Complete Emergency Care City Base Llc

CLIA Laboratory Citation Details

4
Total Citations
22
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 45D2100324
Address 2619 Se Military Drive, Suite 101, San Antonio, TX, 78223
City San Antonio
State TX
Zip Code78223
Phone(210) 775-0705

Citation History (4 surveys)

Survey - January 7, 2026

Survey Type: Special

Survey Event ID: RM4E11

Deficiency Tags: D0000 D2096 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D0000 The following deficiencies are a result of a desk review of proficiency testing scores obtained from the national database and verified with the proficiency testing company. The facility was found to be out of compliance with the conditions of the CLIA program. The following CONDITION LEVEL DEFICIENCIES were found: D2016 - 42 C.F.R. 493.803 Condition: Successful participation [proficiency testing] D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute's proficiency reports, the laboratory failed to achieve satisfactory performance in two of two testing events for the analyte of potassium (refer to D2096) resulting in an initial unsuccessful performance. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) (f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute's proficiency reports (2025 events 2 and 3), the laboratory failed to achieve satisfactory performance for two of two events in 2025 for the analyte of potassium. The findings included: 1. A review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile report, the laboratory received the following unsatisfactory performances for potassium on two of two events: 2025 Event 2 60% 2025 Event 3 60% 2. A review of the American Proficiency Institute's proficiency testing reports from 2025 confirmed the findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute's proficiency testing reports from 2025 (Events 2 and 3), the laboratory director failed to provide overall management and direction of the laboratory services resulting in an initial proficiency testing failure for the analyte potassium (refer to D6016.) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on proficiency desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute's proficiency testing reports from 2025 (Events 2 and 3), the laboratory director failed to ensure successful participation in a HHS approved -- 2 of 3 -- proficiency testing program for the analyte of potassium for two of two events in 2025, resulting in an initial unsuccessful performance (refer to D2096). -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 22, 2024

Survey Type: Standard

Survey Event ID: EI6V11

Deficiency Tags: D1001 D1001 D5211 D5211 D5411 D5411

Summary:

Summary Statement of Deficiencies D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: Based on review of the manufacturer's package insert for the Roche CoaguChek XS, review of patient test records from October 1, 2023 to April 9, 2024, and staff interview, the laboratory failed to follow the manufacturer's instructions for three of five patients tested. The findings included: 1. A review of the manufacturer's package insert for the Roche CoaguChek XS (2020-12 V3.0) under the section titled "Purpose" determined: "The CoaguChek XS Plus System is intended for use by professional healthcare providers for quantitative prothrombin time testing for the monitoring of warfarin therapy." 2. A review of CoaguChek XS testing records from January 2023 to December 2023 identified the laboratory performed testing on five patients. A review of the patients records determined three of the five patients did not have a history of taking oral anticoagulation medication. They were: Date Identification Number 11/17 NUNPE000 12/09 CAMCA005 02/21 GALAR004 3. The technical consultant confirmed the findings in an interview conducted on 04/09/2024 at 1650 hours in the office. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on review of the laboratory's American Proficiency Institute's chemistry core proficiency testing results from 2022 and 2023, and staff interview, the laboratory failed to have documentation performing

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 22, 2022

Survey Type: Special

Survey Event ID: QTOU11

Deficiency Tags: D2016 D0000 D2096 D6000 D2016 D6016 D2096 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 Based on a proficiency testing desk review survey performed on September 22, 2022, the laboratory was found to be out of compliance based on the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 C.F.R. 493.803 Condition: Successful participation D6000 - 42 C.F.R. 493.1403 Condition: Laboratory Director, moderate complexity D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute evaluation reports, the laboratory failed to achieve successful performance in Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- two of two consecutive testing events for the specialty Routine Chemistry for the analyte Creatine Kinase (CK, Isoenzyme), resulting in unsuccessful performance. Refer to D2096. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute (API) Comparative Evaluations, the laboratory failed to attain a score of at least 80 percent for the analyte Creatine Kinase (CK), Isoenzyme in two of two consecutive testing events in 2022. The findings included: 1. Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute (API) Comparative Evaluations, the laboratory received the following unsatisfactory scores (satisfactory is 80% or greater) for the analyte Creatine Kinase (CK), Isoenzyme in the specialty of Routine Chemistry in two of two consecutive events: 2022 API 1st event 0% 2022 API 2nd event 60% D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute (API) proficiency testing records, the laboratory director failed to ensure successful participation in a HHS approved proficiency testing program for analyte Sodium in Routine Chemistry. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on desk review of the Certification and Survey Provider Enhanced Reporting -- 2 of 3 -- (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute (API) Comparative Evaluations, the laboratory director failed to ensure successful participation in a HHS approved proficiency testing program for analyte Creatine Kinase (CK), Isoenzyme in the specialty of Routine Chemistry for two of two events in 2022. Refer to D2096. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 3, 2018

Survey Type: Standard

Survey Event ID: 41UH11

Deficiency Tags: D0000 D1001

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative at the entrance and exit conferences. The facility representative was given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. Note: The CMS-2567 (Statement of Deficiencies) is an official, legal document. All information must remain unchanged except for entering the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access