Cvi Ambulatory Surgery Center

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 10D2231440
Address 6547 Sw State Road 200, Ocala, FL, 34476
City Ocala
State FL
Zip Code34476
Phone(352) 355-3300

Citation History (2 surveys)

Survey - August 1, 2023

Survey Type: Standard

Survey Event ID: JM1S11

Deficiency Tags: D0000 D5791

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was conducted on August 1, 2023 at Cvi Ambulatory Surgery Center, a clinical laboratory located in Ocala, Florida. Cvi Ambulatory Center was found to NOT be in compliance with 42 CFR 493, requirements for clinical laboratories. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on record review and staff interview, it was determined that the laboratory's quality assessment (QA) process failed to monitor and correct issues with failed proficiency testing scores for a non regulated analyte for two of three Hematology testing events in 2022. The findings include: Record review of the American Proficiency Institute (API) test events for 2022 showed the following: *2022 1st Event Hematology for the unregulated analyte Activated Clotting Time (ACT) failed with a score of 50% *2022 2nd Event Hematology for the unregulated analyte Activated Clotting Time (ACT) failed with a score of 50% There was no documentation of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 17, 2023

Survey Type: Special

Survey Event ID: 9G3P11

Deficiency Tags: D0000 D2130 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D0000 A desk review survey of the laboratory's proficiency test results was performed on January 17, 2023 for CVI Ambulatory Surgery Center laboratory. CVI Ambulatory Surgery Center laboratory is not in compliance with the Code of Federal Regulations (CFR), Part 493, Laboratory Requirements. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the laboratory's proficiency testing records for 2022, the laboratory did not have successful performance in proficiency testing for analytes in the specialty of hematology. Refer to D2130.. Findings include: Review of the American Proficiency Institute (API) proficiency testing records and the review of the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Centers for Medicare & Medicaid Services (CMS) 153 and 155 reports, on January 17, 2023 on or about 10:00 AM, showed that the laboratory had unsatisfactory testing scores for the analyte, electronic white blood cell differential for two out of three testing events in 2022. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on the review of the Centers for Medicare & Medicaid Services (CMS) 153 and 155 reports and the laboratory's proficiency testing records, the laboratory did not have successful performance in proficiency testing for analytes in the specialty of hematology. Findings include: On January 17, 2023 on or about 10:00 AM the American Proficiency Institute (API) proficiency testing records and the CMS 153 and 155 reports were reviewed. The review showed that the laboratory failed to achieve satisfactory performance for the analyte, electronic white blood cell differential, as shown below. Event #2, 2022 electronic white blood cell differential- 0% Event #3, 2022 electronic white blood cell differential-0% D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the review of the laboratory's proficiency testing records, the laboratory director failed to ensure that the laboratory maintained a satisfactory score in proficiency testing for analytes found in the specialty of hematology. Findings include: On January 17, 2023, on or about 10:00 AM, the American Proficiency Institute (API) proficiency records and the Centers for Medicare & Medicaid Service (CMS) 153 and 155 reports were reviewed. The review showed that the laboratory had unsatisfactory testing scores for two out of three testing events for the analyte, electronic white blood cell differential, in the specialty of hematology. The laboratory director is responsible for ensuring that the laboratory maintains successful participation in proficiency testing. Refer to D2130. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on the review of the laboratory's proficiency testing scores, the laboratory director failed to ensure that the laboratory performed proficiency testing in such a manner as to achieve and maintain successful participation in proficiency testing for analyte(s) found in the specialty of hematology. Findings Include: The review of the American Proficiency Institute (API) proficiency testing records and the Centers for Medicare & Medicaid Services (CMS) 153 and 155 reports on January 17, 2023, on or about 10:00 AM showed that the laboratory received unsatisfactory proficiency testing scores for two out of three testing events for the analytes shown below. Event #2, 2022 electronic white blood cell differential-0% Event #3, 2022 electronic white blood cell differential-0% -- 3 of 3 --