test implementation to 03/18/26. 6. In an interview at 1:20 p.m. on 03/18/26, the TC confirmed the above finding. . D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) (d) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493. 1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (d)(3) At least once each day patient specimens are assayed or examined perform the following for: This STANDARD is not met as evidenced by: . Based on observation, document review, and interview with laboratory personnel, the laboratory failed to perform minimum quality control (QC) activities required for a Chemistry analyte in 2026. Findings are as follows: 1. The laboratory performed Chemistry testing as confirmed by General Supervisor 1 during a tour of the laboratory at 11:05 a.m. on 03/18/26. 2. An Abbott i-STAT blood analyzer was observed as present and available for use during the tour. The laboratory implemented high-sensitivity Troponin I (hs-TnI) testing using the i-STAT on 03/02/26. 3. QC testing with 2 levels of material was required for new hs-TnI lots and shipments and every 30 days as established in the i-STAT hs-TnI procedure found in the iSTAT FIB, HCG, Mono, Strep, Flu, POC INR manual. The QC documentation log indicated hs- TnI QC was performed on 02/12/26 and 03/12/26. 4. An i-STAT hs-TnI Individualized Quality Control Plan (IQCP) to reduce the frequency of QC testing was not found during review of laboratory records. The laboratory was unable to provide an hs-TnI IQCP upon request. 5. 14 patients received hs-TnI test results from implementation to 03/18/26 as indicated by the Technical Consultant (TC). 6. In an interview at 3:20 p.m. on 03/18/26, the TC confirmed the above finding. . D6005 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(c) (c) The laboratory director must: (c)(1) Be onsite at least once every 6 months, with at least 4 months between the minimum two on-site visits. Laboratory directors may elect to be on-site more frequently and must continue to be accessible to the laboratory to provide telephone or electronic consultation as needed; and (c)(2) Provide documentation of these visits, including evidence of performing activities that are part of the laboratory director responsibilities. This STANDARD is not met as evidenced by: . Based on observation, document review, and interview with laboratory personnel, the laboratory director (LD) failed to perform a site visit in 2025. Findings are as follows: 1. The laboratory performed moderate complexity Microbiology, -- 2 of 3 -- Immunology, Chemistry, and Hematology testing as indicated by General Supervisor 1 during a tour of the laboratory at 11:05 a.m. on 03/18/26. 2. The following analyzers, devices, and test kits were observed as present and available for use during the tour: Quidel Sofia infectious disease analyzer Abbott Architect c4000 chemistry analyzer Abbott i-STAT blood analyzer MEDTOXScan drugs of abuse test system DxH hematology analyzer Alcor miniiSED ESR analyzer Sysmex CA600 coagulation analyzer Cardinal Health hCG Combo test kit Nikon Eclipse microscope for manual differential and urine sediment examinations 3. Documentation of an LD site visit was not found during review of 2025 laboratory records and documents. 4. Twice annual laboratory director site visits were required as established in the Medical Director Responsibility procedure provided by the laboratory on data of survey. 5. In an interview at 2:35 p.m. on 03/18/26, the Technical Consultant confirmed the above finding and indicated the LD had not performed a site visit in 2025. . -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 22, 2021

Survey Type: Standard

Survey Event ID: 71NU11

Deficiency Tags: D2010

Summary:

Summary Statement of Deficiencies D2010 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(2) The laboratory must test samples the same number of times that it routinely tests patient samples. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to ensure Hematology and Microbiology proficiency testing (PT) samples from two of five Hematology PT events and one of five Microbiology events reviewed from 2020 through mid 2021 were tested consistent with the number of times the laboratory routinely tested patient specimens. Findings are as follows: 1. The laboratory performed Hematology and Microbiology testing as confirmed by the Testing Personnel 1 (TP1) during a tour of the laboratory at 11:00 a.m. on 12/22/21. 2. The laboratory performed PT in 2020 and 2021 using the American Proficiency Institute proficiency testing provider. 3. The Proficiency Testing Policy found in the Lab Test Manual indicated PT samples would be tested in the same manner as patient specimens. 4. The Blood Cell Identification (BCI), Differential (Diff), Vaginal Wet Preparation with KOH (VKP), Vaginal Wet Preparation (VA), Urine Sediment (US), and Potassium Hydroxide slide (KOH) PT samples were tested by multiple testing personnel (TP) prior to the event submission deadline for three PT events as indicated on attestation statements and handwritten result documents. See below. 2020 - Hematology 2nd event Submission deadline 07/13/20 Samples BCI-06 through BCI- 10 Diff-02 VKP-02 VA-02 US-03 and US-04 Tested by TP1 and TP3 on 07/03/20 2021 - Microbiology 2nd event Submission deadline 07/07/21 Samples KOH-03 Tested by TP1 and former TP PS on 07/01/21 2021 - Hematology 3rd event Submission deadline 11/23/21 Samples BCI-11 through BCI-15 VKP-03 VA-03 US- 05 and US-06 Tested by TP2 on 11/11/21 and TP4 on 11/09/21 5. In an interview at 1: 40 p.m. on 12/22/21, TP1 confirmed the above finding. . Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 25, 2018

Survey Type: Standard

Survey Event ID: TTRS11

Deficiency Tags: D5403 D5435 D6052 D5421 D5775

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access