Copper Queen Community Hospital

CLIA Laboratory Citation Details

7
Total Citations
46
Total Deficiencyies
25
Unique D-Tags
CMS Certification Number 03D2124326
Address 100 E 5th St, Douglas, AZ, 85607
City Douglas
State AZ
Zip Code85607
Phone(520) 805-6800

Citation History (7 surveys)

Survey - May 16, 2023

Survey Type: Standard

Survey Event ID: 8X0K11

Deficiency Tags: D2094 D2116 D3031 D2016 D2096 D2118 D5209 D5469 D5545 D6053 D6089 D6127 D5439 D5473 D5791 D6076 D6093

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Proficiency Testing (PT) reports for 2022 and 2023 sent to the State Agency by the PT provider, the laboratory failed to successfully participate in a PT program for the regulated analyte, AST(SGOT), under the subspecialty of Routine Chemistry, and the regulated analyte, Phenytoin, under the subspecialty of Toxicology, resulting in unsuccessful PT performance. Findings include: 1. The laboratory's PT performance was unsatisfactory for the first event of 2023 for the regulated analyte, AST(SGOT), with a score of 60%. 2. The laboratory's PT performance was unsatisfactory for the second event of 2023 for the regulated analyte, AST(SGOT), with a score of 60%. 3. Unsatisfactory participation in the first and Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 8 -- second events of 2023 (two consecutive testing events) for the regulated analyte, AST (SGOT), constitutes unsuccessful PT performance. 4. The laboratory's PT performance was unsatisfactory for the second event of 2022 for the regulated analyte, Phenytoin, with a score of 20%. 5. The laboratory's PT performance was unsatisfactory for the first event of 2023 for the regulated analyte, Phenytoin, with a score of 60%. 6. Unsatisfactory participation in the second event of 2022 and first event of 2023 (two out of three consecutive testing events) for the regulated analyte, Phenytoin, constitutes unsuccessful PT performance. D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on information the Proficiency Testing (PT) provider furnished to the State Agency for 2023, the laboratory failed to undertake appropriate training, technical assistance and remedial action necessary to correct problems associated with proficiency test failures for the regulated analyte, AST(SGOT). See D2016 for findings. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, AST(SGOT), for the first and second testing events of 2023 resulting in unsuccessful PT performance. See D2016 for findings. D2116 TOXICOLOGY CFR(s): 493.845(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. -- 2 of 8 -- This STANDARD is not met as evidenced by: Based on information the Proficiency Testing (PT) provider furnished to the State Agency for 2023, the laboratory failed to undertake appropriate training, technical assistance and remedial action necessary to correct problems associated with proficiency test failures for the regulated analyte, Phenytoin. See D2016 for findings. D2118 TOXICOLOGY CFR(s): 493.845(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, Phenytoin, for the 2nd event of 2022 and 1st event of 2023 resulting in unsuccessful PT performance. See D2016 for findings. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on lack of instrument printouts generated from the Triage Meter analyzer and interview with the technical consultant (TC-1), the laboratory failed to retain patient test records, including instrument printouts, for at least 2 years. Findings include: 1. The laboratory performs Brain Naturemic Peptide (BNP) testing on the Triage Meter analyzer under the specialty of Chemistry. 2. No documentation was presented for review during the survey conducted on May 16, 2023 to indicate the laboratory retained instrument printouts from the Triage Meter analyzer for at least 2 years. 3. The TC-1 interviewed on May 16, 2023 at 2:15 PM confirmed the laboratory failed to retain instrument printouts from the Triage Meter for at least 2 years. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on lack of employee competency policies and procedures for review and interview with the technical supervisor (TS-1), the laboratory failed to establish policies and procedures to assess the competency of the Technical Consultant (TC), Technical Supervisor (TS) and General Supervisor (GS). Findings include: 1. The -- 3 of 8 -- CMS-209, Laboratory Personnel form submitted for review during the survey conducted on May 16, 2023 listed two TC's, three TS's and one GS who provide technical oversight for testing performed in the specialties of Microbiology, Chemistry, Hematology and Immunohematology. 2. No documentation was presented for review to indicate the laboratory established policies and procedures to assess the competency of the TC's, TS's and GS. 3. The TS-1 interviewed on May 16, 2023 at 12: 05 PM confirmed the laboratory failed to have policies and procedures established to assess the competency of the laboratory personnel indicated above. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on lack of calibration verification documentation for the Sysmex XN550 hematology analyzer and interview with the technical supervisor (TS-1), the laboratory failed to perform and document calibration verification procedures as required. Findings include: 1. The laboratory uses a Sysmex XN550 analyzer to perform Complete Blood Count (CBC) testing in the specialty of Hematology. The laboratory's reported annual test volume for the specialty of Hematology is 23,960. 2. No documentation was presented for review from 2022 through May 16, 2023 to indicate the laboratory performed a calibration verification at least once every six months, including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results. Records reviewed for the Sysmex XN500 indicated a calibration verification was last performed on 11/05/2021. 3. The TS-1 interviewed on May 16, 2023 at 1:45 PM confirmed the laboratory failed to perform calibration verification activities on the Sysmex XN500 analyzer during 2022 through the date of the survey. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations -- 4 of 8 -- Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory's quality control (QC) records, lack of QC documentation and interview with the technical consultant (TC-1), the laboratory failed to establish the statistical parameters for unassayed control materials used by the laboratory for Coagulation testing. Findings include: 1. The laboratory performs Coagulation testing on the Hemochron analyzer. It is the practice of the laboratory to utilize commercially available control material. The laboratory performs the following tests: Protime (PT/INR). 2. Review of QC logs for PT/INR records indicated that the laboratory utilized a previously tested patient specimen instead of the commercially available Control Level 1 on April 29, 2022. 3. No documentation was presented for review to indicate the laboratory established the criteria for acceptability of the patient specimen used by the laboratory as a substitute for control level 1 on April 29, 2022. 4. At 3:20 PM on May 16, 2023, the TC-1 interviewed confirmed that the laboratory failed to establish the criteria for acceptability of control materials used on the Hemochron analyzer on April 29, 2022. 5. Approximately 1 patient test for PT/INR was performed on April 29, 2022. D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of Quality Control (QC) documentation and interview with the technical supervisor (TS-1), the laboratory failed to test staining materials for intended reactivity to ensure predictable staining characteristics for testing performed in the specialty of Hematology. Findings include: 1. The laboratory performs testing in the specialty of Hematology, with an approximate annual test volume of 23,960. 2. It is the practice of the laboratory to perform a manual differential on blood smears using a differential stain (Wright Stain), if the specimen meets certain criteria established in the laboratory's procedure manual. 3. Review of the Daily Wright Stain Check log from April 2022 used by the laboratory to record the Wright Stain acceptability failed to indicate the acceptability of the Wright Stain material on April 2, April 16, April 23 and April 30, 2022. 4. The TS-1 interviewed on May 16, 2023 at 1:30 PM confirmed the laboratory failed to test staining materials for intended reactivity to ensure -- 5 of 8 -- predictable staining characteristics in April 2022 as indicate above. 5. The number of patients tested with this stain could not be determined at the time of the survey. D5545 HEMATOLOGY CFR(s): 493.1269(b)(d) (b) For all nonmanual coagulation test systems, the laboratory must include two levels of control material each 8 hours of operation and each time a reagent is changed. (d) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of Quality Control (QC) records and interview with the Technical Consultant (TC-1), the laboratory failed to perform and document two levels of control material each 8 hours of operation for Coagulation testing performed in the specialty of Hematology. Findings include: 1. The laboratory performs Coagulation testing on the Hemochron analyzer in the specialty of Hematology. The laboratory's hours of operation are reported as 24 hours a day, 7 days a week. 2. Review of the laboratory's QC logs indicated the laboratory failed to perform two levels of control material each 8 hours of operation for Protime/INR (PT/INR) testing for the following dates in April 2022: April 1st - 9th, April 12th, April 13th, April 15 - 21, and April 29th. 3. Review of the laboratory's QC logs indicated the laboratory failed to perform two levels of control material each 8 hours of operation for Activated Partial Thromboplastin Clotting Time (APTT) testing for the following dates in April 2022: April 4th - 9th, April 12th, April 13th, April 16, April 18 - 19th. 4. The TC-1 interviewed on May 16, 2023 at 3:18 PM confirmed the laboratory failed to perform two levels of control material each 8 hours of operation for PT/INR and APTT during April 2022. 5. The laboratory performed 58 PT/INR tests on the dates indicated above (see #2). 6. The laboratory performed 22 APTT tests on the dates indicated above (see #3). D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on review of Quality Assessment (QA) policies and procedures, analytic test records, and interview with the technical supervisor (TS-1), the laboratory's established QA policies and procedures failed to monitor, assess and, when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. Findings include: 1. The laboratory performs a monthly QA summary report for each department (instrument/test system) performed by the laboratory. 2. The QA summary report reviewed during the survey for April 2022 for "Hemochron Coagulation" failed to identify problems found with the frequency of Coagulation Control material performed by the laboratory, see D5445 for findings. 3. The QA summary report reviewed during the survey for April 2022 for "Hemochron Coagulation" failed to identify problems found with using previously tested patient -- 6 of 8 -- specimens as control materials, in which the laboratory failed to establish the the criteria for acceptability of these control materials, see D5469 for findings. 4. The TS- 1 interviewed on May 16, 2023 at 3:50 PM confirmed the laboratory's QA processes were not effective at monitoring, identifying and correcting problems associated with the analytic systems. D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on lack of performance evaluation documentation and interview with the technical consultant (TC-1), the technical consultant failed to evaluate and document the performance of one testing personnel, at least semiannually during the first year the individual tested patient specimens. Findings include: 1. No evidence of a semiannual competency evaluation was presented for review for one out of one testing personnel who began testing in the specialties of Microbiology, Hematology and Chemistry in January 2022 2. The TC-1 interviewed on May 16, 2023 at 11:55 AM confirmed the laboratory failed to document a semiannual competency evaluation for one testing personnel as indicated above. D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: The Condition of Laboratory Director was found to be not met based on the failure to provide overall management and direction as evidenced by D6089 - ensuring that proficiency testing samples are tested as required under Subpart H and D6093 - failure to ensure quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. D6089 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(i) The laboratory director must ensure the proficiency testing samples are tested as required under subpart H of this part. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, it was determined that the laboratory director failed to ensure that PT samples are tested in a manner that results in successful participation in a proficiency testing program for the regulated analytes, AST(SGOT) and Phenytoin. See D2016 and D6076 for findings. -- 7 of 8 -- D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on review of quality control records and control procedures, the laboratory director failed to ensure that quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. See D5469 and D5545 for findings. D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on lack of documentation of a semi-annual competency evaluation for one testing personnel and interview with the technical supervisor (TS-1), the technical supervisor failed to evaluate and document the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. Findings include: 1. No evidence of a semi-annual competency evaluation was presented for review for one out of one testing personnel who began testing in the specialties of Microbiology, Hematology and Immunohematology in January 2022. 2. The TS-1 interviewed on May 16, 2023 at 11: 55 AM confirmed that the technical supervisor failed to document a semi-annual competency evaluation for the testing personnel indicated above. -- 8 of 8 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 12, 2021

Survey Type: Special

Survey Event ID: QM3Z11

Deficiency Tags: D2094 D6000 D2016 D2096 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Proficiency Testing (PT) reports for 2020 and 2021 sent to the State Agency by the PT provider, the laboratory failed to successfully participate in a PT program for the regulated analytes, pH Blood Gas, PO2 Blood Gas and PCO2 Blood Gas, under the specialty of Chemistry. Findings include: 1. The laboratory's PT performance was unsatisfactory for the second event of 2020 for the regulated analyte, pH Blood Gas, with a score of 0%. 2. The laboratory's PT performance was unsatisfactory for the first event of 2021 for the regulated analyte, pH Blood Gas, with a score of 60%. 3. The laboratory's PT performance was unsatisfactory for the second event of 2020 for the regulated analyte, PO2 Blood Gas, with a score of 0%. 4. The Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- laboratory's PT performance was unsatisfactory for the first event of 2021 for the regulated analyte, PO2 Blood Gas, with a score of 60%. 5. The laboratory's PT performance was unsatisfactory for the second event of 2020 for the regulated analyte, PCO2 Blood Gas, with a score of 0%. 6. The laboratory's PT performance was unsatisfactory for the first event of 2021 for the regulated analyte, PCO2 Blood Gas, with a score of 60%. D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on the information furnished to the State Agency by the Proficiency Testing (PT) provider, it could not be determined if the laboratory underwent training and technical assistance and if remedial action was taken to correct the PT failure for the analytes, pH Blood Gas, PO2 Blood Gas and PCO2 Blood Gas, for the 2nd testing event of 2020 and 1st testing event of 2021. See D2016 for findings. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analytes, pH Blood Gas, PO2 Blood Gas and PCO2 Blood Gas, for the 2nd event of 2020 and 1st event of 2021 resulting in unsuccessful PT performance. See D2016 for findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: The Condition of Laboratory Director was found to be not met based on the failure to provide overall management and direction as evidenced by D6016 - ensuring that the proficiency testing samples are tested as required under Subpart H. -- 2 of 3 -- D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, it was determined that the laboratory director failed to ensure that PT samples are tested in a manner that results in successful participation in a proficiency testing program for the regulated analytes, pH Blood Gas, PO2 Blood Gas and PCO2 Blood Gas. See D2016 and D6000 for findings. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 2, 2021

Survey Type: Special

Survey Event ID: B0G811

Deficiency Tags: D2094 D2116 D6000 D2016 D2096 D2118 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Proficiency Testing (PT) reports for 2019 and 2020 sent to the State Agency by the PT provider, the laboratory failed to successfully participate in a PT program for the regulated analyte, (A) Chloride and (B) Digoxin, under the specialty of Chemistry. Findings include: A1. The laboratory's PT performance was unsatisfactory for the 1st event of 2020 for the regulated analyte, Chloride, with a score of 40%. A2. The laboratory's PT performance was unsatisfactory for the 2nd event of 2020 for the regulated analyte, Chloride, with a score of 0%. * A3. The laboratory's PT performance was unsatisfactory for the 3rd event of 2020 for the regulated analyte, Chloride, with a score of 60%. ** A4. *Unsatisfactory participation Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- in the 1st and 2nd events of 2020 (two consecutive testing events) for the regulated analyte, Chloride, constitutes an initial unsuccessful PT performance. A5. **Unsatisfactory participation in the 2nd and 3rd events of 2020 (two consecutive testing events) for the regulated analyte, Chloride, constitutes an unsuccessful PT performance and a subsequent unsuccessful PT to the initial unsuccessful PT as outlined above in # A4. B1. The laboratory's PT performance was unsatisfactory for the 2nd event of 2019 for the regulated analyte, Digoxin, with a score of 60%. B2. The laboratory's PT performance was unsatisfactory for the 1st event of 2020 for the regulated analyte, Digoxin, with a score of 60%. * B3. The laboratory's PT performance was unsatisfactory for the 2nd event of 2020 for the regulated analyte, Digoxin, with a score of 0%. ** B4. *Unsatisfactory participation in the 2nd event of 2019 and 1st event of 2020 (two out of three consecutive testing events) for the regulated analyte, Digoxin, constitutes an initial unsuccessful PT performance. B5. **Unsatisfactory participation in the 1st and 2nd events of 2020 (two consecutive testing events) for the regulated analyte, Digoxin, constitutes an unsuccessful PT performance and a subsequent unsuccessful PT to the initial unsuccessful PT as outlined above in # B4. D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on the information furnished to the State Agency by the Proficiency Testing (PT) provider, it could not be determined if the laboratory underwent training and technical assistance and if remedial action was taken to correct the PT failure for the analyte, Chloride, for the 1st, 2nd and 3rd testing event of 2020. See D2016 for findings. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, Chloride, for the 1st, 2nd and 3rd event of 2020 resulting in subsequent unsuccessful PT performance. See D2016 for findings. D2116 TOXICOLOGY CFR(s): 493.845(e) -- 2 of 4 -- (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on information the Proficiency Testing (PT) provider furnishes to the State Agency for 2019 and 2020, it could not be determined if the laboratory underwent training and technical assistance and if remedial action was taken to correct the PT failures for the regulated analyte, Digoxin, for the 2nd event of 2019, 1st event of 2020 and 2nd event of 2020. See D2016 for findings. D2118 TOXICOLOGY CFR(s): 493.845(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, Digoxin, for the 2nd event of 2019, 1st event of 2020 and 2nd event of 2020 resulting in subsequent unsuccessful PT performance. See D2016 for findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: The Condition of Laboratory Director was found to be not met based on the failure to provide overall management and direction as evidenced by D6016 - ensuring that the proficiency testing samples are tested as required under Subpart H. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; -- 3 of 4 -- This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, it was determined that the laboratory director failed to ensure that PT samples are tested in a manner that results in successful participation in a proficiency testing program for the regulated analytes, Chloride and Digoxin. See D2016 and D6000 for findings. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 15, 2020

Survey Type: Special

Survey Event ID: 6RC011

Deficiency Tags: D2116 D6000 D2016 D2118 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Proficiency Testing (PT) reports for 2019 and 2020 sent to the State Agency by the PT provider, the laboratory failed to successfully participate in a PT program for the regulated analyte, Digoxin, under the sub-specialty of Toxicology. Findings include: 1. The laboratory's PT performance was unsatisfactory for the 2nd event of 2019 for the regulated analyte, Digoxin, with a score of 60%. 2. The laboratory's PT performance was unsatisfactory for the 1st event of 2020 for the regulated analyte, Digoxin, with a score of 60%. D2116 TOXICOLOGY Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- CFR(s): 493.845(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on information the Proficiency Testing (PT) provider furnishes to the State Agency for 2019 and 2020, it could not be determined if the laboratory underwent training and technical assistance and if remedial action was taken to correct the PT failures for the analyte, Digoxin. See D2016 for findings. D2118 TOXICOLOGY CFR(s): 493.845(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, Digoxin, for the 2nd event of 2019 and 1st event of 2020 resulting in unsuccessful PT performance. See D2016 for findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: The Condition of Laboratory Director was found to be not met based on the failure to provide overall management and direction as evidenced by D6016 - ensuring that the proficiency testing samples are tested as required under Subpart H. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, it was determined that the laboratory director failed to ensure that PT samples are tested in a manner that results in successful participation in a proficiency testing program for the regulated analyte, Digoxin. See D2016 and D6000 for findings. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 20, 2020

Survey Type: Standard

Survey Event ID: 702V11

Deficiency Tags: D5291 D5413

Summary:

Summary Statement of Deficiencies D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: Based on review of Proficiency Testing (PT) records and interview with the facility personnel, the laboratory failed to document

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 6, 2018

Survey Type: Special

Survey Event ID: TV6F11

Deficiency Tags: D2016 D2096 D6016 D2094 D6000

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of Proficiency Testing (PT) reports for 2018 sent to the State Agency by the PT provider, the laboratory failed to successfully participate in a PT program for the regulated analyte, Chloride, under the specialty of Chemistry. Findings include: 1. The laboratory's PT performance was unsatisfactory for the 1st event of 2018 for the regulated analyte, Chloride, with a score of 60%. 2. The laboratory's PT performance was unsatisfactory for the 3rd event of 2018 for the regulated analyte, Chloride, with a score of 20%. D2094 ROUTINE CHEMISTRY Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on the information furnished to the State Agency by the Proficiency Testing (PT) provider, it could not be determined if the laboratory underwent training and technical assistance and if remedial action was taken to correct the PT failure for the analyte, Chloride, for the 1st and 3rd testing event of 2018. See D2016 for findings. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, the laboratory failed to achieve satisfactory performance for the regulated analyte, Chloride, for the 1st and 3rd event of 2018 resulting in unsuccessful PT performance. See D2016 for findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: The Condition of Laboratory Director was found to be not met based on the failure to provide overall management and direction as evidenced by D6016 - ensuring that the proficiency testing samples are tested as required under Subpart H. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on information furnished to the State Agency by the Proficiency Testing (PT) provider, it was determined that the laboratory director failed to ensure that the PT samples are tested in a manner that results in successful participation in a proficiency testing program for the regulated analyte, Chloride. See D2016 for findings. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 25, 2018

Survey Type: Standard

Survey Event ID: 16ZB11

Deficiency Tags: D5445 D5791 D5805 D5543 D5801

Summary:

Summary Statement of Deficiencies D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on lack of quality control (QC) documentation and interview with the facility personnel, the laboratory failed to perform and document control procedures using the number and frequency as required for testing performed on the Alere analyzer. Findings include: 1. The laboratory began D-dimer, CK-MB and Troponin testing under the specialty of Hematology and Chemistry using the Alere analyzer on April 4, 2017. On the date of the survey, April 25, 2018, the laboratory's quality control procedure consisted of performing two levels of external control material, once each month and/or each new shipment or lot of test reagents. 2. No QC documentation was provided for review during the survey to indicate the laboratory performed two levels of external quality control material of different concentrations each day of patient testing as required since January 1, 2016. The laboratory had not implemented an Individualized Quality Control Plan (IQCP) for this test system. 4. The facility personnel confirmed that the laboratory did not perform and document controls as required and confirmed that the laboratory had not implemented an Individualized Quality Control Plan (IQCP) for testing performed on the Alere analyzer. 5. The number of patients tested on the Alere analyzer could not be determined at the time of the survey. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D5543 HEMATOLOGY CFR(s): 493.1269(a)(d) (a) For manual cell counts performed using a hemocytometer-- (a)(1) One control material must be tested each 8 hours of operation; and (a)(2) Patient specimens and control materials must be tested in duplicate. (d) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of patient test records and interview with the testing personnel it was determined that the laboratory failed to document duplicate cell counts using a hemocytometer. Findings include: 1. The laboratory performs a manual cell count on Cerebrospinal Fluid (CSF) using a hemocytometer and uses a worksheet to record the count. 2. Review of the laboratory's worksheet for patient# 1203212 on 10/27/17 indicated the laboratory performed a CSF count but did not document the count in duplicate. 3. The testing personnel confirmed that the counts are performed in duplicate but the laboratory failed to document both counts. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on review of Quality Assessment (QA) documentation and policies and interview with the facility personnel, the laboratory failed to have written policies and procedures for an ongoing mechanism to monitor, assess, and correct problems identified in the analytic systems. Findings include: 1. No documentation was presented for review during the survey to indicate the laboratory monitored or identified problems with analytic activities, including but not limited to, quality control procedures for the Alere analyzer. See D5445 for findings. 2. The facility personnel confirmed that the laboratory did not have a system in place at the time of the survey to monitor specific areas of the analytic systems as indicated above. D5801 TEST REPORT CFR(s): 493.1291(a) The laboratory must have an adequate manual or electronic system(s) in place to ensure test results and other patient-specific data are accurately and reliably sent from the point of data entry (whether interfaced or entered manually) to final report destination, in a timely manner. This includes the following: (a)(1) Results reported from calculated data. (a)(2) Results and patient-specific data electronically reported to network or interfaced systems. (a)(3) Manually transcribed or electronically transmitted results and patient-specific information reported directly or upon receipt from outside referral laboratories, satellite or point-of-care testing locations. This STANDARD is not met as evidenced by: -- 2 of 3 -- Based on review of patient test reports and interview with the facility personnel, the laboratory failed to have a system in place to ensure the accuracy of test results that are manually entered into the laboratory's information system (LIS). Findings include: 1. The laboratory performs patient testing in the specialty of Microbiology, Chemistry, Hematology and Immnuohematology, with an approximate annual test volume of 29,740. It is the practice of the laboratory to manually enter test results into the LIS for the following tests: KOH, Wet Mount, Gram Stain, ABO/Rh, and testing performed on the I-stat analyzer (Arterial Blood Gas and PT/INR). 2. No documentation was presented for review during the survey to indicate the laboratory has a system in place to ensure the accuracy of patient test results that are manually entered into the LIS. 3. The facility personnel confirmed that the laboratory did not have a system in place to verify the accuracy of the patient test results that are manually entered by the testing personnel into the LIS. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on review of patient test reports and interview with the facility personnel, the laboratory failed to include on the test report the laboratory address where the testing was performed. Findings include: 1. The laboratory performs patient testing in the specialty of Microbiology, Chemistry, Hematology and Immnuohematology, with an approximate annual test volume of 29,740. 2. Six out of six test reports reviewed during the survey were missing the laboratory address where the testing was performed. 3. The facility personnel confirmed that the laboratory address where the testing was performed was not indicated on the test reports referenced above. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access