Corazon C Medina, Md Inc

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 05D0856340
Address 1751 W Romneya Dr, Ste H, Anaheim, CA, 92801
City Anaheim
State CA
Zip Code92801
Phone(714) 563-2114

Citation History (2 surveys)

Survey - June 12, 2025

Survey Type: Standard

Survey Event ID: J9QS11

Deficiency Tags: D2087 D2122 D2099 D6036

Summary:

Summary Statement of Deficiencies D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) (a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on the surveyor's review of the laboratory's policy and procedure, American Association of Bioanalysts - Medical Laboratory Evaluation (AAB-MLE) proficiency testing (PT) records, and interviews with the technical consultant (TC) and testing personnel (TP), it was determined that the laboratory failed to attain at least 80 percent of the acceptable score in Routine Chemistry for the Magnesium (Mg), Aspartate Aminotransferase (AST), and Albumin analytes. The findings include: 1. The surveyor reviewed the PT records wherein AAB-MLE reported unsatisfactory scores for Mg, AST and Albumin analytes. The results were as follows: a. Mg PT analyte in third event of 2023 (Q3-2023), Overall score: 60% Specimen Reported Expected 11 4.1 3.1 - 5.2 12 *3.4 1.5 - 2.5 13 *34.7 2.6 - 4.4 14 3.2 2.4 - 4.0 12 2.9 2.1 - 3.5 b. AST PT analyte in the first event of 2024 (Q1-2024), Overall score: 20% Specimen Reported Expected 01 15 10.0 - 15.0 02 *261 162.0 - 244.0 03 *197 122.0 - 182.0 04 *40 26.0 - 39.0 05 *375 223.0 - 335.0 c. Albumin PT analyte in the second event of 2024 (Q2-2024), Overall score: 60% Specimen Reported Expected 06 4.5 4.0 - 4.9 07 3.2 2.9 - 3.5 08 *1.6 1.7 - 2.1 09 *3.5 2.6 - 3.2 10 2.3 2.0 - 2.5 Legend: * = unsatisfactory score reported 2. The TC and TP affirmed by interviews on June 12, 2025, at approximately 9:50 a.m. that the laboratory obtained the PT unsatisfactory scores mentioned in statement #1. 3. According to the laboratory's testing declaration submitted on the day of the survey, the laboratory performed approximately 8,000 patient test samples for Routine Chemistry including Mg, AST, and Albumin analytes during the time the laboratory received an unsatisfactory proficiency testing scores. Thus, the accuracy and reliability of patient test reported cannot be determined. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D2099 ENDOCRINOLOGY CFR(s): 493.843(b) (b) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on the surveyor's review of the American Association of Bioanalysts - Medical Laboratory Evaluation (AAB-MLE) proficiency testing (PT) reports and interviews with the technical consultant (TC) and testing personnel (TP), it was determined that the laboratory failed to attain a score of at least 80 percent in Endocrinology for Thyroid-Stimulating Hormone (TSH) for the first event of 2025 (Q1-2025). The findings include: 1. The laboratory obtained a score of 60% for the TSH analyte as reported by AAB-MLE PT for the Q1-2025 event. 2. The TC and TP affirmed on June 12, 2025, at approximately 10:30 a. m. that the laboratory obtained the unsatisfactory proficiency score as mentioned on statement#1 for the TSH analyte. 3. Based on the laboratory's annual test volume declaration signed by the laboratory director on 6/11 /2025, the laboratory analyzed and reported approximately 1,000 Endocrinology patient tests which included the TSH analyte. The realiability and quality of patient tests reported cannot be assured. D2122 HEMATOLOGY CFR(s): 493.851(b) (b) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on the surveyor's review of the laboratory's American Association of Bioanalysts - Medical Laboratory Evaluation (AAB-MLE) proficiency testing (PT) records and interviews with the technical consultant (TC) and testing personnel (TP); it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for Hematology on the first event of 2024 (Q1-2024). The findings include: 1. The AAB-MLE proficiency program reported an unsatisfactory score of 60% for the Hematocrit analyte for Q1-2024 event. 2. The TC and TP affirmed by interview on June 12, 2025, at approximately 10:30 a.m. that the laboratory received the unsatisfactory score as mentioned in statement #1. 3. The reliability and quality of Hematology results reported could not be assured when the laboratory failed to attain overall scores of at least 80% in the PT event. 4. According to the testing declaration form submitted at the time of survey, the laboratory performed and reported 2,500 patient tests in Hematology annually including the time when the unsatisfactory PT scores were obtained. D6036 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413 The technical consultant is responsible for the technical and scientific oversight of the laboratory. The technical consultant is not required to be onsite at all times testing is performed; however, he or she must be available to the laboratory on an as needed basis to provide consultation, as specified in paragraph (a) of this section. -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on the surveyor's review of the proficiency testing results from the American Association of Bioanalysts - Medical Laboratory Evaluation, and interviews with the technical consultant (TC) and testing personnel on June 12, 2025; this deficient practice is cited due to failure of the TC to provide technical and scientific oversight of the laboratory. The findings include: 1. Unsatisfactory proficiency testing score for Routine Chemistry. See D2087. 2. Unsatisfactory proficiency testing score for Endocrinology. See D2099. 3. Unsatisfactory proficiency testing score for Hematology. See D2122. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 17, 2018

Survey Type: Standard

Survey Event ID: A9KK11

Deficiency Tags: D6021 D5439

Summary:

Summary Statement of Deficiencies D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on review of the laboratory records, and interview with the technical consultant and the testing personnel, it was determined that the laboratory failed to follow the manufacturer's calibration verification instructions and performed calibration verification at least once every 6 months including at least a minimal (or zero ) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system. The findings Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- included: a. The laboratory performed calibration verifications for its chemistry instrument, ACE Alera by Alpha Wassermann, on 9/17/2017 and on 9/6/2018. b. The laboratory failed to meet the CLIA requirements and follow the rules to perform calibration verification procedures every 6 month. c. The laboratory testing personnel affirmed (10/17/18 @ 13:10) that the laboratory did not follow the CLIA rules to perform calibration verification for chemistry instruments, where the analyte useing less than three levels of calibrators in the laboratory's routine calibration procedures must perform calibration verification for that analyte every 6 months. D6021 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that quality assessment programs are established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on review of the laboratory's records, and interview with the technical consultant, and the testing personnel, it was determined that the laboratory director failed to ensure that quality assessment programs were established and maintained to assure the quality of laboratory services provided. The findings included: See D-5439 -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access