CMS Certification Number 34D1096968
Address 11301 Golf Links Drive North, Suite 205, Charlotte, NC, 28277
City Charlotte
State NC
Zip Code28277
Phone(704) 321-3376

Citation History (1 survey)

Survey - March 30, 2022

Survey Type: Standard

Survey Event ID: C57D11

Deficiency Tags: D5601 D5601

Summary:

Summary Statement of Deficiencies D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of the laboratory procedures, review of the manufacturer's instructions, review of QC(quality control) and patient records, and staff interview 3 /30/22, the laboratory failed to check and record negative reactivity each time of use for the MART-1 IHC(immunohistochemical) stain. Findings: The laboratory's "Positive and Negative Controls for Histopathology" procedure states, "..Normal skin specimens may be generated from excess tissue specimens that would normally be discarded and has been found to be negative for disease process on previous testing. These blocks would be negative controls for many studies..." The Bio-Care Medical MART-1 Cocktail product insert revealed, "limitations:...The clinical interpretation of any positive or negative staining should by complemented by morphological studies using proper positive and negative internal and external controls..." Review of MART- 1 QC logs revealed slide quality documented for each day slides are read. Review of a computer-generated patient and QC log revealed documentation for each case where MART-1 stain was performed. Approximately 625 patients had MART-1 IHC stain performed from time of last survey in May 2019 to March 2022, a period of approximately 34 months. At approximately 11:40 a.m., the Histotechnologist confirmed they are staining a positive control each time of use. She stated the computer-generated patient and QC log showed that the positive control was stained Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- correctly for each case performed. At approximately 12 p.m., the Laboratory Director confirmed they are only documenting the positive control reactivity for MART-1 IHC stain. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access