Cvmc Santaquin Medical Clinic

CLIA Laboratory Citation Details

2
Total Citations
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 46D2139397
Address 210 E Main Street, Santaquin, UT, 84655
City Santaquin
State UT
Zip Code84655
Phone435 445-3619
Lab DirectorBRETT GLEDHILL

Citation History (2 surveys)

Survey - July 10, 2023

Survey Type: Standard

Survey Event ID: MZXV11

Deficiency Tags: D5435 D5435

Summary:

Summary Statement of Deficiencies D5435 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(2) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must: (i) Define a function check protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. (ii) Perform and document the function checks, including background or baseline checks, specified in paragraph (b)(2)(i) of this section. Function checks must be within the laboratory's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on a review of the laboratory's Standard Operating Procedures (SOP), the Thermometer Worksheet, and an interview with the laboratory director (LD), the laboratory failed to perform and document the annual function check on the thermometers in the laboratory refrigerator and freezer during 2022. The refrigerator is used to store the Quality Control (QC) material used on the Sysmex XP-300 Hematology analyzer. The laboratory performs approximately 2040 Hematology tests annually. Findings include: 1. A review of the laboratory's SOP manual at approximately 10:15 AM on 7/10/23 revealed that the SOP titled, "Thermometer Verification," states: "Our thermometers are checked annually against our standard thermometer unless there is a certificate of certification." 2. A certificate of certification was not available for either thermometer in the laboratory refrigerator or freezer at the time of survey. 3. A review of the Thermometer Worksheet at approximately 10:20 AM on 7/10/23 revealed that the thermometers in the laboratory refrigerator and freezer had not been checked against the standard thermometer during 2022. 4. In an interview with the Laboratory Director at approximately 10:25 AM on 7 /10/23, it was confirmed that the thermometers in the laboratory refrigerator and freezer had not been checked against the standard thermometer during 2022. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 13, 2021

Survey Type: Standard

Survey Event ID: 828I11

Deficiency Tags: D5417

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on direct observation and confirmation by staff, the laboratory failed to ensure the heavy metal specimen collection evacuated tube was not used past the expiration date. The laboratory performed approximately 2 specimen collections per year using the dark blue specimen collection tubes. Findings include: 1. Direct observation of specimen collection laboratory area included expired dark blue topped evacuated specimen container tubes in 2 specimen collection containers. The tube labeled the expiration date as 12/31/2020. The date of survey was 01/13/2021. 2. In an interview conducted on 01/13/2021 at approximately 3:00 P.M. staff confirmed the collection tubes were expired and in date replacement tubes were not on the premises. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access