Coreplus Servicios Clinicos Y Patologicos,Llc

CLIA Laboratory Citation Details

2
Total Citations
11
Total Deficiencyies
11
Unique D-Tags
CMS Certification Number 40D0994189
Address Ave Sanchez Vilella Esq Pr-190, Suite #2-6, Carolina, PR, 00984
City Carolina
State PR
Zip Code00984
Phone(855) 711-2673

Citation History (2 surveys)

Survey - October 18, 2022

Survey Type: Standard

Survey Event ID: 6CTK11

Deficiency Tags: D3037 D5805 D5209 D6088 D2004 D5311 D6079

Summary:

Summary Statement of Deficiencies D2004 ENROLLMENT CFR(s): 493.801(a)(3) For each specialty, subspecialty and analyte or test, participate in one approved proficiency testing program or programs, for one year before designating a different program and must notify CMS before any change in designation; This STANDARD is not met as evidenced by: Based on Proficiency Testing Program records review ( year 2022), and laboratory staff interview, it was determined that the laboratory failed to enroll in an HHS approved Proficiency Testing Program for Mycology- Dermatophyte Multiplex PCR assay in the MagNa Pure 96 analyzer. The findings includes: a. The laboratory was enrolled in the Puerto Rico Proficiency Testing Program and College of American Pathologists (CAP) proficiency program. b. On October 18, 2022 at 12:00 pm the Puerto Rico proficiency testing program and CAP proficiency program were reviewed (year 2022). c. Proficiency Testing Program for Mycology- Dermatophyte Multiplex PCR assay in the MagNa Pure 96 analyzer was requested. d. On October 18, 2022 at 1: 05pm the laboratory staff confirmed that the laboratory failed to participate in Proficiency Testing Program for Mycology- Dermatophyte Multiplex PCR assay in the MagNa Pure 96 analyzer. The laboratory processed and reported one (1) patient specimens year 2022. D3037 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(4) Proficiency testing records. Retain all proficiency testing records for at least 2 years. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- Based on College of American Pathologist (CAP) Proficiency Testing Program records review and cytologist supervisor interview on October 18, 2022 at 11:55 AM, it was determined that the laboratory failed to retain the papanicolaou (PAP) proficiency testing records for at least 2 years. The findings include: 1. The laboratory use the CAP proficiency testing program for the PAP proficiency testing since 2021. 2. On October 18, 2022 at 11:00 AM, the laboratory did not have available the CAP's Laboratory transcript with the score of the PAP proficiency testing evaluated during the year 2021. 3. On October 18, 2022 at 11:55 AM, the cytologist supervisor confirmed that the CAP transcript report for the year 2021 was not available in the laboratory. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on personnel records review and laboratory cytotechnologist supervisor interview, it was determined that the laboratory failed to follow the established schedule for pathologist clinical consultant competence evaluation. The findings include: a. On October 18, 2022 at 2:00pm the personel record was reviewed. The laboratory schedule for pathologist clinical consultant competence evaluation showed that it must be performed every year. b. The laboratory did not perform the following competence evaluations since year 2021: Pathologist clinical consultant- #14829, Pathologist clinical consultant-# 15223. c. On October 18, 2022 at 2:45PM the cytotechnologist supervisor confirmed that the laboratory fail to performed the competence evaluation fo the Pathologist clinicaal consultant. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: Based on lack of written procedures; lack of temperature record of the transport cooler, random review of the patient's samples referral and laboratory staff interview; it was determined that the laboratory failed to establish and follow a written polices for the specimen transportation and specimen referral. The findings include: a. The laboratory refers patient samples to CorePlus Servicios Clinicos y Patologicos Ponce. b. On October 18, 2022 at 3:28 PM a record of temperature of the transport cooler and written procedures of specimen transportation and specimen referral was requested. However, the CorePlus Servicios Clinicos y Patologicos Carolina did not have any written protocol for the referral and transportation of patient's samples, neither had records of the temperatures of the transport cooler. c. Random review of the patient's -- 2 of 4 -- samples referred to CorePlus Servicios Clinicos y Patologicos Ponce, showed that the laboratory delivered a total of 8,260 samples (February 2021= 1,003; March 2021= 1,119; September 2021= 1,803; February 2022= 1,925; March 2022= 2,410). d. The technical laboratory staff confirmed on October 18, 2022 at 3:35 PM, that the laboratory did not have the written procedures and a record of temperature for the transport cooler. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on laboratory test reports records (year 2022) review and laboratory supervisor interview, it was determined that the laboratory failed to include in the test report that the Mycology- Dermatophyte Multiplex PCR assay test performed in the MagNa Pure 96 analyzer, is a laboratory developed test (LDT) The findings include: a. The laboratory develop the test for mycology- Dermatophyte Multiplex PCR assay in the MagNa Pure 96 analyzer. The test was validated and approved by the Laboratory director on April 20, 2022. b. On October 18, 2022 at 11:58 AM the laboratory test reports for Mycology- Dermatophyte Multiplex PCR assay in the MagNa Pure 96 were reviewed. c. The laboratory test report showed that the LDT statement was not included. d. The laboratory supervisor confirmed on October 18, 2022 at 12:05 PM, that the test report did not include the LDT statement. The laboratory process and report one (1) patient sample (year 2022) D6079 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(a)(b) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, record and report test results promptly, accurately and proficiently, and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical supervisor, clinical consultant, general supervisor, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications under 493.1447, 493.1453, 493.1459, and 493.1487 respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. This STANDARD is not met as evidenced by: 1- Based on College of American Pathologist (CAP) Proficiency Testing Program records review and cytologist supervisor interview on October 18, 2022 at 11:55 AM, it was determined that the laboratory director failed to ensure that the laboratory retain -- 3 of 4 -- the proficiency testing records for at least 2 years. Refer to D 3037 (The laboratory failed to retain the papanicolaou (PAP) proficiency testing records for at least 2 years). 2- Based on personnel records review, written procedures, and laboratory general supervisor interview, it was determined that the laboratory director failed to ensure. Refer to D 5209 (The laboratory fail to perform a evaluation of competence for pathologist clinical consultant). Refer to D 5311 (The laboratory fail to establish a written procedure for the referral specimen and lack temperature record of transport cooler). 3- Based on test report review for Mycology- Dermatophyte Multiplex PCR assay in the magna Pure 96 analyzer, the laboratory failed to include that the test was a Laboratory develop test (LDT) statement. Refer to D 5805 D6088 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4) The laboratory director must ensure that the laboratory is enrolled in an HHS- approved proficiency testing program for the testing performed. This STANDARD is not met as evidenced by: Based on P. R. Proficiency Testing Program records review, College of American Pathologist and interview with the laboratory supervisor on October 18, 2022 at 1:05 PM, it was determined that the laboratory director failed to ensure that the laboratory is enrolled in an HHS-approved proficiency testing program for the following test: Dermatophyte Multiplex PCR assay in the Magna Pure 96 analyzer. Refer to D 2004 -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 25, 2018

Survey Type: Standard

Survey Event ID: LWHL11

Deficiency Tags: D6093 D5477 D6177 D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on clinical cytogenetics quality control records review from December 29, 2017 to October 25, 2018 and laboratory testing personnel interview on October 25, 2018 at 1:55 PM, it was determined that the laboratory failed to follow manufacturer's instructions for the fluorescence microscope preventive maintenance (Olympus BX61). The findings include: 1. The laboratory did not perform the mercury lamp usage time of the fluorescence microscope preventive maintenance since December 29, 2017 to October 22, 2018. 2. The laboratory testing personnel confirmed on October 25, 2018, that those preventive maintenance did not perform since December 29, 2017. 3. The laboratory perform 97 patients tests from December 29, 2017 to October 25, 2018. D5477 CONTROL PROCEDURES CFR(s): 493.1256(e)(4)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (4) Before, or concurrent with the initial use-- (e)(4)(i) Check each batch of media for sterility if sterility is required for testing; (e)(4)(ii) Check each batch of media for its ability to support growth and, as appropriate, select or inhibit specific organisms or produce a biochemical response; and (e)(4)(iii) Document the physical characteristics of the media when compromised and report any deterioration in the media to the manufacturer. (g) The laboratory must document all control procedures performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on bacteriology culture media quality control records review from January 3, 2017 to October 25, 2018 and laboratory testing personnel interview on October 25, 2018 at 11:22 AM, it was determined that the laboratory failed to check each batch of cultures media plates used at the laboratory for selectivity and or inhibition and biochemical response since January 3, 2017. The findings include: 1. Review of the bacteriology culture media quality control records showed that the following agar plates were being used: Blood Agar 5 % (BA). 2. From January 3, 2017, the laboratory received the following: Media lot # open date expiration date 1. Blood Agar 17009 January 30, 2017 04/09/2017 2. Blood Agar 17023 March 4, 2017 04/25 /2017 3. Blood Agar 17052 May 1, 2017 05/22/2017 4. Blood Agar 17129 July 10, 2017 08/07/2017 5. Blood Agar 17178 August 14, 2017 09/25/2017 6. Blood Agar 17199 September 18, 2017 10/16/2017 7. Blood Agar 17242 October 10, 2017 11/25 /2017 8. Blood Agar 404025 December 04, 2017 01/25/2018 9. Blood Agar 415522 December 26, 2017 02/19/2018 10. Blood Agar 407603 January 15, 2018 03/28/2018 11. Blood Agar 409791 March 14, 2018 05/02/2018 12. Blood Agar 411522 April 09, 2018 05/13/2018 13. Blood Agar 416265 June 11, 2018 08/13/2018 14. Blood Agar 419034 August 06, 2018 09/24/2018 15. Blood Agar 420710 September 04, 2018 10 /23/2018 3. The laboratory processed 12861 patient's cultures samples from January 3, 2017. 4. The laboratory testing personnel stated on October 25, 2018, that the laboratory did not perform the evaluation of the ability to support growth was performed from January 3, 2017. D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on quality control records review and laboratory testing personnel interview on October 25, 2018 at 1:55 PM, it was determined that laboratory director failed to ensure compliance with the requirements for analytic systems. The finding includes: 1. The laboratory director did not assure that the laboratory: a. follow manufacturer's instructions for the fluorescence microscope preventive maintenance (Olympus BX61). Refer to D5429. b. to check each batch of cultures media plates used at the laboratory for selectivity and or inhibition and biochemical response since January 3, 2017. Refer to 5477. D6177 TESTING PERSONNEL RESPONSIBILITIES CFR(s): 493.1495(b)(3) Each individual performing high complexity testing must adhere to the laboratory's quality control policies, document all quality control activities, instrument and procedural calibrations and maintenance performed. This STANDARD is not met as evidenced by: Based on quality control records review and laboratory testing personnel interview on -- 2 of 3 -- October 25, 2018 at 1:58 PM, it was determined that testing personnel failed to follow quality control procedures. The finding includes: 1. The laboratory testing personnel failed the following quality control procedures: a. follow manufacturer's instructions for the fluorescence microscope preventive maintenance (Olympus BX61). Refer to D5429. b. to check each batch of cultures media plates used at the laboratory for selectivity and or inhibition and biochemical response since January 3, 2017. Refer to 5477. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access