Chi Arthritis And Rheumatology

CLIA Laboratory Citation Details

1
Total Citation
1
Total Deficiency
1
Unique D-Tag
CMS Certification Number 04D2154508
Address 6 Shackleford Drive, Little Rock, AR, 72211
City Little Rock
State AR
Zip Code72211
Phone(501) 500-5001

Citation History (1 survey)

Survey - July 9, 2019

Survey Type: Standard

Survey Event ID: NK8T11

Deficiency Tags: D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: . Through a review of the validation studies for the Theratest DSX Immunoassay analyzer performed on November 29/2018, lack of documentation, and interview with staff, it was determined the laboratory failed to validate the method correlations for the DSX to verify that the manufacturer's reference intervals (normal ranges) are appropriate for the laboratory's patient population. As evidence by: A. The laboratory utilizes the Theratest DSX Immunoassay to process the following analytes: Single- Stranded Deoxyribonucleic Acid (ss-DNA), Double-Stranded Deoxyribonucleic Acid (dsDNA), Smith Antibody (SM), Ribonucleoprotein and Smith Antibodies (RNP/Sm), Sjogen-Syndrome Antigen A and B (SSA/SSB), Anti-topoisomerase 1 (ScL-70), Centromere, Anti-Cyclic Citrillinated Peptide (CCP ab), Rheumatoid factor (RF) Immunoglobin (Ig for A, G, and M), and Vitamin D (Vit D). B. A review of the validation studies for the Theratest DSX Immunoassay Analyzer performed on 11/29 /2018 revealed no data was present (at time of survey) to verify that the manufacturer's reference intervals (normal ranges) are appropriate for the laboratory's patient population. C. Upon request, the laboratory was unable to provide method correlation data for the validation of the Theratest DSX Immunoassay analyzer. D. In Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- an interview on 7/9/2019 at 11:00, the technical consultant (as listed on form CMS- 209) confirmed that method correlation studies were not performed as part of the validation of the Theratest DSX Immunoassay analyzer. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access