Cooper Voorhees Campus

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 31D0700883
Address 900 Centennial Blvd, Voorhees, NJ, 08043
City Voorhees
State NJ
Zip Code08043
Phone(888) 499-8779

Citation History (2 surveys)

Survey - October 12, 2023

Survey Type: Standard

Survey Event ID: ROOG11

Deficiency Tags: D5469

Summary:

Summary Statement of Deficiencies D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of Quality Control (QC) records and interview with the Hematology Manager (HM), the laboratory failed to provide documentation for the establishment of the Sysmex e-Check (xs) quality control (QC) acceptable ranges on the Sysmex xs-1000i with each new lot from 4/27/21 to the date of the survey. The finding includes: 1. There was no documented evidence that QC acceptable ranges were established with each new lot. 2. The HM confirmed on 10/12/23 at 3:00 pm that new lots of QC had their acceptable ranges established but that they could not provide documentation due to limitations of the instrument software. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 27, 2021

Survey Type: Standard

Survey Event ID: P5LD11

Deficiency Tags: D5415 D6013 D5415 D6013

Summary:

Summary Statement of Deficiencies D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on surveyor observation of the Quality Control (QC) reagents and interview with the Technical Supervisor (TS), the laboratory failed to put a new expiration date on the Bioresource Technology Chemistry Control Liquid Assayed (BRT) reagents in use on the Abaxis Piccolo Xpress analyzer on the date of the survey. The findings include: 1. The Manufacturers Package Insert (MPI) stated "Thawed and unpinned: The Chemistry Control can be used for up to 14 days when stored unopened at 2-8C" 2. The laboratory did not put expiration date on the BRT QC after thawing. 3. The TS confirmed on 4/27/2021 at 11:10 am the laboratory failed to put new expiration date on the QC reagents. . D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on surveyor review of the Performance Specification (PS) records and interview with the Technical Supervisor (TS), the Laboratory Director (LD) failed to ensure that PS procedures performed on the Abaxis Piccolo Xpress were adequate from January 2021 to the date of survey. The findings include: 1. Chloride linearity established was 86.5-131.5 mmol/L but the laboratory used 80-135 mmol/L. 2. Creatine linearity established was .45-15.15 mg/dL but the laboratory used .2-20mg /dL.. 3. Glucose linearity established was 29.5-631.0 mg/dL but the laboratory used 10-700 mg/dL. 4. Lactate linearity established was 5.8-83.70 but the laboratory used 2.7-90 mg/dL. 5. Potassium linearity established was 2.35-7.45 mmol/L but the laboratory used 1.5-8.5 mmol/L. 6. Magnesium linearity established was .50-7.10 mg /dL but the laboratory used .1-8.0 mg/dL. 7. Sodium linearity established was 118- 159.5 mmol/L but the laboratory used 110-170 mmol/L. 8. Phosphorus linearity established was 1.50-15.55 mg/dL but the laboratory used .2-20 mg/dL. 9. Total Carbon Dioxidelinearity established was 8.5-35.0 mmol/L but the laboratory used 5- 40 mmol/L. 10. Aspartate Aminotransferase linearity established was 20.5-1366.5 U /L but the laboratory used 5-2000 U/L. 11. Alkaline Phosphatase linearity established was 24-1775 U/L but the laboratory used 5-2400 U/L. 12. Albumin linearity established was 1.85-5.90 mg/dL but the laboratory used 1-6.5 mg/dL. 13. Direct Bilirubin linearity established was .2-3.90 mg/dL but the laboratory used .1-5 mg/dL. 14. Total Bilirubin linearity established was was .3-4.40 mg/dL but the laboratory used .1-5 mg/dL. 15. Total Protein linearity established was 3.25-9.15 mg/dL but the laboratory used .2-14 mg/dL. 16. Blood Urea Nitrogen linearity established was 6.0- 115.0 mg/dL but the laboratory used 2-180 mg/dL. 17. Calcium linearity established was 5.15-15.35 mg/dL but the laboratory used 4-16 mg/dL. 18. The TS confirmed at 11:00 on 4/27/21 that PS records were not adequate. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access