Copiah County Medical Center

CLIA Laboratory Citation Details

3
Total Citations
9
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 25D0029746
Address 27190 Hwy 28, Hazlehurst, MS, 39083
City Hazlehurst
State MS
Zip Code39083
Phone(601) 574-7000

Citation History (3 surveys)

Survey - August 16, 2024

Survey Type: Standard

Survey Event ID: 76Y911

Deficiency Tags: D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of verification of performance specifications for the Ortho Clinical Diagnostics Vitros XT 7600 Integrated System, put in use for patient testing on 7/30 /2024, and the patient Specimen Log, the laboratory failed to verify accuracy, precision and reportable range for two tests of thirty-eight, performed on the Vitros XT Integrated System, before reporting test results on a total of twenty-four patients. Findings include: 1. Review of verification of performance specifications for the Ortho Clinical Diagnostics Vitros XT 7600 Integrated System and the patient Specimen Log, from 7/30/2024 through 8/16/2024, revealed the laboratory failed to verify accuracy, precision, and reportable range for phosphorus before reporting test results for the following twenty-three patients: 8/01/2024--Patients #177191, #175008. 8/02/2024--Patients #163788, #149406, #166640, #178843, #151469, #151588. 8/04/2024--Patients #177952, #181212, #139768. 8/05/2024--Patients #175008, #154183. 8/06/2024--Patient #140140. 8/07/2024--Patients #163584, #157265. 8/08/2024--Patients #141599, #175008. 8/12/2024--Patients #175008, #138505. 8/13/2024--Patient #173694. 8/14/2024--Patient #152284. 8/15/2024-- Patient #175008. 2. Review of verification of performance specifications for the Ortho Clinical Diagnostics Vitros XT 7600 Integrated System and the patient Specimen Log, from 7/30/2024 through 8/16/2024, revealed the laboratory failed to verify accuracy, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- precision, and reportable range for acetaminophen before reporting test results for Patient #142289 on 8/10/2024. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 27, 2022

Survey Type: Standard

Survey Event ID: 9K8111

Deficiency Tags: D2000

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) data system for proficiency testing, the laboratory's proficiency testing (PT) records since the last survey on 01/07/2021, and confirmation with the technical consultant, the laboratory failed to enroll in an HHS approved proficiency testing program for Rapid Plasma Reagin (RPR) for syphilis testing after the final testing event of 2020 when testing was begun with a new proficiency testing provider. Findings include: Review of the CMS data system for proficiency testing and the laboratory's PT records since the last survey on 01/07/2021 revealed no documentation of the performance of proficiency testing for RPR testing after the lab changed proficiency testing providers in January 2021. The technical consultant listed on the CMS 209 personnel form confirmed that the laboratory had tested 104 RPR's during the period when no RPR proficiency testing was performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 8, 2018

Survey Type: Standard

Survey Event ID: T32B11

Deficiency Tags: D5429 D6053 D6054 D6127 D5421 D6102 D6128

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of blood bank maintenance logs, lack of documentation of verification of performance specifications for the Ortho Clinical Diagnostics Micro- Typing System (MTS) Workstation, and interview with the general supervisor on 8-8- 18 at 4:30 p.m., the laboratory failed to document, as performed, verification of performance specifications for the Ortho Clinical Diagnostics MTS Workstation, before it was put in use for ABO/Rh, antibody detection, and compatibility patient testing on 3-28-17. Findings include: Review of blood bank maintenance logs revealed the Ortho Clinical Diagnostics MTS Workstation was put in use for ABO /Rh, antibody detection, and compatibility patient testing on 3-28-17. There was no documentation of verification of performance specifications available for review on the day of the survey, 8-8-18. In an interview on 8-8-18 at 4:30 p.m., the general supervisor, listed on the Centers for Medicare and Medicaid Services (CMS) 209 personnel form, confirmed there was no documentation of verification of performance specifications for the Ortho Clinical Diagnostics MTS Workstation. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on interview with the technical consultant on 8-8-18 at 4:35 p.m. and review of maintenance logs and the instrument printout for monthly maintenance for the Ortho Clinical Diagnostics Vitros 5600 Integrated immunoassay and chemistry system from 2-23-17 through 8-8-18, the laboratory failed to document, as performed, the monthly maintenance, as defined by the manufacturer, for the Vitros 5600 system for eleven months during this time frame. Findings include: Review of maintenance logs and the instrument printout for monthly maintenance for the Ortho Clinical Diagnostics Vitros 5600 Integrated immunoassay and chemistry system from 2-23-17 through 8-8-18 revealed the following monthly maintenance procedures were not documented as performed from 4-12-17 until 6-24-17, from 8-24-17 until 2-14-18, and from 2-14-18 through 8-8-18: Clean Cuvette Arm. Clean Cuvette Supply. Clean Cuvette Incubator. Clean PM Discard Chute. Clean and replace PM Evaporation Caps. Clean PM Incubator Slot and Insert Blade Channels. Clean CuveTip Cover and Ring area. Inspect and clean MicroTip Supply. Inspect and clean Supply 3 Reagent Carousel. Inspect and clean Supply 3 Housing and Cover. Inspect and clean Supply 3 MicroTip Pack Opener. Clean Supply 3 Tub and Bar Code Reader Window. Clean Vitros VersaTip Supply Registration Rails. Perform System Backup. In an interview on 8-8- 18 at 4:35 p.m., the technical consultant confirmed there was no documentation of performance of monthly maintenance for the Vitros 5600 system for these time frames. D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and personnel records since the last survey on 12-7-16, the technical consultant failed to evaluate and document the performance of Testing Personnel #1, #2, #3 and #10, responsible for moderate complexity testing at least semiannually during the first year these individuals tested patient specimens. D6054 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least annually, after the first year. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and personnel records since the last survey on 12-7-16, the technical -- 2 of 4 -- consultant failed to evaluate and document the performance of individuals responsible for moderate complexity testing at least annually. Findings include: Review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and personnel records since the last survey on 12-7-16 revealed the technical consultant failed to evaluate and document the performance of Testing Personnel #8 from 12-7- 16 until 8-8-18. D6102 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(12) The laboratory director must ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and review of personnel records since the last survey on 12-7-16, the laboratory director failed to ensure that prior to testing patient specimens Testing Personnel #10 received the appropriate training for moderate and high complexity testing and demonstrated that they could perform all testing operations reliably to provide and report accurate results. Findings include: Review of personnel records since the last survey on 12-7-16 revealed no documentation of training for Testing Personnel #10, date of hire 10-17-17, listed on the CMS 209 personnel form prior to performing moderate and high complexity testing on patient specimens. D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and personnel records since the last survey on 12-7-16, the technical supervisor failed to evaluate the competency and document the performance of Testing Personnel # 1, #2, #3 and #10 responsible for high complexity testing at least semiannually during the first year these individuals tested patient specimens. D6128 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least annually after the first year, unless test methodology or instrumentation changes, in which case, prior to reporting patient test results, the individual's performance must be reevaluated to include the use of the new test methodology or instrumentation. -- 3 of 4 -- This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form and personnel records since the last survey on 12-7-16, the technical supervisor failed to evaluate and document the performance of Testing Personnel #8 responsible for high complexity testing from 12-7-16 until 8-8-18. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access