Community Care Pocatello

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 13D1085881
Address 1595 Yellowstone Ave, Pocatello, ID, 83201
City Pocatello
State ID
Zip Code83201
Phone208 233-0032
Lab DirectorETHAN MCCARTY

Citation History (2 surveys)

Survey - March 2, 2026

Survey Type: Special

Survey Event ID: 5C6K11

Deficiency Tags: D2016 D2130

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a proficiency testing (PT) desk review of the Centers for Medicare and Medicaid (CMS) PT data report (Report 155D), graded results from the American Proficiency Institute (API) and a telephone interview with the laboratory manager on 02/11/2026, the laboratory failed to successfully participate in proficiency testing for the specialty hematology for the analyte Hematocrit (HCT) (non-waived) for 2 (two) out of 3 (three) events in 2025. See D 2130. D2130 HEMATOLOGY CFR(s): 493.851(f) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid (CMS) Proficiency Testing (PT) data report (Report 155D), graded PT results from the American Proficiency Institute (API), and an interview with the laboratory manager on 02/11 /2026, the laboratory failed to achieve satisfactory performance for two (2) out of three (3) PT events for the analyte hematocrit (HCT). The findings include: 1. A review of Report 155D and graded PT results from API identified that the laboratory failed to achieve satisfactory performance for events one (1) and three (3) in 2025 for the specialty of hematology for the analyte HCT. Analyte Event Score HCT (non- waived) 2025-1 60% HCT (non-waived) 2025-3 60% 2. An interview with the laboratory manager on 02/11/2026 at 1:45 PM confirmed the above findings. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 10, 2018

Survey Type: Standard

Survey Event ID: DSWR11

Deficiency Tags: D2015 D6053 D2007 D5805

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: Based on proficiency testing (PT) record review and an interview with the technical consultant, the laboratory failed to test PT samples for complete blood counts (CBCs) by the same personnel who perform patient testing since the last survey on September 7, 2016. Findings: 1. A PT record review from the American Proficiency Institute (API) revealed the laboratory failed to test the PT samples for CBCs by the personnel who routinely test patient CBCs. 2. An interview on April 10, 2018 at 8:20 AM, with the technical consultant, confirmed the laboratory failed to rotate the PT samples among all testing personnel who test patient CBCs since the last survey. D2015 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(5)(6) (5) The laboratory must document the handling, preparation, processing, examination, and each step in the testing and reporting of results for all proficiency testing samples. The laboratory must maintain a copy of all records, including a copy of the proficiency testing program report forms used by the laboratory to record proficiency testing results including the attestation statement provided by the PT program, signed by the analyst and the laboratory director, documenting that proficiency testing samples were tested in the same manner as patient specimens, for a minimum of two years from the date of the proficiency testing event. (6) PT is required for only the test system, assay, or examination used as the primary method for patient testing during the PT event. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on proficiency testing (PT) record review and an interview with the technical consultant, the laboratory director failed to sign the attestation statements from the American Proficiency Institute (API) for the specialty of Hematology for 2017. Findings: 1. An API PT record review from 2017, revealed the laboratory director failed to sign the attestation statements for the specialty of Hematology. 2. An interview on April 10, 2018 at 8:20 AM, with the technical consultant, confirmed the laboratory director failed to sign the attestation statements from 2017. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on a record review of final patient reports and an interview with the technical consultant, the laboratory failed to document the name and the address of the laboratory where complete blood counts (CBCs) were reported on patient for the period reviewed between January 7, 2018 through April 5, 2018. Findings: 1. A review of patient CBC test reports, revealed the name and the address of the laboratory failed to be included on the patient's test reports. 2. An interview on April 10, 2018, at 10:15 AM, with the technical consultant, confirmed the name and the address of the laboratory failed to be indicated on final patient reports. D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on a record review of personnel documents and an interview with the technical consultant, the laboratory failed to follow the laboratory policy to evaluate and document the competency at least semiannually for one new employee during the first year of patient testing on the Sysmex complete blood count (CBC) analyzer used to test CBCs since the last survey on September 7, 2016. Findings: 1. A record review of personnel documents revealed 1 out of 5 testing personnel listed on the CMS-209 Personnel Report form, failed to have a competency assessment performed at least semiannually during the first year of patient testing. 2. An interview on April 10, 2018, at 8:15 AM, with the technical consultant, confirmed the laboratory failed to perform competency at least semiannually on 1 testing personnel. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access