Clear Creek Dermatology

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 45D2258312
Address 904 Ford St, Llano, TX, 78643
City Llano
State TX
Zip Code78643
Phone(830) 953-1700

Citation History (2 surveys)

Survey - July 29, 2024

Survey Type: Standard

Survey Event ID: IYDK11

Deficiency Tags: D0000 D5403 D5413 D5413 D0000 D5403 D5781 D5781

Summary:

Summary Statement of Deficiencies D0000 The laboratory was surveyed and found to be in compliance with the Conditions of the CLIA regulations found at 42 CFR 493.1 through 493.1780, and recertification is recommended. Standard level deficiencies were cited. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 3, 2023

Survey Type: Standard

Survey Event ID: BFBO11

Deficiency Tags: D5417 D5429 D5417 D5429

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based upon observations and interview of facility personnel, the laboratory failed to ensure that expired Tissue Marking Dyes were not used in testing the 185 histopathology specimens as recorded on the CMS 116. The findings included: 1. Observations made during the tour of the laboratory found two bottles of expired Cancer Diagnostics, Inc. (CDI) Tissue Marker Dyes (Orange and Violet) in the cabinet. Expiration dates for the two dyes ( as labeled) was 2021-09-30. Testing Person one listed on the CMS 209 Laboratory Personnel report was observed using the expired CDI Tissue Marking Dye to mark tissues at 11:35 AM on January 3, 2023. 2. During interview of the histotechnician conducted January 3, 2023 at 11:37AM confirmed that the expired tissue marking dyes were currently being used in patient testing. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based upon review of the Operating instructions, maintenance records, and interview Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- of facility personal, the laboratory failed to perform and document monthly maintenance procedures for the Tanner Scientific Cryostat TN50 seven of seven months in 2022. The findings included: 1. Review of the Tanner Scientific Cryostat TN50 Operating instructions (2020-03-008.00) found in section 10.3 under the heading RECOMMENDED MAINTENANCE AND SERVICE SCHEDULE: Daily - Remove frozen section waste from the cryostat chamber after every day of usage. Disinfection if necessary. Weekly - Cleaning of the blade holder. Cleaning of the window. Monthly - Check of Temperature sensor in cryochamber. Cleaning of cryostat ventilation. 2. Review of the Maintenance Records for Cryostat for June - December 2022 (7 months) found no documentation of performing the Clean Air Filter maintenance procedure documented. 3. During interview of the histotechnician conducted January 3, 2023 at 11:22 AM, she confirmed she had not performed the monthly maintenance procedures as defined by the manufacturer. -- 2 of 2 --