CLIA Laboratory Citation Details
05D2061756
Survey Type: Special
Survey Event ID: QFO311
Deficiency Tags: D2096 D6016 D2016 D6000
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the subspecialty of Routine Chemistry constituting unsuccessful PT performance. (See D2096) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Creatine, resulting in an "initial" (first) unsuccessful performance. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for the analyte, Creatine, as follows: 2017 Q2 (20%) 2018 Q1 (40%) Q1 = First Testing Event Q2 = Second Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an initial unsuccessful performance for the analyte, Creatine. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, Creatine, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performance. (See D2016 and D2096) -- 2 of 2 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: ETFR11
Deficiency Tags: D5217 D6016 D2087 D5411 D6020
Summary Statement of Deficiencies D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing result reports, and interview with the laboratory staff, it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. The findings included: a. The laboratory performed routine chemistry testing, including but are not limited to the followings, Creatine (Cre), ALT/SGPT (ALT) and Blood gas pO2. b. In order to ensure the accuracy of the laboratory testing system annually, the laboratory enrolled its PT with API (American Proficiency Institute) PT programs. c. The laboratory attained scores of 40% for ALT and pO2 in the 1st 2017 PT event and a score of 20% for Cre in the 2nd 2017 PT event, which were unsatisfactory analyte performance for the testing events. d. The laboratory performed and reported test results of analyte Cre in approximately 500 patient samples monthly. e. The laboratory performed and reported test results of analyte ALT in approximately 39 patient samples monthly. f. The laboratory performed and reported test results of analyte pO2 in approximately 15 patient samples monthly. g. The laboratory staff affirmed (02/20/2018 @ 12:45 PM) that the laboratory failed to attained scores of at least 80 percent of acceptable responses for each analyte in each testing event were unsatisfactory analyte performance for the testing events. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing (PT) result reports, and interview with the laboratory staff, it was determine that the laboratory failed to verify, at least twice annually, the accuracy of any test or procedure it performed that is not included in subpart I of 42 CFR part 493. The findings included: a. The laboratory performed TDM (Therapeutic Drug Management) testing including vacomycin, which is not listed in the subpart I of 42 CFR part 493. b. In order to ensure the accuracy of any test or procedure it performed, the laboratory elected to enroll a PT program provided by API. c. The laboratory attained a score of 40% for vancomycin in the 3rd 2017 PT event, which was unsatisfactory performance. d. The laboratory performed in approximately 20 patient samples monthly. e. The laboratory staff affirmed (02/20/2018 @ 13:45) that a score of 40% for vacomycin in the 3rd 2017 PT event was unsatisfactory performance. D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on observation of the laboratory testing systems, review of the temperature records, and interview with the laboratory staff, it was determined that the laboratory failed to follow the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system. The findings included: a. Observed a digital thermometer with a S/N 11284 and it was last calibrated in 12/2016 by RC, located in the equipment room. b. A past Max temperature was recorded at 9 oC which was out of the laboratory's acceptable range between 2 - 6 oC. c. Tried to reset and demonstrate how the features of this digital thermometer. d. It was noted that that thermometer did not work, after replaced a new battery. e. The laboratory staff the company's Bio Medical Engineering Department was in charge of the maintenance of the thermometer. f. The laboratory staff affirmed (02/20/2018 @10:45 AM) the thermometer was broken. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing (PT) result reports, and -- 2 of 3 -- interview with the laboratory staff, it was determine that the laboratory director failed to ensure that the proficiency testing samples were tested as required under Subpart H of 42 CFR part 493. The findings included: See D-2087 and D-5217 D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing (PT) result reports, and interview with the laboratory staff, it was determine that the laboratory director failed to ensure that the quality control program was established and maintained to assure the quality of laboratory services provided . The findings included: See D-5411 -- 3 of 3 --
Get full access to the detailed deficiency summary for this facility